LW series
Active Inverter
ISO9001, CE
>1000W
off-Grid Inverter
Single
120VAC or 220VAC
1kw, 1.5kw, 2kw, 3kw, 4kw, 5kw, 6kw
50Hz, 60Hz
12VDC, 24VDC, 48VDC
18000W
70AMP
Overload Short Circuit Over Temp etc
24 Months
1kw 2kw 3kw 4kw 6kw Pure Sine Wave Solar Inverter
AC/DC Voltage Battery Status Loadetc
ZLPOWER, POWERSTAR
Wooden Carton
CE, ISO9001, RoHS
Shenzhen, China
8504403090
Product Description

220vac 48vdc 6000W Pure Sine Wave Inverter Charger UPS
PURE SINE WAVE INVERTER
1. Max 70A charge current
2. Compatible with generator
3. For Solar, Home, Airconditioner, Generator and so on
POWERSTAR PURE SINE WAVE INVERTER WITH CHARGER
This equipment is suitable to use in family, and under special environments, the equipment can connect to perceptual load such as air conditioner, laser printer. Stability of this equipment is good, the charging current is big and the charge rate is also very high. The output wave for this equipment sine wave.


Features:
LED Display
Buzzer Alarm
Over-Load Protection
Over-Voltage Protection
Low-Voltage Protection
Over-Temperature Protection
Short-circuit protection
Pure sine wave inverter charger Product Series | LW1000 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 | |
General Specification | Input Wave form | Sine wave (Utility or Generator) | |||||
Nominal voltage | 120VAC | 230VAC | |||||
Low voltage trip | 90v + 4% | 184v/154v + 4% | |||||
Low voltage reconnect | 100v + 4% | 194v/164v + 4% | |||||
High voltage trip | 140v + 4% | 253v + 4% | |||||
High voltage reconnect | 135v + 4% | 243v + 4% | |||||
Max input AC voltage | 150VAC | 270VAC | |||||
Nominal input frequency | 50Hz or 60Hz (Auto detect) | ||||||
Low freq trip | 47Hz for 50Hz, 57Hz for 60Hz | ||||||
High freq trip | 55Hz for 50Hz, 65Hz for 60Hz | ||||||
Output wave form | (Bypass mode) same as input | ||||||
Overload protection | Circuit breaker | ||||||
Short circuit protection | Circuit breaker | ||||||
Transfer switch rating | 30amp or 40amp | ||||||
Efficiency on line transfer time | 95%+ | ||||||
Line transfer time | 10ms Typical | ||||||
Bypass without battery connected | yes | ||||||
Max bypass current | 30amp or 40amp | ||||||
Bypass overload current | 35amp or 45amp: Alarm | ||||||
Inverter Specification Output | Output wave form | Pure sine wave | |||||
Output continuous power watts | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | |
Output continuous power VA | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | |
Power factor | 0.9-1.0 | ||||||
Nominal output voltage rms | 120/230VAC | ||||||
Output voltage regulation | 10% rms | ||||||
Output frequency | 50Hz + 0.3Hz or 60Hz + 0.3Hz | ||||||
Nominal efficiency | > 88% | ||||||
Surge ratings | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Short circuit protection | Yes, fault after 10 seconds | ||||||
Inverter Specification Input | Nominal input voltage | 12V | 24V | 48V | |||
Minimum start voltage | 10V | 20V | 40V | ||||
Low battery alarm | 10.5V | 21V | 42V | ||||
Low battery trip | 10V | 20V | 40V | ||||
High voltage alram | 16V | 32V | 64V | ||||
Power saver | Below 25watts when enabled | ||||||
Power saver | Same switched on/off on remote | ||||||
Charge Mode Specification | Input voltage range | 95-127VAC | 194-243VAC/ 164-243VAC(W) | ||||
Output voltage range | Dependent on battery type | ||||||
Charge current | 35A/70A | ||||||
Battery initial voltage for start up | 0-15.7v for 12v (*2 for 24v; *4 for 48v) | ||||||
Over charge protection shutdown | 15.7v for 12v (*2 for 24v; *4 for 48v) | ||||||
Others | Remote control/RS232/USB | Yes, Optional | |||||
Size: in mm | 1000/2000/3000 Model: 442*218*179 | ||||||
4000/5000/6000 Model: 598*218*179 | |||||||
Net weight | LW1000 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 | |
18kgs | 20kgs | 22kgs | 35gs | 38kgs | 40kgs |





One-stop service the price, quality, service, and after-sales service are all things you need are provide. We are factory direct sales, wholesale and retail are acceptable, good quality and the price is favorable to help your business.