MK-MG1288
1 Year
1 Year
Orc Turbine Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Low Noise
AC Rotating Exciter
Markevina or OEM
Wooden Case
Customized
China
Product Description
ORC Turbine Generator,
Organic Rankine Cycle Generator for Industrial Use
4.2 Performance parameter table of waste heat generating set
Note: [1] The net generating power is the power after deducting the power consumption of organic working medium pump, cooling water circulation pump and heat transfer oil working medium pump.
4.3 Turbine performance parameter table
4.4 Generator performance parameter table:








Organic Rankine Cycle Generator for Industrial Use
4.1 Project heat source conditions
No | project | value | unit | Remark |
1 | Heat transfer oil flow | ~ 360 | m 3 /h | |
2 | Heat transfer oil supply temperature | ~ 220 | ºC | |
3 | Heat transfer oil return oil temperature | ~ 180 | ºC | |
4 | Heat transfer oil specific heat capacity | ~ 2.538 | kJ/kg·ºC | @ 200 °C |
5 | Heat transfer oil density | ~ 732.8 | kg g / m3 | @ 200 °C |
6 | Thermal oil heat release power | ~ 7,439 | kW |
No | project | value | unit | Remark |
1 | input thermal power | ~ 7,439 | kW | |
2 | Installed power | ~ 1,000 | kW | |
3 | Generating power | ~ 900 | kW | |
4 | power generation efficiency | ~ 12.15 | % | |
5 | Net generating power [1] | ~ 760 | w _ | |
6 | cold water inlet temperature | ~3 0 | ºC | |
7 | cold water temperature | ~40 | ºC | |
8 | cooling water flow | ~ 560 | t/h | |
9 | Condensing power | ~ 6 , 540 | kW | |
10 | Organic working fluid pump power consumption | ~9 7 | kW | |
1 1 | Cooling water circulation pump power consumption | ~ 33 | kW | |
1 2 | Heat transfer oil pump power consumption | ~ 10 | kW |
4.3 Turbine performance parameter table
No | project | value | unit | Remark |
1 | Installed power | ~ 1,000 | kW | |
2 | rated power | ~ 900 | kW | |
3 | Axial series | 4 | class | |
4 | working fluid maximum inlet pressure | 3 | M P a | Except for special models |
5 | Working fluid maximum entry temperature | 250 | ºC | Except for special models |
6 | Work substance | R 245 fa | ||
7 | isentropic efficiency | ≥ 82 | % | |
8 | Load adjustment range | ~ 3 0~1 1 0 | % | |
9 | noise level | ≤85 | dB(A) | (@1 meter) |
1 0 | Unit design life | ≥ 18 | Year | In addition to wearing parts |
No | project | value | unit | Remark |
1 | Installed power | ~ 1,000 | KW | |
2 | Rated output voltage | 400 | V | |
3 | rated frequency | 50 | Hz | |
4 | Phase | 3 | Mutually | |
5 | power factor | 0.8 | - | |
6 | Rated speed | 1,500 | rpm | |
7 | Insulation class | f | class | |
8 | installation method | B3 | - | |
9 | degree of protection | I P55 | - | Tentative |
1 0 | Explosion-proof grade | none | - |
- Turbine generator Quotation List
No | Device name | parameter | quantity | unit | Remarks |
1 | Turbine | ~ 1 , 0 00kW | 1 | set | Turbine + Generator |
2 | Lubricating oil skid station | - | 1 | set | |
3 | Generator | ~ 1 , 0 00kW | 1 | set | |
4 | Pry rack | 1 | set | ||
5 | Shipping fee to China port | - | 1 | set | |
6 | Fees for distance technical services | 1 | set |