Professional Disposal System Infectious Medical Waste Treatment with Shredder Sterilizer Two in One

Price $60000.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 445 people viewed
Quantity
+-
 

Jiangsu Rooe Medical Technology Co., Ltd.

VIP   Audited Supplier 13 years
Profile Certified by SGS/BV
MCDS
Pressure Steam
Pressure Steam Sterilization Equipments
CE, FDA
380V
With LCD Display
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Stainless Steel
WANROOEMED
Export Carton Package
CE, ISO
China
84192000
Product Description

MCDS Professional Disposal System Infectious Medical Waste Treatment with Shredder Sterilizer Two in One

MCDS Intelligent Medical Waste Steam Autoclave System

Introduction:

The system enables automatic discharge, sterilization, crushing, orbital transport, cleaning, and palletizing of the system. Automatic control, no need to manually intervene, effectively reduce the number of operators, reduce labor intensity, and eliminate infections caused by direct contact with medical waste.

 

MCDS Medical Waste Steam Autoclave

Sterilization principle:

protein denaturation, which will all kill all microorganisms,including bacterial spores.

The device uses a high-temperature steam sterilization of medical waste processing methods, namely heat sterilization.Saturated steam as the working medium, using its strong penetration deep into the sterilized items inside and release the latent heat of steam contained, so that rapid warming sterlized objects remain for some time after reaching the sterilization temperature, bacteria coagulation.

 

Sterilization Procedure:

Prepare--Pulse--Warm up--Sterilize--Vent--Dry--Finish

 

Sterilization System Features:

1. Biological safety seal items
The sterilizer fully realizes complete shielding of the sterilization process sterilizing articles, sterilization exhaust steam generated in the process wastewater effectively inactivated.
2.Seal doors
When environmental security needs, the use of compressed air to pass into the ring, can ensure the safety of the door seal.This prevents leakage in the box and out of the cabinet area. Seal the door when a power cut, such as failure, you can still remain sealed;
3.Quality and efficient import filters
4.Treatment of high-risk waste
5.Cavity structure
The top of the vacuum through the filter, the lower portion of the steam from the sterilizer to enter, the condensate is maintained at the top and bottom of the cavity of the cavity bottom of the steam inlet, the entire strilization process, condensed water heated by steam, to achieve sterilization temperature. Strilization process, the steam is continuously withdrawn from the top through the filter,after the sterilization, the sterilized water is drained from the bottom of the condensate.

 

Handling System

Handling systems include manual handling systems and automated handling systems

 

Manual handling system:

Introduction: 

Manual handling system is laying track on the ground, the material transmitted through human.The system consists of a linear transport to rail,bridge and other turntable and out of the cabinet.

Automated handling systems:

Introduction: 

Medical waste handling systems include automatic Crate automatic handling systems and sterilization car automatic handling systems.Crate automatic handling system includes automatic feeder, linear transfer unit (including chain conveyors and roller conveyors),90 °steering unit,180 ° flip units,etc. Sterlization car automatic handling systems including linear transfer unit (roller conveyor), 90 °steering unit,automatic cabinet unit, automatic cabinet unit, automatic unloading machine.

System features:

The ability to achieve automatic feeding of medical waste,discharge,sterilization car automatic transmission automatic transmission and IBC cleaning, without human intervention,which can effectively reduce the number of equipment operators, reduce labor intensity.Put an end to people in direct contact with medical waste caused by infection.

 

Medical waste shredder

Double shaft shredder extrusion-type structure,the use of two cutting blades for cutting works,minced cut waste. Mainly from the power system, frame,drive shafts, blades,hoppers and other components.

Features:

1. simple structure,each workpiece mounting compact, easy maintenance.
2.The control system can realize reversing arbor, protect the motor and blade, the
safety factor increases.
3.Bearing cap has oil cup, easy bearing lubrication.
4.The oil level sight glass can be easily observed in the level of the gear oil level.
5.Blade made of high alloy steel, fully machined, after repeated heat treatment and
surface hardening treatment to ensure its reliable mechanical properties.
6.Sparse stiffened oriented materials, and prevent back after the break with the
material.

 

Turnover box washing machine

Washing machine by the drive motors,conveyors, sprinker system and automatic control system.Loading crates of medical waste is placed in the automatic dleaning system of the rod mesh belt conveyor chains, motor starters, Crate belt is fed first by rinsing station,high-pressure rinse,rinse after the end of Crate and was transported to disinfection station, through the pump Crate full disinfectant spray all places, for disinfection.After the disinfectant spray,Crate also transferred to the cleaning station by a link belt, by high-pressure water spray washing disinfectant on Crate washed with water, and then send it to the end of the washing machine, this time Crate can be removed from the net to bring the final finishing to prepare for the next use.

 
Company Information:
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA