LINK812C
Two Years
Two Years
Digital
Direct Connected
Multi-Functional Energy Meter, Meter for Industry and Home Use, Prepayment Meter
Three-phase Four-wire
Electric Apparatus
Continuous Wave
Power Meter
ISO
Customized
Linkelec
Made in China
Product Description
Rail type dual phase meter
1.Product Introduction
This product is mainly used in the field of electricity information collection for three-phase power networks with frequencies ranging from 45 to 65Hz. It can measure all electrical parameters in the power grid and exchange data with the upper computer through communication. Users can set the internal parameters of the product according to the actual situation on site, which is convenient to use, easy to operate, and has high accuracy; Widely used in various power ubiquitous IoT usage scenarios.
It can achieve high-precision measurement and metrology to meet measurement and other applications. Adopting standard DIN35mm rail installation and modular structural design, it can be easily installed inside the distribution box. Users can easily switch displays and set parameters on-site, making it flexible and convenient to use. It can directly replace conventional power transmitters and other auxiliary units as an advanced intelligent digital power grid front-end acquisition component, widely used in various control systems, substation automation systems, and distribution automation systems. It has the characteristics of easy installation, simple wiring, convenient maintenance, and small engineering quantity, and can flexibly network with various communication software.

 
2.Technical parameter
Performance pointPerformance index
input voltagerated voltage220V AC
frequency range 45~65Hz
overload capacity1.2Un (continuous); 2Un (10s allowed)
measuring range0.5 Un~1.2Un
Power consumption< 0.3VA per loop
incoming currentrated current5(60)A 
overload capacity1.2In (continuous); 20In (1s allowed)
measuring range0~1.2Imax, and the threshold value is 50mA.
Power consumption< 0.5VA per loop
working power supplyOperating voltage range0.7 Un~1.2 Un 
Power consumption<2.5W,5VA
Internal relayMaximum switching current80A
communication interfaceInterface formHalf duplex, optical isolation, RS485 interface
Address range1~247
protocolModbus-RTU
Communication baud rate2400~19200bps, the default is 9600bps.
environmental conditionsWorking temperature -20ºC~70ºC
storage temperature -40ºC~70ºC
Working humidity0 ~ 95% does not condense.
atmospheric pressure86kPa~106kPa
mechanical charactervibrateGB/T 11287 severity level 1
lashGB/T 14537 severity level 1
collideGB/T 14537 severity level 1
Electromagnetic compatibility performanceRadio frequency electromagnetic field immunity test GB/T 17626.3-2006 Severity Grade 3
Electrical fast transient test GB/T 17626.4-2008 Severity Grade 4
Attenuated oscillation wave immunity test Severity grade 3-12-1998
Electrostatic discharge test GB/T 17626.2-2006 Severity Grade 4
Surge immunity GB/T 17626.5-2008 Severity Grade 4
Radio frequency conduction immunity GB/T 17626.6-2008 Severity Grade 3
radio disturbance GB/T 17215.211-2006 7.5.8 Class B Equipment
Interference degree of power frequency magnetic field GB/T 17626.8-2006 Severity Grade 3
Electrical insulation performanceinsulanceGBT 13729-2002, not less than 100MΩ.
dielectric strengthGB/T 13729-2002, power frequency voltage 2kV, 1 minute.
surgingGB/T 13729-2002,1.2/50μs,5kV
 
3.Selection specifications
functional moduleS/NFunction pointFunction Point DescriptionLINK812C
Single-phase rail prepayment meter
real-time measurement1VoltagePhase voltage: U
2electric currentPhase current: IA, IB
3Active powerActive power: PA, PB, P
4Reactive powerReactive power: QA, QB, Q
5Apparent powerApparent power: SA, SB, S
6power factorPower factor: PFA, PFB, PF
7frequencySystem frequency: f
Electricity metering8Active kilowatt hourBidirectional active energy of each loop
9Reactive kilowatt hourBidirectional reactive energy of each loop
Multiple rate10time zoneSupports up to 4 time zones.-
11time intervalUp to 4 daily time slots are supported, and each daily time slot supports up to 8 time slots.
12rateUp to four rates, namely, peak, flat and valley, are supported.
13Multiple rate kilowatt hourForward/reverse active complex rate electricity
Prepayment14call the Prepayment has an alarm function, and the alarm threshold can be set. When the remaining amount/power is less than or equal to the threshold, an alarm will be given to remind users to recharge in time.
15get creditCan realize credit function, credit threshold can be set.
frozen16Monthly freezeThe freezing day of the month can be set from 1 to 28, and the electric energy of this month can be automatically recorded at the zero point of the setting day of each month, which can be recorded for 12 consecutive months.-
17Daily freezeThis month's electric energy can be automatically recorded at 0: 00 every day, which can record the recent 90 days' electric energy continuously.-
Telesignalling18Over limit alarmRemote communication state with 8-level out-of-limit alarm-
19Prepaid statusAlarm status such as insufficient balance and no balance.
Malignant load20Malignant load identificationTotal current limit, total power limit, single load power limit and malignant load limit can be realized.
exceed the time limit21Over limit alarm8-level over-limit alarm function, which can monitor power parameters and remote signal volume, generate an alarm when conditions are met, and can be linked with the exit of the alarm.
Event record22SOE recordIt has 64 SOE recording functions, including remote control, recharge and other records, and records with time scales.
23Record of maximum valueThe maximum and minimum values of relevant parameters (voltage, current, active power, reactive power, apparent power, power factor and frequency) can be counted in real time, and recorded with time scales.
Clock24ClockAccurate clock with hardware
Input and output25Built in relayOptional built-in relay to realize opening and closing.
26Pulse outputWith active energy pulse output port, used for accuracy detection of electric energy meter.
communication interface27RS485 communication1 RS485 communication, supporting MODBUS-RTU protocol; Support online upgrade program through RS485 interface.
28NB CommunicationSupport NB communication mode
29telecommunicationsSupport wireless communication and MODBUS-RTU protocol.

4.Product perforation and installation diagram

5.About our service :                
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.


6.Delivery Diagram
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA