2001-D
Online Video Service
One Year
Medical Research
UV 254nm 280nm
UV Detector
CE, GMP
Solid Adsorbent
Liquid
Liquid Chromatography
Convetional Analytical Column
10~30cm
20~40mm
AIYI
Cartons
83*66*58cm
China
9027201200
Product Description
Nucleic Protein Low Pressure Liquid Chromatography System


Product description
Automatic low pressure liquid chromatographic separation chromatography is a modern analytical experimental instrument engaged in life science research, pharmaceutical determination, agricultural research, chemical, food science, colleges and universities, medical units and other industries.
Features
- It can quickly meet the needs of gel permeation chromatography, affinity chromatography, ion exchange chromatography and other chromatographic analysis.
- Fully automatic partial collector with multiple collection modes,A variety of specifications of the collection tube can be configured.
- Fully automatic tomographic mapping, display and save tomographic data.


Technical parameters
Model | 2001-D-1 Titrate stand |
Configuration | HD-300S Nucleic acid protein detector HL-2F The constant flow pump BSZ-100 partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Flow rate | 2x(0.5-900)ml/h |
speed adjustable range | 0-65r/min |
Partial filling | Manual subassembly and filling. |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-2 Titrate stand |
Configuration | N2000 Nucleic acid protein detector. DHL-B The constant flow pump DBS-100 Partial collector TH-500A Gradient mixer |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-100mV |
Flow rate | 2x(0.5-900)ml/h |
speed adjustable range | 0-65r/min |
Partial filling | 1 sec~ 59 hours 59 min |
Gradient mix | 1000ml gradient |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-3 Titrate stand |
Configuration | HD-3001 Nucleic acid protein detector BT-100SD Constant flow pump DBS-100 Partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-100mV |
Flow rate | 1-14500ml/h |
Speed adjustable range | 0.1-150r/min |
Partial filling | 1 sec~ 9 hours 59 min 59 sec |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-4 Titrate stand |
Configuration | N3000 Nucleic acid protein detector. BT-100SD Constant flow pump CBS-B Partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-250mV |
Program mode | 1-10 mode |
Flow rate | 1-14500ml/h |
speed adjustable range | 0.1-150r/min |
Partial filling | 1 sec~ 59 hours 59 min |
Gradient mix | 1000ml gradient |
Software | Computer graphics, data analysis, calculation and printing. |



No accident shipping term:
DHL: 5-7 working days;
UPS: 7-9 working days;
FedEx: 7-9 working days;
EMS: 25-30 working days;
China Post: Depends on ship to which country;
Sea: Depends on ship to which country

A: We are manufacturer and do both OEM and ODM. We have our own R&D team.
Q2: How to order?
A: Send inquiries → Reply you quotations → Discuss details → Confirm samples →
Deposit → Mass production → Cargo ready → Balance/Delivery → More cooperations.
Q3: What is your payment method ?
A: We accept T/T, Western Union, Paypal and MoneyGram, those depend on specific cases.
Q4: How long is your delivery time?
A: Usually 1-3 working days for products in stock. If we do special offer, it usually takes
4-6 weeks. Also delivery time is according to your quantity of order.
Q5: How to transport?
A: DHL, UPS, FedEx, TNT, EMS, China Post and Sea are available.Also other shipping ways are
available. Please feel free to contact us for other shipping ways.
Q6: How is your warranty service?
A: We do strict test before shipping and guarantee for 365 days. If quality problem you
could send us pictures or video clips about problem. Then we deal with the problem ASAP.
Nucleic Protein Low Pressure Liquid Chromatography System