Phase Sequence Tester Indicator 3 Phase Rotation Tester Digital Phase Indicator Detector LED Meter

Price $80.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 334 people viewed
Quantity
+-
 

EP HIPOT ELECTRIC CO., LTD.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
EPR60
Remote Guidance
1/2 Years Free Warranty and Lifetime Maintenance
Indicator
Direct Connected
Three-phase Four-wire
Electronic Meter
Continuous Wave
RoHS, ISO, CE
Non-Customized
Phase Detection (Positive Phase, Reverse Phase), L
9V Battery, Continuous Use Time Is About 70 Hours
Non-Contact Clamping Method
The Wire to Be Measured Is in The Center of The Ja
50Hz/60Hz Automatic Recognition
AC70~1000V, 45/65Hz (Sine Wave Continuous Input),
AC1000V
Outer Diameter Phi 1.5mm~48mm
The Power Indicator Light Is on After The Power Is
0.6m
Length 117.6mmwidth 81mmthickness 25mm
About 6 Minutes After Power on, The Meter Will Aut
When The Battery Voltage Drops to About 5.2V, The
Meter: 260g (Including Battery)
300mva
EP Hipot Electric
Carton
260g
China
903031100
Product Description
General Information:
The EPR60 three phase rotation indicator (also called: non-contact phase detector) is a major breakthrough in the traditional phase sequence detection method. In the traditional phase sequence detection, the terminal of the three-phase wire must be removed, and the three exposed clips or test pins of the phase sequence meter must be connected to the exposed 3 live wires, and EPR60 adopts clamp-shaped non-contact inductive measurement. There is no need to remove the wires or touch the high-voltage exposed live wires. Directly clamp the three ultra-inductive high-insulation clamps to the insulation skins of the three-phase live wires to detect phases. At the same time, sound and light indicate the positive or negative state of the phase sequence of the three-phase power supply.

The EPR60 three phase rotation indicator also has functions such as live line inspection, simple power inspection, open circuit search, break point location, line maintenance and so on.

The EPR60 three phase rotation indicator is quick and convenient to detect, and the display is clear at a glance, which greatly improves the safety of on-site testing, effectively protects the personal safety of operators, and increases productivity. It is the three-phase power supply phase sequence, motor detection, and circuit maintenance. Safety equipment.

Main technical data table:
ItemsTechnical Specifications
FunctionsPhase detection (positive phase, reverse phase), live line check, simple power check, lack of phase judgment, open circuit search, break point location, line maintenance.
Power Supply9V battery, continuous use time is about 70 hours.
Measurement MethodNon-contact clamping method
Wire PositionThe wire to be measured is in the center of the jaws
Frequency50Hz/60Hz automatic recognition
Live Power RangeAC70~1000V, 45/65Hz (sine wave continuous input), static electricity detection.
Measure The Highest VoltageAC1000V
Clamp Wire SizeOuter diameter ø1.5mm~ø48mm
Display[Normal phase] The 4 phase detection lights turn on sequentially in a clockwise direction;
[Reverse phase] The 4 phase detection lamps turn on in order in a counterclockwise direction.
[Live electricity] L1, L2, and L3 lights are on within the voltage setting range.
[Lack of phase] L1 or L2 or L3 light is off.
[Open circuit] L1 or L2 or L3 light is off.
Buzzer [Normal phase] The instrument emits intermittent short beeps;
[Reverse phase] The instrument emits a continuous long beep.
Battery CheckThe POWER indicator light is on after the power is turned on; the LOW BATTERY light is on when the battery is insufficient.
Clamp Lead Length0.6m
Instrument SizeLength 117.6mm×Width 81mm×Thickness 25mm
Automatic Shut-DownAbout 6 minutes after power on, the meter will automatically shut down to reduce battery consumption
Battery VoltageWhen the battery voltage drops to about 5.2V, the battery voltage low symbol is displayed, reminding to replace the battery
WeightMeter: 260g (including battery)
Maximum Rated Power300mVA
Working Temperature and Humidity-10ºC ~ 55ºC, below 80%rh
Storage Temperature and Humidity-20ºC ~ 60ºC, below 90%rh
Dielectric Strength3.7kVrms
Suitable For Safety RegulationsEN61010-1: 2001, EN61010-031: 2002, pollution level 2,
CAT III (600V), instant overvoltage 6000V.