MS Series
Single
3 Years
15W/25W/35W/50W/75W/100W/150W/200W/350W
110-220V
Series Switching Power Supply
Separate-excited Switching Power Supply
Width Modulation Type
Terminal Power Distribution Equipment
One-way Transmission
PWM
CE, RoHS, ISO, CCC
Nvvv
Short Circuit Overload Overvolt Overtemp
1A-20A
Switch Power Supply
1PCS
86%~95%
100%Factory
5V 12V 24V 36V 48V
LED Display/Household Appliances/Industrial Device
47-63Hz
NVVV
Safety Packaging
199*110*50
China
Product Description






MS-15 15W Switching Power Supply | |||
Project | Technical index | ||
Output | DC voltage | 12V | 24V |
Rated current | 1.25A | 0.62A | |
Rated power | 15.6W | 16.8W | |
Ripple and noise | <120mV | <150mV | |
Voltage accuracy | ±1% | ||
Output voltage regulation range | ±10% | ||
Load adjustment rate | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | ||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |
Efficiency (typical) | >82% | >84% | |
Working current | <0.3A 110VAC <0.15A 220VAC | ||
Impulse current | 110VAC 18A, 220VAC 36A | ||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |
Short circuit protection | +VODrop to undervoltage point to close output | ||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |
Leakage current | Input output 1.5KVACtime <5mA | ||
Leakage current | Input output 220VACtime <1mA | ||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||
Other | Size | 87*37*60mm (L*W*H) | |
Net Weight /Gross Weight | 0.15/0.18 KG |
MS-25 25W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 5V | 12V | 24V |
Rated current | 4A | 2.1A | 1A | |
Rated power | 20W | 25.2W | 24W | |
Ripple and noise | <50mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >78% | >82% | >84% | |
Working current | <0.5A 110VAC <0.25A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVACtime <5mA | |||
Leakage current | Input output 220VACtime <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 87*37*60mm (L*W*H) | ||
Net Weight /Gross Weight | 0.15/0.18 KG |
MS-35 35W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 5V | 12V | 24V |
Rated current | 6A | 2.9A | 1.5A | |
Rated power | 30W | 34.8W | 36W | |
Ripple and noise | <50mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >78% | >82% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVACtime <5mA | |||
Leakage current | Input output 220VACtime <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 87*37*60mm (L*W*H) | ||
Net Weight /Gross Weight | 0.15/0.18 KG |
MS-50 50W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 5V | 12V | 24V |
Rated current | 8A | 4.2A | 2.1A | |
Rated power | 40W | 50.4W | 50.4W | |
Ripple and noise | <50mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >78% | >82% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-60 60W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 5A | 2.5A | 1.25A | |
Rated power | 60W | 60W | 60W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-75 75W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 6.25A | 3.12A | 1.56A | |
Rated power | 75W | 75W | 75W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Incput | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >84% | >84% | >84% | |
Working current | <1A 110VAC <0.65A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | vInput output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 111*36*78mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3/0.35KG |
MS-100 100W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 8.3A | 4.1A | 2.1A | |
Rated power | 99.6W | 100.8W | 100.8W | |
Ripple and noise | <120mV | <150mV | <240mV | |
Voltage accuracy | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <1.8A 110VAC <1.1A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 159*38*98mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3KG |
MS-120 120W Switching Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | 48V |
Rated current | 10A | 5A | 2.5A | |
Rated power | 120W | 120W | 120W | |
Ripple and noise | <120mV | <150mV | <150mV | |
Voltage accuracy | ±1% | |||
Output voltage regulation range | ±10% | |||
Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) | >82% | >84% | >84% | |
Working current | <2A 110VAC <1.3A 220VAC | |||
Impulse current | 110VAC 18A, 220VAC 36A | |||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
Short circuit protection | +VODrop to undervoltage point to close output | |||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
Leakage current | Input output 1.5KVAC <5mA | |||
Leakage current | Input output 220VAC <1mA | |||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
Other | Size | 159*38*98mm(L*W*H) | ||
Net Weight /Gross Weight | 0.3KG |
MS-250 250W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 40A | 20.8A | 10.4A | 5.2A | |
Rated power | 200W | 249.6W | 249.6W | 249.6W | |
Ripple and noise | <50mV | <120mV | <150mV | <240mV | |
Voltage accuracy | ±2% | ±1% | |||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | ||
Linear adjustment rate | <±0.5% | ||||
Input | Voltage range | 185-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
Efficiency (typical) | >82% | >84% | >84% | ||
Working current | <2.5A 220VAC | ||||
Impulse current | 220VAC 36A | ||||
Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||||
Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Short circuit protection | +VODrop to undervoltage point to close output | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output 1.5KVAC <5mA | ||||
Leakage current | Input output 220VAC <1mA | ||||
Isolation resistance | Input output,Input - Housing, Output - Housing:500VDC/100MΩ | ||||
Other | Size | 199*50*110mm(L*W*H) | |||
Net Weight /Gross Weight | 0.72/0.78KG |
MS-350 350W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 29A | 14.5A | 9.7A | 7.3A | |
Rated power | 350W | 350W | 350W | 350W | |
Ripple and noise | <120mV | <240mV | <240mV | <240mV | |
Voltage accuracy | ±1.0% | ||||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | ±0.5% | ||||
Linear adjustment rate | ±0.5% | ||||
Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
Efficiency (typical) | >83% | >85% | >86% | >86% | |
Working current | 110VAC 25A, 220VAC: 50A | ||||
Impulse current | <5.5 A 115VAC <2.9A 230VAC | ||||
Start, rise, hold time | 200ms,50ms,20ms :230VAC | ||||
Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Short circuit protection | 115%-145% | ||||
Undervoltage protection | 10%-45%VOUT | ||||
Temperature protection | Rth3: ≥ 55 ºC fan start, ≥ 50 ºC fan close, ≥ 85 ºC close output (5v-15v) | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 2.5kvac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output 1.5KVAC <6mA | ||||
Leakage current | Input output 220VAC <1.5mA | ||||
Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||||
Other | Size | 199*38*98mm(L*W*H) | |||
Net Weight /Gross Weight | 0.62/0.65 KG |





Q1:How many Voltage you can supply? A: 12v,24v,48v,50,60,110v(Depend on items).
Q2Can I have a sample order? A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.
Q3Do you have any MOQ limited for the order? A: Low MOQ, 1pc for sample checking is available. At the same time, we have overseas warehouses so that you can get the products faster.
Q4How do you ship the goods and how long does it take to arrive? A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5Do you offer guarantee for the products? A: Yes, we offer warranty to our products.
Q6: How to deal with the faulty? A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.