MS
Single
6 Years
1-350W
85~264VAC 120~373VDC
Series Switching Power Supply
Separate-excited Switching Power Supply
Width Modulation Type
Terminal Power Distribution Equipment
One-way Transmission
PWM
CE, RoHS, ISO, CCC
Nvvv
Paypal\Tt\Western Union\Trade Assurance
Short Circuit Overtemp Overload Overvolt
1A-20A
Ms
Sliver
1PCS
AC-DC
Carton
5V 12V 24V 36V 48V
Industrial Automation
47-63Hz
NVVV
Safety Packaging
199*110*50
Zhejiang, China
Product Description







Safety Packaging
MS-35 35W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 5V | 12V | 24V |
Rated current | 6A | 2.9A | 1.5A | |
Rated power | 30W | 34.8W | 36W | |
Ripple and noise | <50mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >78% | >82% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVACtime <5mA | |||
Leakage current | Input output 220VACtime <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 87*37*60mm (L*W*H) | ||
Net Weight /Gross Weight | 0.15/0.18 KG |
MS-50 50W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 5V | 12V | 24V |
Rated current | 8A | 4.2A | 2.1A | |
Rated power | 40W | 50.4W | 50.4W | |
Ripple and noise | <50mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >78% | >82% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-60 60W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 5A | 2.5A | 1.25A | |
Rated power | 60W | 60W | 60W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-75 75W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 6.25A | 3.12A | 1.56A | |
Rated power | 75W | 75W | 75W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Incput | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >84% | >84% | >84% | |
Working current | <1A 110VAC <0.65A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | vInput output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-100 100W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 8.3A | 4.1A | 2.1A | |
Rated power | 99.6W | 100.8W | 100.8W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <1.8A 110VAC <1.1A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 159*38*98mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3KG |
MS-120 120W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 10A | 5A | 2.5A | |
Rated power | 120W | 120W | 120W | |
Ripple and noise | <120mV | <150mV | <150mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <2A 110VAC <1.3A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 159*38*98mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3KG |
MS-250 250W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 40A | 20.8A | 10.4A | 5.2A | |
Rated power | 200W | 249.6W | 249.6W | 249.6W | |
Ripple and noise | <50mV | <120mV | <150mV | <240mV | |
Voltage accuracy | ±2% | ±1% | |||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | ||
Linear adjustment rate | <±0.5% | ||||
Input | Voltage range | 185-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
Efficiency (typical) | >82% | >84% | >84% | ||
Working current | <2.5A 220VAC | ||||
Impulse current | 220VAC 36A | ||||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Short circuit protection | +VODrop to undervoltage point to close output | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output 1.5KVAC <5mA | ||||
Leakage current | Input output 220VAC <1mA | ||||
Isolation resistance | Input output,Input - Housing, Output - Housing:500VDC/100MΩ | ||||
Other | Size | 199*50*110mm(L*W*H) | |||
Net Weight /Gross Weight | 0.72/0.78KG |
MS-350 350W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 29A | 14.5A | 9.7A | 7.3A | |
Rated power | 350W | 350W | 350W | 350W | |
Ripple and noise | <120mV | <240mV | <240mV | <240mV | |
Voltage accuracy | ±1.0% | ||||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | ±0.5% | ||||
Linear adjustment rate | ±0.5% | ||||
Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
Efficiency (typical) | >83% | >85% | >86% | >86% | |
Working current | 110VAC 25A, 220VAC: 50A | ||||
Impulse current | <5.5 A 115VAC <2.9A 230VAC | ||||
Start, rise, hold time | 200ms,50ms,20ms :230VAC | ||||
Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Short circuit protection | 115%-145% | ||||
Undervoltage protection | 10%-45%VOUT | ||||
Temperature protection | Rth3: ≥ 55 ºC fan start, ≥ 50 ºC fan close, ≥ 85 ºC close output (5v-15v) | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 2.5kvac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output 1.5KVAC <6mA | ||||
Leakage current | Input output 220VAC <1.5mA | ||||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||||
Other | Size | 199*38*98mm(L*W*H) | |||
Net Weight /Gross Weight | 0.62/0.65 KG |



1. who are we?
We are based in Zhejiang, China, start from 2015,sell to Domestic Market(30.00%),North America(20.00%),South Asia(6.00%),Mid East(6.00%),Eastern Asia(5.00%),Oceania(5.00%),Southern Europe(5.00%),Western Europe(4.00%),Northern Europe(4.00%),Africa(4.00%),South America(3.00%),Central America(3.00%),Southeast Asia(3.00%),Eastern Europe(2.00%). There are total about 51-100 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Switching power supply
4. why should you buy from us not from other suppliers?
Junlin switching power supply is widely used in industrial automation LED lighting and display, medical, security, power control, metallurgy, water treatment, infrastructure, and other fields.
5. what services can we provide?
Accepted Delivery Terms: null
Accepted Payment Currency:null;
Accepted Payment Type: null;
Language Spoken:null
We are based in Zhejiang, China, start from 2015,sell to Domestic Market(30.00%),North America(20.00%),South Asia(6.00%),Mid East(6.00%),Eastern Asia(5.00%),Oceania(5.00%),Southern Europe(5.00%),Western Europe(4.00%),Northern Europe(4.00%),Africa(4.00%),South America(3.00%),Central America(3.00%),Southeast Asia(3.00%),Eastern Europe(2.00%). There are total about 51-100 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Switching power supply
4. why should you buy from us not from other suppliers?
Junlin switching power supply is widely used in industrial automation LED lighting and display, medical, security, power control, metallurgy, water treatment, infrastructure, and other fields.
5. what services can we provide?
Accepted Delivery Terms: null
Accepted Payment Currency:null;
Accepted Payment Type: null;
Language Spoken:null