IP68
Cable Joint
PE
1~5-Cores
Pass
GB811-P5
LV & Mv (up to 35kv)
-50 ~105
9V
Carton
Varous
Jiangsu, China
8547909000
Product Description
Product Description

Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.

Detailed Photos
 
Product Parameters

0.6/1KV-Heat Shrinkable Cable Accessories

NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
0.6/1kV Single Core Heat Shrinkable Termination KitsVSZ-1/1.010~160.6/1kV Single Core Heat Shrinkable JointVSJ-1/1.010~16
VSZ-1/1.125~50VSJ-1/1.125~50
VSZ-1/1.270~120VSJ-1/1.270~120
VSZ-1/1.3150~240VSJ-1/1.3150~240
VSZ-1/1.4300~400VSJ-1/1.4300~400
0.6/1kV 2-cores Heat Shrinkable Termination KitsVSZ-1/2.010~160.6/1kV 2-cores Heat Shrinkable JointVSJ-1/2.010~16
VSZ-1/2.125~50VSJ-1/2.125~50
VSZ-1/2.270~120VSJ-1/2.270~120
VSZ-1/2.3150~240VSJ-1/2.3150~240
VSZ-1/2.4300~400VSJ-1/2.4300~400
0.6/1kV 3-cores Heat Shrinkable Termination KitsVSZ-1/3.010~160.6/1kV 3-cores Heat Shrinkable JointVSJ-1/3.010~16
VSZ-1/3.125~50VSJ-1/3.125~50
VSZ-1/3.270~120VSJ-1/3.270~120
VSZ-1/3.3150~240VSJ-1/3.3150~240
VSZ-1/3.4300~400VSJ-1/3.4300~400
0.6/1kV 4-cores Heat Shrinkable Termination KitsVSZ-1/4.010~160.6/1kV 4-cores Heat Shrinkable JointVSJ-1/4.010~16
VSZ-1/4.125~50VSJ-1/4.125~50
VSZ-1/4.270~120VSJ-1/4.270~120
VSZ-1/4.3150~240VSJ-1/4.3150~240
VSZ-1/4.4300~400VSJ-1/4.4300~400
0.6/1kV 5-cores Heat Shrinkable Termination KitsVSZ-1/5.010~160.6/1kV 5-cores Heat Shrinkable JointVSJ-1/5.010~16
VSZ-1/5.125~50VSJ-1/5.125~50
VSZ-1/5.270~120VSJ-1/5.270~120
VSZ-1/5.3150~240VSJ-1/5.3150~240
VSZ-1/5.4300~400VSJ-1/5.4300~400
Test ProjectTest MethodTest Result/Conclusion
1min Power Frequency Voltage (wet state)4kV, No breakdown no flashoverNo flashover and breakdown of the combined sample under 4kV, 1min wet state
Heating Cycles Voltage TestConductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cyclesComplete three load cycle tests as required by the standard
4H Power Frequency Voltage Test2.4kV, No breakdown no flashoverNo flashover and breakdown of combined specimens
8.7/15KV-Heat Shrinkable Cable Accessories
NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
8.7/15kV Single Core Heat Shrinkable Indoor Termination KitsVRSN-10/1.125~508.7/15kV 3-cores Heat Shrinkable Indoor Termination KitsVRSN-10/3.125~50
VRSN-10/1.270~120VRSN-10/3.270~120
VRSN-10/1.3150~240VRSN-10/3.3150~240
VRSN-10/1.4300~400VRSN-10/3.4300~400
VRSN-10/1.5500~630VRSN-10/3.5500~630
8.7/15kV Single Core Heat Shrinkable Outdoor Termination KitsVRSW-10/1.125~508.7/15kV 3-cores Heat Shrinkable Outdoor Termination KitsVRSW-10/3.125~50
VRSW-10/1.270~120VRSW-10/3.270~120
VRSW-10/1.3150~240VRSW-10/3.3150~240
VRSW-10/1.4300~400VRSW-10/3.4300~400
VRSW-10/1.5500~630VRSW-10/3.5500~630
8.7/15kV Single Core Heat Shrinkable JointVRSJ-10/1.125~508.7/15kV 3-cores Heat Shrinkable JointVRSJ-10/3.125~50
VRSJ-10/1.270~120VRSJ-10/3.270~120
VRSJ-10/1.3150~240VRSJ-10/3.3150~240
VRSJ-10/1.4300~400VRSJ-10/3.4300~400
VRSJ-10/1.5500~630VRSJ-10/3.5500~630
Test ProjectStandard RequirementsTest Result/Conclusion
1min Power Frequency Voltage (wet state)45kV, No breakdown no flashoverNo flashover and breakdown of the combined sample under 45kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC13kV≤20PCA, B, C three-phase discharge capacity is 2PC under 13kV
Heating Cycles Voltage TestConductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cyclesComplete three load cycle tests as required by the standard
Impulse Voltage Test105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen105kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test52kV, No breakdown no flashover52kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test35kV, No breakdown no flashover35kV, 4h, No flashover and breakdown of combined specimens

