FTIR-200P
12 Months
Yuan Zheng
Customized
Portable
CE
So2, Nox (No, No2), CH4, Nh3, HCl, Hf, Co, CO2, O2
Infrared Absorption Analyzer
YUAN ZHENG
Carbon Box
20 Kg
China
Product Description
Portable FTIR Gas Analyzer FTIR-200P
Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2, NOx(NO, NO2),CH4, NH3, HCl, HF, CO, CO2, O2, H2O. According to actual measuring need, it can be extended to measure other components, like SO3, N2O and etc. This portable system mainly comprises FTIR analyzer and sampling probe. It has features of high measurement accuracy, wide dynamic range and low detection limit.
Feature
Application
* Emission detection of fixed sources,
* CEMS comparison and acceptance,
* Emergency monitoring,
* laboratory measurement analysis
Specification






Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2, NOx(NO, NO2),CH4, NH3, HCl, HF, CO, CO2, O2, H2O. According to actual measuring need, it can be extended to measure other components, like SO3, N2O and etc. This portable system mainly comprises FTIR analyzer and sampling probe. It has features of high measurement accuracy, wide dynamic range and low detection limit.
Feature
- Warming up is no required for the analyzer to realize fast measurement;
- Applicable for high humidity and dust occasion
- Optical length up to 13m, extremely low detection limit, high range dynamics, satisfy the monitoring of small emission limit;
- By applying OLS and PLS techniques and selecting, interference from H2O or others can be effectively eliminated;
- Quick site sampling, analysis and easy operation.
Application
* Emission detection of fixed sources,
* CEMS comparison and acceptance,
* Emergency monitoring,
* laboratory measurement analysis
Specification
principle: | fourier transform infrared spectroscopy (FTIR) |
Range: | SO2: (0~75) mg/m3 |
NO: (0~200) mg/m3 | |
NO2: (0~40) mg/m3 | |
NOx: (0~200) mg/m3 | |
CO: (0~75) mg/m3 | |
H2O: (0~40) % | |
CH4: (0~20) mg/m3 | |
NH3: (0~10) mg/m3 | |
HCl: (0~15) mg/m3 | |
HF: (0~10) mg/m3 | |
CO2: (0~20) mg/m3 | |
Pretreatment Method: | condensation dewatering/whole process high temperature (optional) |
Repeatability: | ≤2% |
Zero Drift: | ≤±2%F.S./24h |
Span Drift: | ≤±2%F.S./24h |
Sampling Flow: | (1.5±0.5) L/min |
Response Time: | ≤90s (T90) |
Enclosure Protection: | IP41 |
Working Temp.: | 0~45ºC |
Working Pressure: | 80kPa~106kPa |
Humidity: | 0~95%RH |
Communication: | RS232&USB |