Standard:
IEC60502, BS6346, VDE, AS/NZS, UL, etc
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
Application:
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
TYPE | NAME | Main Application | |
CU core | AL core | ||
YJV/YJY | YJLV/YJLY | XLPE insulated,PVC/PE sheathed power cable | For laying indoor ,tunnel,canal and underground. |
YJV22/YJV23 | YJLV22/YJLV23 | XLPE insulated,steel tape armored, | For laying indoor ,tunnel,canal and underground. |
YJV32/YJV33 | YJLV32/YJLV33 | XLPE insulated,thin steel wire armored, | For laying in shaft,water underground will large difference of level. |
YJV42/YJV43 | YJLV42/YJLV43 | XLPE insulated,thick steel wire armored, | For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
Specification
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Alum Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
1x4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
1x6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
1x10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
1x16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
1x25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
1x35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
1x50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
1x70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
1x95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
1x120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
1x150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
1x185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
1x240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
1x300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
1x400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
1x500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
2x1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
2x2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
2x4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
2x6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
2x10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
2x16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
2x25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
2x35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
2x50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
2x70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
2x95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
2x120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
2x150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2x185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
2x240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
2x300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
2x400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
3x1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
3x2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
3x4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
3x6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
3x10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
3x16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
3x25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
3x35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
3x50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
3x70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
3x95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
3x120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
3x150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
3x185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
3x240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
3x300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
3x400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
mm² | mm | mm | mm | mm | mm | mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
3x120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
3x150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
3x185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
3x240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
3x300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
4x1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
4x2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
4x4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
4x6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
4x10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
4x16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
4x25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
4x35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
4x50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
4x70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
4x95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
4x120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
4x150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
4x185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
4x240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
4x300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
4x400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv) Item | 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |

cable enterprise group that integrates manufacturing,
sales, design, and research and development. The company mainly produces a variety of specifications
including rubber-sheathed flexible cables, marine cables, control cables, special cables,
mining cables, welding machine cables, environmentally friendly, flame-retardant, fire-resistant power cables,
PVC insulated non-sheathed cables, pre-branched cables, aluminum alloy cables,
and high and low voltage cross-linked polyethylene power cables.
These products are widely used in industries such as machinery manufacturing,
petroleum exploration, electrical equipment, fire engineering, construction, metallurgy,
and agricultural irrigation. Over the years, Shenxing Group has established good
relationships with different customers by relying on stable quality to meet their needs.
Facing new market competition, the trend of economic integration, and significant scientific and technological
development, Shenxing Group integrates human resources and brand resources, actively establishes industrial
cooperation alliances, and is committed to building an international cable group that integrates advanced
production technology, advanced process equipment, and advanced management models from both domestic
and international sources,
continuously providing high-quality products and services to improve people's quality of life.

The company has a registered capital of 5.18 billion yuan and covers an area of 65,000 square meters.
It currently possesses a variety of leading domestic and foreign testing instruments and equipment,
along with a comprehensive testing system. This ensures that Shenxing cables have excellent quality
upon leaving the factory, earning widespread recognition from customers both domestically and
internationally. The guarantee of equipment, staffing, and system perfection is the reason why
"Shenxing" brand wires and cables have a high market share. Adhering to a professional spirit to
achieve strict product monitoring is not only a strong guarantee of product quality but also a powerful
maintenance of the brand itself.
The company was ranked among the top 20 enterprises in Jinzhou City. In 2000, it was rated as an AAA
credit unit by the banking sector. In 2001, it was recognized by the commercial sector as a trustworthy unit
for contract compliance and consumer trust. In 2002, it obtained the IS09001 international quality system
certification. In 2003, it received the CCC national mandatory product certification. In 2006, it obtained the
national industrial product license. In the same year, the "Shenxing" brand cables were selected as a "China
Famous Brand". In 2010, it was awarded the safety mark certificate for mining products and recognized as
a "Star Enterprise in Shijiazhuang City". It is an enterprise with independent import and export rights and uses
international product logo certification. In 2011, it was awarded the title of "Best-selling Brand with High
Quality and Good Reputation in Hebei Province" and "Anti-counterfeiting and Genuine Integrity Unit". In
2012, it was honored as a "Famous Trademark in Hebei Province". In 2013, it was recognized as a "Model
of Integrity Management in Hebei Province", a "Star Enterprise", and a "Key Recommended Enterprise on
National Consumer Rights Day on March 15". In 2014, it was awarded the title of "Consumer