12/20KV 18/20KV-Heat Shrinkable Cable Accessories
 
NameSpec. (Single Core)Spec. (3-cores)Suit cables' sectional area (sqmm)
12/20kV18/20kV
12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination KitsVRSN-20/1.1VRSN-20/3.135~70------
VRSN-20/1.2VRSN-20/3.295~18535~70
VRSN-20/1.3VRSN-20/3.3240~40095~185
VRSN-20/1.4VRSN-20/3.4500~630240~400
12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination KitsVRSW-20/1.1VRSW-20/3.135~70------
VRSW-20/1.2VRSW-20/3.295~18535~70
VRSW-20/1.3VRSW-20/3.3240~40095~185
VRSW-20/1.4VRSW-20/3.4500~630240~400
12/20kV Single Core / 3-cores  Heat Shrinkable JointVRSJ-20/1.1VRSJ-20/3.135~70------
VRSJ-20/1.2VRSJ-20/3.295~18535~70
VRSJ-20/1.3VRSJ-20/3.3240~40095~185
VRSJ-20/1.4VRSJ-20/3.4500~630240~400
Test ProjectStandard RequirementsTest Result/Conclusion
1min Power Frequency Voltage (wet state)54kV, No breakdown no flashoverNo flashover and breakdown of the combined sample under 54kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC20kV≤20PCA, B, C three-phase discharge capacity is 1pc under 20kV
Heating Cycles Voltage TestConductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cyclesComplete three load cycle tests as required by the standard
Impulse Voltage Test125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen125kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test156kV, No breakdown no flashover156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test104kV, No breakdown no flashover104kV, 4h, No flashover and breakdown of combined specimens
 
26/35KV-Heat Shrinkable Cable Accessories
NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
26/35kV Single Core Heat Shrinkable Indoor Termination KitsVRLN-35/1.150~9526/35kV 3-cores Heat Shrinkable Indoor Termination KitsVRLN-35/3.150~95
VRLN-35/1.2120~185VRLN-35/3.2120~185
VRLN-35/1.3240~400VRLN-35/3.3240~400
VRLN-35/1.4500~630VRLN-35/3.4500~630
26/35kV Single Core Heat Shrinkable Outdoor Termination KitsVRLW-35/1.150~9526/35kV 3-cores Heat Shrinkable Outdoor Termination KitsVRLW-35/3.150~95
VRLW-35/1.2120~185VRLW-35/3.2120~185
VRLW-35/1.3240~400VRLW-35/3.3240~400
VRLW-35/1.4500~630VRLW-35/3.4500~630
26/35kV Single Core Heat Shrinkable JointVRLJ-35/1.150~9526/35kV 3-cores Heat Shrinkable JointVRLJ-35/3.150~95
VRLJ-35/1.2120~185VRLJ-35/3.2120~185
VRLJ-35/1.3240~400VRLJ-35/3.3240~400
VRLJ-35/1.4500~630VRLJ-35/3.4500~630
Test ProjectStandard RequirementsTest Result/Conclusion
1min Power Frequency Voltage (wet state)105kV, No breakdown no flashoverNo flashover and breakdown of the combined sample under 105kV, 1min wet state
Partial discharge test 13kV devolution power not more than 10PC39kV≤10PCA, B, C three-phase discharge capacity is 4pc under 39kV
Heating Cycles Voltage TestConductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cyclesComplete three load cycle tests as required by the standard
Impulse Voltage Test250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen250kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test156kV, No breakdown no flashover156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test104kV, No breakdown no flashover104kV, 4h, No flashover and breakdown of combined specimens
 
Recommended Product

View more products,you can click photos...

     66~500kV High Voltage Cable Accessories              1~35kV Cold Shrink Cable Accessories                                        Grounding Box

      Customized Silicone Rubber Protector                                Heat Shrinkable Tubing                                                  Explosion Proof Box

Company Profile
Packaging & Shipping

FAQ
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA