Potentiostat Galvanostat /Electrochemical Workstation with Eis Model CS350M

Price $6800.00 Compare
Min Order 1 Set
Shipping From Hubei, China
Popularity 218 people viewed
Quantity
+-
 

Wuhan Corrtest Instruments Corp., Ltd.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
CS350M
Free
3 Years
Non-Customized
Desktop
CE, ISO
School, Lab
Measurement Type
±10V
±2A
10μHz~1MHz
Support 2-, 3-, 4-, 5 Electrode System
Tafel, CV, Lsv, Eis, Ca, Gcd, Ocp, I-V
Corrtest
Standard Carton
benchtop, 36.5 x 30.5 x16cm
China
9027899090
Product Description
Model CS350M single-channel potentiostat/galvanostat with EIS consists of a DDS arbitrary function generator, a potentiostat/galvanostat and an FRA. With the help of built-in dual 24-bit Delta-sigma AD converters, it achieves excellent stability and high potential (1mV) and current(1pA) resolutions. CS350M has been widely applied in corrosion, energy, material and analysis electrochemistry. In addition, via current booster. CS350M can increase its output current up to 20A/40A/100A.

Application 
-Energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors, etc);
-Reactive mechanisms of electrosynthesis, electrodeposition (electroplating), anodic oxidation, electrolysis;
-Metallic corrosion; corrosion inhibitor, coating and cathodic protection efficiency;
-Electrocatalysis (HER, OER, ORR, CO2RR, NRR).

 
Specifications
Support 2-, 3- or 4-electrode systemPotential and current range: Automatic
Potential control range: ±10VCurrent control range: ±2A
Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz)Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Maximum current output: 2ACV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHzLow-pass filters: covering 8-decade
Operating System: Windows 10/11 Interface: USB 2.0
Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
EIS (Electrochemical Impedance Spectroscopy)
Signal generator
Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
DC Bias: -10~+10VOutput impedance: 50Ω
Waveform: sine wave, triangular wave and square waveWave distortion: <1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time:minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
Measurement delay: 0~105s
DC offset compensation
Potential automatic compensation range:-10V~+10VCurrent compensation range:-1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

 Model CS350M is the most comprehensive model, includes all electrochemical methods incl. EIS
 You can find the comparison of the single-channel models from the following table.
TechniquesCS300M
(No EIS)
CS310M
(with EIS)
CS350M
(with EIS)
Stable
polarization
Open Circuit Potential (OCP)
Potentiostatic (I-T curve)
Galvanostatic
Potentiodynamic(Tafel plot)
Galvanodynamic
Transient polarizationMulti-Potential Steps
Multi-Current Steps
Potential Stair-Step (VSTEP)
Galvanic Stair-Step (ISTEP)
Chrono
methods
Chronopotentiometry (CP)
Chronoamperometry (CA)
Chronocoulometry (CC)
VoltammetryCyclic Voltammetry (CV)
Linear Sweep Voltammetry (LSV)(I-V)
Staircase Voltammetry (SCV) # 
Square wave voltammetry (SWV) # 
Differential Pulse Voltammetry (DPV)#  
Normal Pulse Voltammetry (NPV)#  
Differential Normal Pulse Voltammetry (DNPV)#  
AC voltammetry (ACV) # 
2nd Harmonic A.C.Voltammetry (SHACV) 
AmperometryDifferential Pulse Amperometry (DPA)  
Double Differential Pulse Amperometry (DDPA)  
Triple Pulse Amperometry (TPA)  
Integrated Pulse Amperometric Detection (IPAD)  
EISPotentiostatic EIS (Nyquist, Bode) 
Galvanostatic EIS 
Potentiostatic EIS (Optional freq.) 
Galvanostatic EIS(Optional freq.) 
Mott-Schottky 
Potentiostatic EIS vs. Time (Single freq.) 
Galvanostatic EIS vs. Time (Single freq.) 
Corrosion
 test
Cyclic polarization curve (CPP)
Linear polarization curve (LPR)
Electrochemical Potentiokinetic Reactivation (EPR)
Electrochemical Noise(EN)
Zero resistance Ammeter (ZRA)
Battery testBattery charge and discharge
Galvanostatic charge and discharge(GCD)
Potentiostatic Charging and Discharging(PCD)
Potentiostatic Intermittent Titration Technique(PITT)
Galvanostatic Intermittent Titration Technique(GITT)
ExtensionsData Logger
Bulk electrolysis with Coulometry (BE)

