PT-SD series
Pressure Steam
Steam Sterilizer
CE, ISO13485
380V
With LCD Display
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Stainless Steel
1500-4500kg
28-347 Kg/Cycel
260-2000 L/Cycel
230-400 L/Cycel
High Precision
380V
Computerized
New
Steam Sterilization Equipments
Standard/Customized
Field Installation, Commissioning and Training
Pharmec
Wooden
Standard/Customized
China
Product Description
Pharmaceutical Autoclave Ampoule Syrup and IV Solution Small Vial Bottle Steam Sterilizer
Introduction
PT-SD Series Steam Sterilizer is mainly used for the sterilization, leak test and washing of ampoule, syrup and IV solution with small capacity. It adopts pressure steam as sterilizing medium to achieve the uniform sterilization between 105ºC~127ºC. This sterilizer adopts heating mode of displacement and exhausting from multi-points to ensure the through elimination of cold air in chamber, uniform and rapid heating and eliminate the dead corner caused by the existing cold air. Leak test by vacuum and color water is adopted to improve the detection rate of waste after sterilization, meanwhile provides the documents system that meets 2010 version GMP requirement.
PT-SD Series Steam Sterilizer is mainly used for the sterilization, leak test and washing of ampoule, syrup and IV solution with small capacity. It adopts pressure steam as sterilizing medium to achieve the uniform sterilization between 105ºC~127ºC. This sterilizer adopts heating mode of displacement and exhausting from multi-points to ensure the through elimination of cold air in chamber, uniform and rapid heating and eliminate the dead corner caused by the existing cold air. Leak test by vacuum and color water is adopted to improve the detection rate of waste after sterilization, meanwhile provides the documents system that meets 2010 version GMP requirement.
Equipment Model | Door | Trolley | Chamber Dimension | Overall | Weight | Clean | Deionized | Clean | C A | Control | Driver | Color |
Volume | Dimension | (Unloading) | Steam | Water | Water | Power | Power | Water | ||||
(Option) | ||||||||||||
m3 | mm | Kg | Kg/cycel | L/cycel | L/cycel | Nm3/h | 220V/Kw | 380V/Kw | L/cycel | |||
PT-XG1. SDE-0.6 | 2 | 1 | 1200*610*910/0.67 | 1490*1390*1940 | 1500 | 28 | 260 | 230 | 5.8 | 0.5 | 2 | 500 |
PT-XG1. SDH-0.8 | 2 | 1 | 1450*610*910/0.80 | 1742*1390*1940 | 1600 | 34 | 310 | 280 | 7.7 | 0.5 | 2.9 | 650 |
PT-XG1. SDA-1.0 | 2 | 2 | 1700*610*910/0.94 | 1992*1390*1940 | 1800 | 48 | 350 | 280 | 9.6 | 0.5 | 2.9 | 850 |
PT-XG1. SDB-1.2 | 2 | 1 | 1500*680*1180/1.20 | 1812*1465*1940 | 2300 | 58 | 400 | 280 | 12 | 0.5 | 2.9 | 1000 |
PT-XG1. SDC-1.5 | 2 | 2 | 1870*680*1180/1.50 | 2182*1465*1940 | 2550 | 74 | 650 | 400 | 14.4 | 0.5 | 4.6 | 1250 |
PT-XG1. SDD-2.0 | 2 | 2 | 1700*1000*1200/2.04 | 2062*1792*1990 | 2650 | 107 | 700 | 400 | 19.2 | 0.5 | 4.6 | 1700 |
PT-XG1. SDG-2.5 | 2 | 2 | 2100*1000*1200/2.52 | 2462*1792*1990 | 2900 | 138 | 750 | 400 | 24 | 0.5 | 4.6 | 2100 |
PT-XG1. SDN-3.0 | 2 | 3 | 2500*1000*1200/3.00 | 2862*1792*1990 | 3250 | 159 | 800 | 400 | 28.8 | 0.5 | 6.05 | 2500 |
PT-XG1. SDO-3.5 | 2 | 3 | 2900*1000*1200/3.48 | 3262*1792*1990 | 3450 | 175 | 1060 | 400 | 33.6 | 0.5 | 6.05 | 3000 |
PT-XG1. SDF-5.0 | 2 | 4 | 4200*1000*1200/5.04 | 4562*1792*1990 | 4300 | 277 | 1850 | 350 | 48 | 0.5 | 6.2 | 4300 |
PT-XG1. SDQ-6.0 | 2 | 5 | 5200*1000*1200/6.24 | 5562*1792*1990 | 4500 | 347 | 2000 | 350 | 57.6 | 0.5 | 6.2 | 5500 |