Product Description
6~35kv Cable Accessories Classification Introduction
Explore our range of cutting-edge cable solutions: 4E-NLS Cold Shrinkable Indoor Termination, 4E-WLS Cold Shrinkable Outdoor Termination, and 4E-JLS Cold Shrinkable Joint. These innovations ensure unmatched reliability and performance in all settings.
The 4E-NLS cold shrinkable technologyindoor termination, and the 4E-WLS cold shrinkable solutionoutdoor termination, along with the 4E-JLS cold shrinkablemiddle joint, form an integral part of our advanced electrical solutions. These components are mainly composed of a prefabricated body, terminations (catering to both indoor and outdoor needs) or connecting tube (middle joint) cold shrinkablemulti-core fingerstall (ideal for supporting multi-core cables), and cold shrinkableinsulation tubes along with relative colormetric tubes (suitable for both indoor and outdoor termination). The prefabricated body stress cone and insulating body leverage the precision of plastic injection molding using liquid silicone rubber, ensuring the long-term stability of the package's tight force and a uniform electric field capacity. It consistently maintains an optimal radial pressure to the cable body, with excellent interface characteristics that prevent respiration creepage breakdown during cable operation. The terminations or connecting tubes are meticulously designed to meet cable core material requirements as well as user specifications, ensuring comprehensive protection of cable insulation and waterproofing.

Main Structure Features:
Premium raw materials: Our prefabricated bodies are crafted from high-quality liquid silicone, delivering outstanding insulation, elongation, and breakdown properties, with minimal residual deformation post-expansion.
Cold shrinkablestructure: Utilizing the latest expansion equipment and support tubes, we ensure flawless product expansion without any damage.
Effortless installation: The cold shrinkableexpansion structure requires no specialized training, reducing labor costs with its straightforward, convenient installation.

6~35kV Cold Shrinkable Outdoor Termination


  1. Lug2. Marking tube3. Cable insulation 4. Cold shrinkable termination 5. Stress cone6. Insulation screen layer7. Copper screen8. Cold shrinkable protective tube 9. Three fingered tube 10. Copper braid wire
Size mm8.7/15kV12/20kV18/30kV26/35kV
L252370370450
A≥800≥950≥950≥1300
Voltage
Section number
1234
8.7/1525-5070-120150-240300-400
12/20,18/30,26/3550-95120-185240-400500-630

6~35kV Cold Shrinkable Indoor Termination

  1. Lug2. Marking tube3. Cable insulation 4. Cold shrinkable termination 5. Stress cone6. Insulation screen layer7. Copper screen8. Cold shrinkable protective tube 9. Three fingered tube 10. Copper braid wire 11. Cable
Size mm8.7/15kV12/20kV18/30kV26/35kV
L180288288370
A≥700≥850≥850≥1200
Voltage
Section number
1234
8.7/1525-5070-120150-240300-400
12/20,18/30,26/3550-95120-185240-400500-630

6~35kV Cold Shrinkable Middle Joint

  1. Copper screen2. Constant force spring3. Stress cone 4. Connecting tube 5. Prefabricated main body6. Copper net7. Braid wire8. Armour tape 9. Armour 10. Cable
Size mm8.7/15kV12/20kV18/30kV26/35kV
L378430430488
A1300160016001800
Voltage
Section number
1234
8.7/1525-5070-120150-240300-400
12/20,18/30,26/3550-95120-185240-400500-630

6~35KV cold shrinkableindoor,outdoor termination, and joint electrical performance parameters.
Rated voltage UO/U (Um) kV6/10(12.5)8.7/15(17.5)26/35(40.5)Railway Uo=27.5Test result
5min frequency voltage testno flashover, without breakdown under 4.5Uono flashover, without breakdown
1min frequency voltage under rain test
no flashover, without breakdown under 4Uo
no flashover, without breakdown
Partial discharge at room temperature testdischarge volume under 1.73Uo ≤10PC≤1.6pC
Constant voltage load cycle in the air testheated 2.5Uo and conductor to a temperature to 95-100°C three times, no flashover, without breakdownno flashover, without breakdown
Partial discharge at high temperature testheated cable conductor to 95-100°C,discharge volume under 1.73Uo ≤10PC≤1.6pC
Partial discharge at room temperature testdischarge volume under 1.73Uo ≤10PC≤1.6pC
Impulse voltage at high temperature test75kV 95kV200kV25kVno flashover, without breakdown
heated cable conductor to 95-100°C,both positive and negative polarity 10 times, no flashover, without breakdown
Constant voltage load cycle testheated 2.5Uo and conductor to a temperature to 95-100°C sixty times, no flashover, without breakdownno flashover, without breakdown
Partial discharge at high temperature testheated cable conductor to 95-100°C,discharge volume under 1.73Uo ≤10PC≤1.6pC
Partial discharge at room temperature testdischarge volume under 1.73Uo ≤10PC≤1.6pC
Impulse voltage test75kV 95kV200kV250kVno flashover, without breakdown
both positive and negative polarity 10 times, no flashover, without breakdown
15min frequency voltage testno flashover, without breakdown under 2.5Uono flashover, without breakdown
Outdoor termination salt spray test1.25Uo,1000h,no flashover, without breakdown, no significant electrical corrosion and mechanical damageno flashover, without breakdown
Indoor termination wet test1.25Uo,300h,no flashover, without breakdown, no significant electrical corrosion and mechanical damageno flashover, without breakdown