Qd6000 One-to-Two-Channel Gas Alarm for Flammable Gas

Price $1000.00 Compare
Min Order 1 Set
Shipping From Chongqing, China
Popularity 293 people viewed
Quantity
+-
 

Chongqing Jiuxin Automation Technology Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
JX-GA4
Gas Alarm
Factory
%Lel, %Vol, Ppm
3%Fs
4-20mA
Two-Level Alarm, Can Be Freely Set by
(Ex) Low Report: 20%Lel High Report:
LED Digital Display Concentration
Switch, Max 3.0A
on-Site Fixed Installation, Wall-Mo
1 Channel 2 Channels
Monitor Max 6W Sensor Max 1W
GB16808-2008
J&X
Wooden Case
China
9027100090
Product Description

QD6000 One-to-Two-Channel Gas Alarm

 

Brief description: 
One-to-two gas alarm is used to detect the content of flammable gas or liquid vapor in the air within the lower explosion limit. It can be equipped with multiple detection probes and centrally control multiple points at the same time. This system uses a microprocessor as the control unit and a high-performance catalytic gas sensor as the detection sensor, which has high sensitivity and fast response speed.
QD6000 one-to-two-channel gas alarm is used to detect the content of flammable gas or liquid vapor in the air within the lower explosion limit. It can be equipped with multiple detection probes and centrally control multiple points at the same time. This system uses a microprocessor as a control unit and a high-performance catalytic gas-sensitive element as a detection sensor, which has high sensitivity and fast response speed. When the concentration of flammable gas in the environment reaches or exceeds the preset alarm value, the controller immediately issues an audible and visual alarm and drives the exhaust or other peripherals to prevent explosions and fire accidents, thereby protecting lives. This system can be widely used in factories, oil depots, liquefied gas stations, gas stations, gas stations, paint spraying rooms and other places that require fire and explosion prevention for safety detection and alarm.

product features:

Measurement range%LEL, %VOL, PPM
Accuracy±3%FS;
Sensor signal4-20MA
Alarm pointTwo-level alarm, can be freely set by the user
Default value(EX) Low report: 20%LEL High report: 50%LEL
Indication modeLED digital display concentration data, LED indication alarm or fault status
Output modeswitch, MAX 3.0A
Working methodOn-site fixed installation, wall-mounted
Network capacity1 channel 2 channels
Working environmenttemperature -20 - 50ºC humidity < 95%RH,
Working voltageAC220V±l0% 50HZ
PowerMonitor Max 6W Sensor Max 1W
Implementation standardGB16808-2008
Requirements for the connection line between the system and the external (gas) detectorstandard 3-wire connection method, single-core wire diameter ≥ 1.5mm, wire length ≤ 1000m.

 

 
 