TD3250 Portable Three-Phase Energy Meter Tester

1. Summary
TD3250 is a portable standard meter specially used for electric energy meter on-site detection, AC sampling etc. It integrates the functions of electrical parameter measurement, electric energy meter calibration, connection mode identification, harmonic analysis, waveform display, phasor diagram display, data management.2. Features
- Accuracy: Class 0.02 or 0.05.
- 3PH voltage measurement: 0~480 V.
- 3PH current measurement (direct) : 50 mA~ 12 A.
- 3PH current measurement (clamp) : 100 mA~ 120 A.
- Support electric energy pulse optical/electrical pulse input.
- LCD touch screen.
- Support AC 100 V~264 V wide range supply.
- Support large capacity lithium battery.
- Internal memory, and quickly record test data.
- USB and RS232 interfaces.
3. Application

☆ Calibration for Energy Meter Online |
![]()
|
☆ CT Transformation Ratio Calibration |
![]()
|
4. Characteristics
☆ Convenient Operation |
![]()
|
![]()
|
☆ Connection Mode Identify and Graphical Display | |
![]() | |
S/N | Function declaration |
1 | Accurately measure/display the amplitude and phase of voltage and current of each phase. |
2 | Accurately measure the phase between voltage and current of each phase, and visually display them in the form of phasor diagram. |
3 | Automatically identify the actual results of voltage and current, including phase sequence display. |
4 | The trend chart display function of the measuring channel can display the trend change of the measured electricity quantity with time. |
5 | Users can customize single or multiple power waveforms for display. |
☆ Harmonic Function | |
![]() | |
S/N | Function |
1 | It can measure 2nd ~63rd harmonics and display the amplitude or content. |
2 | Display the phase value of each harmonic. |
3 | Display the waveform after harmonic superposition. |
4 | Display the phase of each harmonic. The spectrum of each harmonic is displayed visually in the form of histogram (fundamental wave is 100%). |
☆ Data Management |
![]() |
|
☆ Test Software |
![]() |
|
5. Specifications
5.1Three phase voltage/current measurement
Type | Measurement Mode | Range | Resolution | Accuracy ±(ppm of reading + ppm of range) [1] | |
Class 0.05 | Class 0.02 | ||||
ACV | Direct Measurement | 110 V | 1 mV | 300 + 200 | 120 + 80 |
220 V | 1 mV | 300 + 200 | 120 + 80 | ||
440 V | 1 mV | 300 + 200 | 120 + 80 | ||
ACI | Direct Measurement | 1 A | 10 μA | 300 + 200 | 120 + 80 |
10 A | 100 μA | 300 + 200 | 120 + 80 | ||
Clamp Measurement | 1 A[2] | 10 μA | 0.2%*RG | 0.1%*RG | |
5 A | 10 μA | 0.2%*RG | 0.1%*RG | ||
10 A[2] | 100 μA | 0.2%*RG | 0.1%*RG | ||
20 A[2] | 100 μA | 0.2%*RG | 0.1%*RG | ||
100 A[2] | 1 mA | < 50 A: 0.2%*RG; ≥ 50 A: 0.5%*RG | < 50 A: 0.1%*RG; ≥ 50 A: 0.2%*RG | ||
Note [1]: (ppm = parts per million) (e.g., 10ppm = 0.001%). Note [2]: The clamp of 5A model is standard, and other models is option. |
- Voltage input: 10 V~480 V, 6-digits decimal display.
- Current input (direct measurement): 0.05 A~12 A, 6-digits display.
- Current input (clamp measurement): 0.1 A~6 A, 6-digits display.
5.2 Frequency/Phase
Frequency | Range | 45.000 Hz~65.000 Hz |
Resolution | 0.001 Hz | |
Accuracy | ± 0.01 Hz | |
Phase | Range | 0.000°~359.999° |
Resolution | 0.001° | |
Accuracy | Direct Measurement: ± 0.05° | |
Clamp Measurement: ± 0.2° |
5.3 Three Phase Power / Energy Measurement
Power/Energy Parameters | Accuracy | |||
Direct Measurement | Clamp Measurement | |||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | |
Active P/E | cos φ| ≥0.5 | ± 0.05%*FS[3] | ± 0.02%*FS[3] | ± 0.2%*FS[3] | ± 0.1%*FS[3] |
Reactive P/E | sin φ| ≥0.5 | ± 0.1%*FS[3] | ± 0.05%*FS[3] | ± 0.5%*FS[3] | ± 0.2%*FS[3] |
Apparent power | ± 0.1%*FS[3] | ± 0.05%*FS[3] | ± 0.5%*FS[3] | ± 0.2%*FS[3] |
Power factor | ± 0.0005 | ± 0.0005 | ± 0.002 | ± 0.002 |
Note [3]: FS=voltage range value × current range value. |
- Power factor measurement range: -1.000 0... 0.000 0... 1.000 0.
- Standard electric energy pulse output: high frequency full range value corresponds to 60 kHz, low frequency full range value corresponds to 6 Hz.
- Standard electric energy pulse input: frequency ≤ 200 kHz, voltage: 0... 3.3 V... 24 V.
6. General Specifications
Power Supply | AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz |
Temperature Performance | Working temperature: 0°C~45°C Storage temperature: -20°C~70°C |
Humidity Performance | Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R·H, non-condensing |
Interface | USB, LAN |