Point Type Dual Band Infrared Flame Detector for Alarm System Jtgb-UF-Yjlh101ex

Price Negotiable Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 262 people viewed
Quantity
+-
 

Shenzhen Xinhean Technology Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
JTGB-UF-YJLH101EX
2 Band Infrared Flame Detector
Wired Alarm
Alarm Flame Detector
CCC
Indoor, Outdoor, Fire Detection
Infrared Flame Detection
Wired
≥80dB
DC24V
Less Than 10s
Relay Output
Level 1(25m)
XHA
Carton
10pcs/Carton
China
8531100000
Product Description

JTGB-UF-YJLH101EX Point Type Dual Band Infrared Flame Detector For Alarm System



Introduction


Infrared (IR) flame detectors are specialized sensors designed to detect the presence of flames by identifying the unique infrared light signature produced by combustion. These devices are widely used in industrial and commercial applications to provide early warning of potential fire hazards.

It's suitable for the industries of petroleum, petrochemical refineries, pipelines, chemical plant, coking plant, oil depot and gas station, CNG, LNG, wine library, spray paint room, drilling platform, city gas, boiler room, metallurgical industry, fire engineering, ships, electric power industry and so on easy to produce liquid or gas fire, smokeless fire and explosion.



Specifications

 

 

 

Working voltage18V-32VDC
Interface4"(Φ20mm) explosion-proof hose
Infrared Flame Detector Detection Angle90 degree
Level of protectionIP66/IP65
Explosion Proof LevelEx d lIC T6 Gb. Ex tD A21 IP66/IP67 T80ºC
Alarm Status≤40mA/24VDC
Fire response time≤10S
Sensitivity1m-40m can respond(0.1 m-1.3m)
Working environmenthumidity ≤95%RH, no condensation


 

Instruction

 


The green work indicator is steady on at the normal situation.
when the fire is found, The red alarm indicator is steady on. At the same time, the fire alarm relay is closed and the yellow/white lines are conductive, output the fire alarm signal.
The detector is a non-coding detector, which needs to connect the interface module when it is connected to the bus system.

 

Wiring Instruction

 


Red/black: 24V power line
Yellow/white:Alarm relay ouput, it is closed, normally open.
Blue/green:Fault relay output, it's open, normally closed.
Maintenance:
In order to keep in good work situation, it need arrange test to the flame detector every 3 months at least. Once the detector is damaged or not working properly, need to repaire or replace accordingly.

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 10 working days lead time.

5. Welcome sample order.

Conpany Profile
Customized Gas Extinguishing Control PanelCustomized Gas Extinguishing Control Panel


Assembly Line
Customized Gas Extinguishing Control Panel

Burn-in Room
Customized Gas Extinguishing Control Panel

Quality Management System
Customized Gas Extinguishing Control Panel



 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA