Real Time Energy Data Collection and Monitoring Gateway

Price $300.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 325 people viewed
Quantity
+-
 

Nanjing Linkelec Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
LON3112
Adjust
Combination
Linear
Continuous
ISO: 9001
New
Customized
Spray Coated Galvanized Sheet
Linkelec
Made in China
8517623990
Product Description
                                  LON3112 Communication Management Device
 
1.Summary
The LON3112 series is an industrial grade Nuvoton processor based on RISC architecture, with a clock speed of 300MHz, supports 1 channel of 10/100Mbps adaptive industrial Ethernet interface, 2 channels in series Port (RS-232/422/485), 1 debugging serial port, using high performance, low power consumption, small size Embedded computer with 128MB DDR2 SDRAM and 4G Flash memory embedded in the volume, as well as SD storage with a capacity of up to 128GB, it has powerful computing and storage capabilities Local and remote wireless communication capabilities. Combined with rich peripheral interfaces and communication functions, it is often suitable for those who require high computing power Application scenarios such as data collection and control systems, communication systems, remote device monitoring, etc.

2.Major function 
2.1Signal communication
2.1.1 The LON3112 communication management device can communicate with the load monitoring device and collect and store electrical quantity data at set time intervals. Follow DL/T 645-2007 or DL/T 698.45-2017 protocol or Modbus RTU protocol.
2.1.2 LON3112 communication management device can communicate with the air conditioning communication control module, read the set temperature, operating status, and operating parameters of the air conditioning, and send air conditioning load adjustment strategies or air conditioning operating parameter adjustment instructions to the air conditioning management and monitoring system to change the air conditioning operating load.
2.1.3 LON3112 communication management device can communicate with smart sockets, copy and store electrical quantity data, set temperature, environmental temperature and humidity data at set time intervals, and send air conditioning set temperature adjustment instructions to smart sockets according to the requirements of air conditioning load regulation events.
2.1.4 LON3112 communication management device can communicate with independent environmental temperature and humidity sensors and collect environmental temperature and humidity data.
2.1.5 LON3112 communication management device can communicate with local maintenance tools through a local communication interface to achieve functions such as data query, parameter update, file download, program update, etc.

2.2Data acquisition
2.2.1 Electrical quantity data collection: LON3112 communication management device can collect electrical quantity data of air conditioning by reading the current data stored in load monitoring instruments and smart sockets.
2.2.2 Air conditioning operation parameters and air conditioning operation status data collection: LON3112 communication management device can collect the operation parameters and status of multi split and water circulation central air conditioning systems, and the collection interval can be set according to the demand of air conditioning load regulation business.

2.2.3 Air conditioning set temperature collection: The air conditioning set temperature is defined as the target ambient temperature of the relatively enclosed space where the end of the air conditioning system (indoor unit) is located. The LON3112 communication management device can collect the set temperature of split air conditioners and multi split system air conditioners. The LON3112 communication management device can collect the set values of the inlet and outlet water temperatures of the cold/warm water pipelines of water-cooled units and air-cooled heat pump units, and can assist in analyzing the indoor environmental temperature to calculate the set temperature of the air conditioner. The collection interval can be set according to the demand of air conditioning load regulation business.
2.2.4 Environmental data collection: LON3112 communication management device can collect environmental temperature and humidity data from users' air conditioning system terminals (indoor) and outdoor environments, including environmental temperature and humidity sensors, smart sockets, etc.The collection interval should be set according to the demand of air conditioning load regulation business.


3.Hardware specifications
 

4.Software specifications

5.Product size
6.Solution

LON3112 communication management device is a device that can communicate with user side load measurement devices, sensors, air conditioning equipment, or modules or systems that manage and monitor air conditioning. It can achieve various data collection, data storage, data encryption, operation status monitoring, and dynamic control, and can exchange information with the new power load management system platform.

7.About our service          
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.


8.Package and ship
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA