CS100E
Free
3 Years
Wuhan Corrtest Instruments
450 G
Built-in Li-Battery 6000mAh@3.7V / USB
+/- 45mA
+/- 10V
Yes
10Hz ~ 1MHz
2na~50mA, 10 Ranges
Eis, I-T Curve, Tafel, CV, Lsv, Dpv, Npv, Swv
+/- 12V
Corrtest
Standard Carton
15 x 9 x 3cm
China
9027899090
Product Description

The CS100E handheld potentiostat supports full electrochemical methods, including potentiostatic/galvanostatic polarization curve, Cyclic voltammetry analysis, impedance(EIS), and galvanic current measurement. etc. It has built-in chargeable li-ion battery and Bluetooth communication. The device supports laptop/computer software or mobile APP. It can be used for electrochemical tests in field or special non-electricity environment. CS100E can be a convenient handheld tool for researchers of energy& materials, environment protection, biosensor, foods &drugs, corrosion protection etc. Maximum current is ±45mA
The voltage control range is ±10V, compliance voltage is ±12V, the maximum current output is ±45mA, and the minimum current resolution can reach 100fA. The EIS frequency range is 10μHz~1MHz.
Features
- Small & light, handheld and convenient
- Easy to install and use
- High accuracy, current resolution can reach to 100fA, and measurement accuracy is 0.1% of the range.
-during outdoor test, a laptop's USB port can be used for both charging and communicating
- The circuit adopts floating design. Electrochemical parameters of the grounded system can be measured without an isolation transformer.
Thanks to its small size with comprehensive electrochemical functions, it's typically used for:
- Battery materials' performance test in a glove box
- Ultra-low detection limit of heavy metal ions for water quality test in environmental protection field
- Low current detection in biosensor thanks to high current accuracy
- Effective ingredients detection in food and drug industry
- Outdoor bridge corrosion and soil corrosion measurements
Note: maximum current during experiment doesn't exceed ±45mA then the handheld potentiostat can be used. If exceeds ±45mA an ordinary size potentiostat with maximum current ±2A should be considered.
The CS100E portable can be controlled by either our desktop software or App.

Specifications
Size / weight:15 x 9 x 3 (cm), 450gPotential control range: ±10V
Maximum current: ± 45mA
Compliance voltage: ±12V
EIS frequency range: 10μHz ~ 1MHz
Potential range: ±2.5V, ±5V, ±10V
Current range: 200pA~50mA, 9 ranges
Potential accuracy: 0.1%× full range
Minimum potential resolution: 10mV
Current accuracy: 0.1%× full range
Minimum current resolution: 100fA
Reference electrode input impedance: 1013Ω||8pF
AC amplitude: 0~±2.5V
Signal response bandwidth: 1MHz
Max. acquisition rate: 150,000 data points/s
CV and LSV scan rate: 0.001mV~ 10V/s
Support 2-, 3-or 4-electrode system
Communication: USB / Bluetooth
Power supply: USB / built-in li-ion battery 6000mAH@3.7V
Electrochemical techniques
Stable polarization
- Open Circuit Potential (OCP)
- Potentiostatic (I-T curve)
- Galvanostatic
- Potentiodynamic (Tafel plot)
- Galvanodynamic (DGP)
- Multi Potential Steps
- Multi Current Steps
- Potential Stair-Step (VSTEP)
- Galvanic Stair-Step (ISTEP)
- Chronopotentiometry (CP)
- Chronoamperametry (CA)
- Chronocaulometry (CC)
- Linear Sweep Voltammetry (LSV)
- Cylic Voltammetry (CV)
- Staircase Voltammetry (SCV) #
- Square Wave Voltammetry (SWV) #
- Differential Pulse Voltammetry (DPV) #
- Normal Pulse Voltammetry (NPV)#
- Differential Normal Pulse Voltammetry (DNPV) #
- AC Voltammetry (ACV)
- 2nd harmonic AC Voltammetry (SHACV)
- Fourier Transform AC Voltammetry (FTACV)
Electrochemical Impedance Spectroscopy (EIS)
- Potentiostatic EIS (Nyquist, Bode)
- Galvanostatic EIS
- Potentiostatic EIS (Optional freq.)
- Galvanostatic EIS(Optional freq.)
- Mott-Schottky
- Potentiostatic EIS vs. Time (Single freq.)
- Galvanostatic EIS vs. Time (Single freq.)
- Potentiodynamic (Tafel plot)
- Cyclic polarization curve (CPP)
- Linear polarization curve (LPR)
- Electrochemical Potentiokinetic Reactivation (EPR)
- Electrochemical Noise (EN)
- Zero resistance Ammeter (ZRA)
- Battery Charge and Discharge
- Galvanostatic Charge and Discharge (GCD)
- Potentiostatic Charging and Discharging(PCD)
- Potentiostatic Intermittent Titration Technique(PITT)
- Galvanostatic Intermittent Titration Technique(GITT)