Outdoor Pole-Mounted Auto-Link Sectionalizer Isolation Gw9 Medium High/Voltage Disconnect Disconnector

Price $140.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 329 people viewed
Quantity
+-
 

Denggao Electric Co., Ltd.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
GW9
High-voltage
Three-column Disconnector
Outdoor High-voltage
Electric
Grounding
Horizontal Rotary Type
Three Pole
Electric
50Hz
12kv
630(1250)a
20(25)/4ka/S
DGG
Export Box
China
853530900
Product Description
Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.

General

The GW9 outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power systems with a rated voltage of 12kV to make or break power supply under circumstances of voltage and no load. The isolator adopts an isolated hook rod to operate.


Service conditions

1. The altitude does not exceed 1000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa. (corresponding to 34m/s wind speed).
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation hasn't frequent violent vibration.
6. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction area; however, it shouldn't be any explosive matters and matters causing a fire.


 
Technical parameters
No.ItemUnitData
1Rated frequencyHz50
2Rated voltagekV12
3Rated currentA630(1250)
4Rated short-time withstand current and durationkA/s20(25)/4
5Rated peak withstand currentkA50(63)
6Rated short-time power frequency withstand voltageInterphase, to earth(dry)kV/min42/1
Interphase, to earth(wet)30/1
Break(dry)48/1
Break(wet)36/1
7Rated lightning impulse withstand voltageInterphase, to earthkV75
Break85
8Circuit resistanceμΩ≤80
9Mechanical lifeTimes3000
10Pollution grade e class
11Creepage distancemm≥372
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.

Test Reports
All products have undergone professional testing and certification.

Our Customer

Our customers are located all over the world.

Photos of Product
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA