Proven Performance Indoor High Voltage Vcb for Power Systems

Price $1500.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 457 people viewed
Quantity
+-
 

Shanghai Kaiji Power Equipment Co., Ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
VCB-F
High Voltage Circuit Breakers
Manual Type or Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed or Insert
ACB
3
Circuit Breaker
Conventional Circuit Breaker
ISO9001-2000
Customizable
Yes
Old Fashioned Circuit Breaker to Figure Custom
7.2-12, 24, 36kv
VKJ
According to The Packaging Requirements of The Imp
1250A-31.5KA/4000A-50KA
China
8535210000
Product Description
Shanghai Kaiji Power Equipment Co., Ltd,which is located at #777 Yuegong Road, Jinshan Industrial Zone, Shanghai, is in the core area of "Yangtze River Delta". The unique location advantage builds good development platform and make manufacturing capacity and quality assurance capabilities to reach the international leading level.
Shanghai Kaiji specializes in manufacturing different kind of indoor high voltage vacuum circuit breakers, the main products are VKJ series with 7.2 KV - 24 KV - 35 KV and special circuit breaker lift vehicles.
Based on quality for growth, technology for development and service for market, our company always insists on such business philosophy. Shanghai Kaiji is willing to work with friends from home and abroad to develop together and win-win cooperation.
Detailed Photos
 
Product Parameters

Technical data

 
    1. Main technical parameters of Model VKJvacuum breaker 
Table 1
 
No.Parameter designation UnitData
1Rated voltage kV12
2Rated insulation levelPower frequency withstand voltage at 1 minkV42
Rated lightning impulse withstand voltage kV75
3Rated current A630100012501600200025003150
4Rated short circuit breaking current (effective value)
Rated short time withstand current (effective value)
kA202020    
25252525   
 31.531.531.531.5  
  4040404040
   50505050
5
 
Rated short circuit closing current (peak value)
Rated peak withstand current  (peak value)
kA505050    
63636363   
 80808080  
  100100100100100
   125125125125
6Rated short circuit breaking current breaking timesTimes30.50x
7Rated short circuit duration s1
8Rated operating sequence O-0.3s-CO-180s-CO
9Mechanical lifeTimes30000
10Rated single capacitor bank breaking currentA630
11Rated back to back capacitor bank breaking currentA400

Note:
  1. When rated short circuit breaking current 31.5kA, rated short circuit breaking times is 50 times.
When rated short circuit breaking current >31.5kA, rated short circuit breaking times is 30 times.
  1. When rated short circuit breaking current is 50kA, rated operating sequence is: O-180s-CO.180s. CO.
 
    1. Mechanical characteristic parameters after breaker is assembled and adjusted
Table 2
 
No.Parameter designationUnitData
1Contact opening distancemm11±1
2Contact travelmm3.5±0.5
3Three phase switch on/off asynchroneity 2
4Bounce time of switch-on contactms2(for 40kA and above ≤3) a
5Center distance between phasesmm210±1.5 (275+1.5)  a
6Rated short circuit breaking currentkA202531.54050
7Contact pressure of switch-on contactN2000±2002400±2003100±2004500±2006000±200
8Average switch-off speedm/s0.9~1.3
9Average switch-on speedm/s0.5~0.9
10Breaking timems30±10
11Closing timems50±10
12Main circuit resistance in each phase of breaker bµΩ40
13Main circuit resistance in each phase of breaker and cart cµΩ≤55
14Bounce range of contact switch-offmm≤1
15Allowable abrasion thickness of dynamic and static contactmm≤3

Note:
  1. What in the parentheses is for product with rated current of 2500A and above.
  2. Main circuit resistance of breaker is resistance between upper and lower outgoing lines.
  3. Main circuit resistance of breaker cart is the resistance between upper and lower moving contacts.
 
    1. See Figure 3 and Table 3 for parameters of draw-out type breaker unit with binding type primary contact:
Table 3
 
Rated voltage (kV)121212121212
Rated current A630/10001250160020002500/31504000/5000
Moving contact arm closing circle D1284248/7272102102
Static contact arm closing circle D2354955/7979109109
Diameter of max. excircle D3748794/128128158158
Number of moving contact stylus243036/48486482


Figure 3 Dimensions Related to Fitting of Moving and Static Contacts

 
    1. See Figure 4 for schematic diagram of secondary wiring of vacuum breaker:

Actuator of this breaker could be driven by AC or DC.
 
    1. Technical data of energy storage motor

This product adopts permanent-magnet type single direction DC motor with special speed reducer; change gear in the reducer is enclosed in a case filled with lubricating grease, output speed is 10r/min. Torque 25N.m. See the following Table 4 for technical parameters of motor.

Table 4

 
ModelRated voltage (V)Rated output power (W)Normal working voltage range (V)Energy storage time at rated voltage (s)
HDZ-70-30BDC110
DC220
8085%-110% rated voltage15
Note: Allow AC/DC power supply for operation
 
    1. See Figure 5 for technical data of switching on/off electromagnet
 Switch on/off electromagnet
Rated operating voltage (V)DC220DC110
Coil power (W)244366
Rated current (A)1.113.33
Current resistance (Ω)19833
Operating voltage range Switch off 65%-120% rated voltageswitch on 85%-110% rated voltage