Applications
Corrosion Electrochemistry

CS potentiostats/galvanostats support a variety of electrochemical techniques for corrosion, such as OCP recorder, potentiodynamic, EIS, cyclic polarization (CPP), LPR, hydrogen diffusion test, zero resistance ammeter (ZRA), electrochemical noise (ECN), etc.
Due to their high input impedance(1013Ω), they are especially suitable for EIS measurement of high-impedance systems like coating, concrete, and pure water.
High-impedance coating ageing test in salt spray tests
Polarization curves of Ti-alloy& stainless steel in 3%NaCl solution
ECN of low-carbon steel in 0.05mol/L Cl+0.1mol/L NaHCO3
Energy & Battery Testing
With versatile functions like linear sweep voltammetry (LSV), cyclic voltammetry (CV), galvanostatic charge/discharge (GCD), EIS (including potentiostatic and galvanostatic modes) with precise IR compensation, CS potentiostats are widely used in supercapacitor, Li-ion batteries, Li-S batteries, fuel cell, solar cell, solid-state batteries, flow batteries, and metal-air batteries, etc.
CV of PPy supercapacitor in 0.5 mol/L H2SO4 solution
Electrocatalysis
Based on CV and LSV techniques, CS potentiostats can carry out long-term tests for ORR, OER, HER, and CO2 reduction, which is crucial for evaluating catalyst stability. In addition, the CS2350M bi-potentiostat and multichannel potentiostat specialize in Faradaic efficiency synchronous measurement.
CS potentiostats can measure the half-wave potential (ORR) and overpotential (HER, OER) of catalysts and calculate the power density and energy density of Redox peaks.
LSV curves of various catalysts in alkaline solution
Analytical Electrochemistry
CS potentiostats include comprehensive voltammetric methods such as NPV, DPV, DNPV, SWV, and ACV, which make them ideal for quantitative analysis of trace elements via the intrinsic Voltammetry stripping techniques.
Stripping voltammetric curves in the solution dissolved with Pb2+, Cd2+, and Zn2+ ions

Electrochemical Sensor
Thanks to the high current sensitivity(100fA) and voltage resolution(1 mV), the CS potentiostat can be used for the R&D of biosensors and electrochemical sensors.

 
Technical Advantages
Switchable floating and earthing mode
All CS potentiostats/galvanostats can switch between the floating and earthing modes, and this strategy is beneficial for studying electrochemical systems in which the working electrodes are intrinsically ground, such as autoclaves, in-site concrete structures and multi-working electrodes requiring isolation, etc.

High-bandwidth EIS
With the help of built-in digital FRA and arbitrary signal generator, as well as the high input impedance (1013 W), the CS potentiostat is particularly suitable for EIS measurements of high-impedance systems (such as coating, membrane, concrete, etc.)
Based on the DC bias compensation technique, CS potentiostats can conduct EIS tests under different charge/discharge states of batteries, making them suitable for ultra-low resistance systems, such as power batteries, fuel cells, water-splitting equipment, etc.

Multiple electrode configurations
CS potentiostats support 2-, 3-, or 4-electrode configurations and can measure the galvanic current via built-in zero resistance ammeter circuits.

User-defined sequence test
CS Studio 6.0 for Windows software supports user-defined sequence tests ("combination test"), which can facilitate automatic testing according to user-defined experiment sequences.
Sequence Test: corrosion tests 
Power booster
Through CS2020B/CS2040B/CS2100B booster, the CS potentiostats can extend their output current up to ±20A/40A/100A, meeting the growing requirements in fuel cells, power batteries, electroplating etc.
The compliance voltage of single-channel potentiostat can be customized(±30V),suitable for carbon/nitrogen electrochemical reduction.
CS potentiostats can work with a CST520 arrayed electrode mapper to study the non-uniform corrosion of metal samples under deposits, coatings and anti-rust oils.

Software development kit (SDK)
All CS potentiostats run under the control of CS Studio 6.0 for Windows (CSS 6.0). The CSS6.0 supports third-party languages, such as LabVIEW, C, C++, C#, VC, Python and others. Some API general interfaces and development examples can be supplied with the CS potentiostats. Through the SDK, customers can implement user-defined test methods.
 
Real-time data Storage
CSS 6.0 saves experimental data timely, even if the experiment is accidentally interrupted by a power failure or computer shutdown. CSS 6.0 supports several data formats compatible with Originpro and Microsoft Excel.

Versatile data analysis functions
CSS 6.0 provides robust functions, including various electrochemical measurements and data analysis. It can complete Tafel plot fitting, CV derivation, integration and peak height analysis, EIS equivalent circuit fitting, etc.
3, 4 parameter polarization curve fitting.
EIS fitting
Electrochemical noise spectrum analysis
Pseudo-capacitance calculation
GCD-specific capacitance, efficiency calculation
Mott-Schottky analysis
CV curve analysis
Activation/re-passivation curve analysis


 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA