Model | P4 UV/Vis Spectrophotometer | |
Optical System | Single Beam | |
Light Source | Tungsten Lamp, Deuterium Lamp | |
Detector | Silicon Photodiode | |
Bandwidth | 2nm | |
Wavelength | Range | 190 - 1100nm |
Accuracy | ±0.5nm | |
Repeatability | ≤0.2nm | |
Display | 0.1nm | |
Gyration speed | 10000nm/min | |
Scan speed | 4200nm/min | |
Photometric | Range | -0.301 - 3A,0 - 200%T,0 - 9999.9C |
Accuracy | ±0.003A @ 0.5A, ±0.006A @1A, ±0.5%T @ 0 - 100%T | |
Repeatability | ±0.0015A @ 0.5A, ±0.003A @1A, ±0.2%T @ 0 - 100%T | |
Noisy | ≤0.0005A @ 0A,≤0.001A @ 1A,≤0.002A @ 2A(500nm) | |
Stability | ≤0.002A/hr(500nm,2 hours after warming up) | |
Stray Light Port | ≤0.05%T | |
Baseline | ±0.002A | |
Memory | 236KB(Built-in), Unlimited (USB memory stick) | |
Display | 5 inches color screen(480x272) | |
Keypad | Resistive touch screen | |
Printer | Serial printer, USB printer (in line with HP PCL3 GUI printing language) Serial port (printing), USB-A (storage and printing), USB-B (online) | |
Port | Serial port (printing), USB-A (storage and printing), USB-B (online) | |
Holder | Standard | 10mm 4-cell holder |
Optional | 10 - 50mm 4-cell holder,10 - 100mm 4-cell holder,10mm 8-cell Automatic Holder,10 - 100mm 5-cell Automatic Holder, Micro Cell Holder, Peltier/Sipper System, Reflectance Accessories, Solid Sample Holder, Water-Jacked 1 or 4-cell holder, Test Tube Holder | |
Function | Photometric | Yes |
Quantitation | Yes | |
Spectrum | Yes | |
File Management | Yes | |
System Management | Yes | |
Performance Verification | Yes | |
Language | 6 languages (English, German, French, Spanish, Portuguese, simplified Chinese) | |
Power | 100 - 240V AC, 50/60Hz, 120W | |
Dimensions | 456(W)×360(D)×185(H)mm | |
Weight | 10.7kg |
Features
Color Screen
- Friendly interface
- Built-in Method
- Using the 1200 l / mm holographic grating with low stray light, the optimized optical path design ensures the high accuracy of the instrument;
- The new wavelength driving mechanism has greatly improved the wavelength accuracy and repeatability, and effectively reduced the noisy;
- All aluminum die casting base and all moulded shell, make the instrument more sturdy and durable;
- High resolution TFT color LCD touch screen provides excellent display effect and simple operation;
- Self-calibration system while switching on and preheating countdown;
- Support USB memory to upgrade firmware directly;
- It can connect computers through USB, control instrument by software and can enrich and expand applications by software;
- It also supports USB universal printer and serial micro printer based on PCL3 GUI protocol;
- Wide sample room, suitable for 5~100 mm sample holder and other accessories;
- Added Spectrum Scanning function, it's the first time in the same level instrument;
- Automatic move wavelength to set position, automatic zero correction;
- It can connect to the printer and output the measurement results directly.
Photometry Test
- A / T one key conversion;
- Results can be recorded, edited, deleted, saved and printed.
- Single and dual wavelength method (dual wavelength difference, dual wavelength ratio) to measure samples;
- 3 methods to establish standard curve (input equation coefficient, measure 2~10 standard samples or input standard sample absorbance and concentration);
- 3 kinds of fitting methods (linear zero, linear, two order);
- Standard curve can be saved and invoked;
- Built-in19 concentration units and custom input;
- The measurement results can be recorded, edited, deleted, saved, and printed.
- The scanning speed is optional (low, medium, high);
- The scanning interval is optional (0.1, 0.2, 0.5, 1, 2, 5, 10nm);
- A / T display mode can be switched;
- Automatically find the peak;
- Point by point (peak) view;
- Coordinate adaptable and modifiable;
- Curves and data can be deleted, saved and printed.
- Files can be deleted, renamed, batch import / export, converted to .txt and .csv format.
1. system calibration (dark current, wavelength, system baseline);
2. Light source management (light source switch, timing);
3. Clock management;
4. Memory management (storage status display, formatting);
5. Multi language (can be switched);
- Wavelength accuracy; Photometric precision;
- Hetero astigmatic light; Wavelength accuracy;
- Photometric precision; Hetero astigmatic light; Noise; Noise;
settings).
Performance Verification
- Wavelength Accuracy;
- Photometric Accuracy;
- Stray light;
- Noisy;
- Dark noisy;
- Stability;
- Spectral band width.
EasyUV 1.0 is an application software based on Windows operating system.
Software Function:
- Photometric measurement;
- Quantitative measurement;
- Kinetics measurement;
- Multi wavelength measurement;
- Spectrum scanning;
- DNA / protein measurement.
At the same time, the application range, data analysis and file management function of P series instruments are greatly expanded, so that your analysis and measurement work becomes more relaxed and efficient.
Characteristics
- Photometric measurement: one key switch A / T / E;
- Quantitative measurement: establish standard curve;
- Spectrum scanning: coordinate adaptive;
- File management: data preservation, editable file name;
- Performance verification: verifiable performance specifications;
- System application: Multilingual operating system;
Part No. | SN | Description | Qty |
P4 | 1 | Instrument | 1set |
2 | User's manual | 1pc | |
3 | Cuvette quartz, 10mm | 2pcs | |
4 | Cuvette glass,10mm | 4pcs | |
5 | Fuse (3.15A/250V) | 2pcs | |
6 | Power cable (national standard) | 1pc | |
7 | Dustcover | 1pc | |
MEAS: | 456 (W) x360 (D) x185 (H) mm | ||
N.W.: | 10.7KGS | ||
G.W.: | 13.7KGS |