Portable 350cfm 8bar Mining Diesel Engine Mobile Screw Air Compressor for Sandblasting

Price $18000.00 Compare
Min Order 1 Set
Shipping From Hebei, China
Popularity 314 people viewed
Quantity
+-
 

Muqi Air Compressor Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
MQ350
24/7 After Sale Service
18 Months
Lubricated
Air Cooling
Diesel Engine
Vertical
Closed Type
Movable Type
Twin-Screw Compressor
Screw Compressor
1*3/4" 1*1-1/2"
300sets/Month
Mining
8 Bar -16bar
Support Custom Machine
MUQ
Standard Export Packing
3840*1490*1780
China
8414200000
Product Description

Product Parameters
ModelDischarge Air Volume(m³/min)Discharge Pressure
(MPa)
Gas Oil ContentDischarge TemperatureDimension
L*W*H(mm)
Weight
(KG)
MQ18550.7≤5PPM≤110ºC3840*1490*17801270
MQ250E  70.83170*1600*16501650
MQ350E100.83170*1600*16502000
MQ350G101.33700*1960*20002200
MQ420E120.83700*1960*20002610
MQ460G131.33700*1960*20002800
MQ560GII161.33900*1900*21003000



 Operation Instructions:
A:Before Operation:
  1. Confirm the voltage of the power supply and the power indicator light is lit.
  2. Please open the leak valve of the oil & gas tank, drain the condensed water and immediately close the leak valve when oil leaks out.
  3. Please check the oil level and keep it between indicator oil level.
  4. Water cooled system , confirm that cooling water supply is normal.
  5. When generator driving the belt, please check the belt tension correctly, not too loose or too tight.
B:Start up
  1. Main power switch in.
  2.  Press the start button to turn on the motor, working indicator light is on.
  3. Check the discharge pressure gauge and lubricating oil pressure gauge are in correct indication.
C:Operation
  Please keep the exhaust temperature between 75ºC-95ºC to avoid condensation and precipitation and emulsify the oil.
D:Stop
  1. Press the "off" button, about 10-15 seconds later, the delay electromagnetic valve acts, and the compressor stops running.
  2. Turn off the power.
  3. Don't use the emergency stop button in case of non emergency.
E: Precautions:
  1. For initial start-up and after motor maintenance, determine the running direction of the press (as indicated by the arrow).
  2. Do not mix different brand of river lubricating oil.
  3. Change the consumables, lubricating oil and detail operation method, please refer the instruction manual.