HPM47W-C
Level sensor
SemiConductor Type
Ceramic Pressure Transmitter
Analog Type
Integration
Metal, PTFE, PVDF, PVC PP
NA
Two-Wire
Liquid
IP68
ISO9001
Customized
Ceramic capacitor Pressure Sensor
0~0.5...200mH2O
2 times the full scale
0.2%F.S.
0.1%FS/year
24VDC
4-20mADC, 0~5VDC or Modbus RTU/RS485
Optinal
-10~70ºC
IP68
Plastic(PP,PVC, PTFE, PVDF) or metal(316L, TI)
PTFE, PU
Plastic probe: -10~70ºC, metal probe:-20~80&o
HIGHJOIN
Carton
China
90262010
Product Description
HPM47W (with ceramic capacitive sensor) anti corrosion pressure transmitter is a fully sealed submersible structure and uses an anti corrosion ceramic capacitive pressure sensor. The probe put into the measured medium is made of 316L, titanium alloy or
corrosion resistant materials such as PVDF, PP, PTFE or PVC, and the gas conductive cable is made of with PTFE or polyurethane jacket . It is mainly used for liquid level measurement of corrosive media such as acids and alkalis or s ewage, seawater and other media and all high demand liquid level measurement.

Product Features
 
  • High purity ceramic (99.9% Al2O3 ) capacitive sensor
  • Fluorine rubber ring waterproof seal for plastic probe Full welding process for
    metal probe.
  • Corrosion resistant design of probe and cable
  • Large measuring range, from 0.5 meters to 4 00 meters h igher range can be
    customized.
  • Full potting process, containing polymer sieve to prevent condensation
  • Multiple protection and sealing structure design
  • Plastic probe has built in counterweight
Product Parameters
Measuring Range
Rated range
(Gauge pressure,kPa*)
102040100200400100020004000**
Min Range
(Gauge pressure,kPa)
510205010020050010002000
Overload(kPa)400600600100018002500400040006000
*The measurement unit can be converted to mH2O@4ºC, inH2O@4ºC, m, mm, etc.
When using m, mm, etc. as the unit, please give the density value of the measurement medium.
**Range only available for metal probe
Measuring MediumVarious liquids compatible with contact materials
Output Signal/Power Supply (1)4~20mADC / Vs=10~30 VDC
Output Signal/Power Supply (2)4~20mADC+HART / Vs=12~32 VDC
Output Signal/Power Supply (3)0~5V etc. /Vs=10~30 VDC
Output Signal/Power Supply (4)Modbus-RTU/RS485 /Vs =3~8 VDC or 10~30 VDC
Accuracy
*Accuracy complies with IEC 60770 (non-linearity, hysteresis, repeatability)
±0.25%FS(typical); ±0.1%FS(with HART)
Load characteristics4~20mADC 2-wire: RL≤(U-10)/0.02Ω
4~20mADC+HART 2-wire: RL≤(U-12)/0.02Ω
Voltage output, 3-wire: RL>10kΩ
Long-term Stability±0.2%FS/year
Response timeAbout 1ms
Startup time≤3s
Compensation temperature range-20~80ºC
Temperature Coefficient of Zero±1.0%FS (in compensation temperature range)
Temperature Coefficient of Full Scale±0.8%FS (in compensation temperature range)
Operation Temperature   Plastic Probe: -10~70ºC
Note: The operating temperature of PVC material products is 0~60ºC; the operating temperature of PP material products is 0~70ºC
Metal probe: -20~80ºC
Medium TemperaturePlastic Probe: -10~70ºC; Metal probe: -20~80ºC
Storage TemperaturePlastic Probe: -10~70ºC; Metal probe: -20~80ºC
Protection GradeIP68(for probe)
Short circuit protection With
Structure Materials
 
Ordering CodePartNote
DFProbe Shell materialPVDF,Density 1.78g/cm3,Shore hardness 77,
applicable temperature -10~140ºC
PCPVC,Density 1.45g/cm3,Shore hardness 79,
applicable temperature 0~60ºC
PPPP, Density 0.91g/cm3,Shore hardness 72,
applicable temperature 0~100ºC
FEPTFE,Density 2.17g/cm3,Shore hardness 54~60,
applicable temperature -200~260ºC
S6316L
TItitanium alloy
M5Pressure sensorCeramic Al2O3 99.9%
FKSealing ringFKM(applicable temperature -20~200ºC)
FFFFKM(More corrosion resistant,applicable temperature -25~300ºC)
C2FCablePTFE,outer diameter(7.2±0.2)mm
C2UPU,outer diameter(7.2±0.2)mm
Weight (Unit:g)
Probe  
MaterialPVCPPPVDFPTFE316LTI
Weight
 (Cable not included)
~500~450~550~600~660~400
Cable
MaterialPTFEPU
Weight(1m)~60~50
Dimension (Unit:mm)
 
Plastic ProbeMetal Probe

* The size is the distance between the induction diaphragm and the bottom


 
Installation

Accessories(Unit:mm)
Thread installation (W1) dimension

weight:~400g
1.Used for fixing and supporting the whole product on the top
2. Besides G1 thread, other threads can be customized if needed
 

 
Ordering Guide