24 Hours for Service
1 Year
Air Cooled & Water Cooled
City Water
Combined
Single-speed Fan
Low
Cold Room, Freezer
ISO, CCC
New
Axial&Centrifugal
Copper
Aluminium Alloy
Monoblock
Thermojinn
Wooden Frame
450x940x975
China
Product Description

A01W/ A01T series Monoblocks
A01W Wall straddle Monoblock & A01T Through wall Monoblock applies to various cold storages. The unit can be installed on the wall, and can be assembled with multi units stacked together.
Cases of the Monoblock are with Epoxy sprayed steel plates.
Hermetic piston compressors are applied, with R404A as the refrigerant.



STANDARD CONFIGURATION
○ Low noise Hermetic compressor
○ One time formulation casing for evaporator
○ Auto defrosting system
○ Condenser over-dirt alarm system
○ Condensate water evaporation tray
○ Expansion through capillary tube system
○ Filter on the liquid line
○ Cold room light and bulb
○ Cable for door micro switch
○ Cable for door switch heater on low temperature units
○ High- and low-pressure switches
○ Remote electronic control panel
OPTIONAL ACCESSARIES AND CONFIGURATION.
Power supply:
230/1~/50
400/3N~/50
208-230/1~/60
230/3~/50
208-230/3~/60
440-460/3N~/60
440-460/3~/60
108-115/1~/60
Electrical accessories:
Prearrangement for supervision system
Accessories kit:
Audible and visual alarm
Remote control panel for 2-3-4 units
Condensation type:
Air + Axial Fan
Air + Centrifugal fan
City water with pressure valve
Winter Kit, low ambient temperature accessories:
Crankcase heater + Condenser fan pressure switch +
Double solenoid valve for defrosting
Crankcase heater + Pressure controlled condenser fan
speed regulator + Double solenoid valve for defrosting
PRODUCT PARAMETERS
MEDIUM TEMPERATURE ARGUMENTS - A01W
Model | WMA010C2 | WMA015C2 | WMA018C2 | WMA025C2 |
Compressor (HP) | 1HP | 1.5HP | 1.8HP | 2.5HP |
Power supply | 220V/1P/50Hz | 220V/1P/50Hz | 380V/3P/50Hz | 380V/3P/50Hz |
Condenser Air flow rate (m3/h) | 630m3/h | 1260m3/h | 2670m3/h | 2670m3/h |
Evaporator air flow rate (m3/h) | 745m3/h | 1490m3/h | 2670m3/h | 2670m3/h |
Installation power (kw) | 0.995kw | 1.477kw | 1.662kw | 2.135kw |
LOW TEMPERATURE ARGUMENTS - A01W
Model | WLA010C2 | WLA015C2 | WLA020C2 | WLA030C2 | WLA040C2 |
Compressor (HP) | 1HP | 1.5HP | 2HP | 3HP | 4HP |
Power supply | 220V/1P/50Hz | 220V/1P/50Hz | 380v/3P/50hz | 380v/3P/50hz | 380v/3P/50hz |
Condenser Air flow rate (m3/h) | 630m3/h | 1260m3/h | 1260m3/h | 2670m3/h | 2670m3/h |
Evaporator air flow rate (m3/h) | 745m3/h | 1490m3/h | 1490m3/h | 2670m3/h | 2670m3/h |
Installation power (kw) | 0.86kw | 1.243kw | 1.538kw | 1.992kw | 2.539kw |
MEDIUM TEMPERATURE ARGUMENTS - A01T
Model | TMA035C2 | TMA045C2 | TMA055C2 | TMA065C2 |
Compressor (HP) | 3.5HP | 4.5HP | 5.5HP | 5HP |
Power supply | 380V/3P/50Hz | 380V/3P/50Hz | 380V/3P/50Hz | 380v/3p/50hz |
Condenser Air flow rate (m3/h) | 3600m3/h | 5400m3/h | 5400m3/h | 7200m3/h |
Evaporator air flow rate (m3/h) | 6000m3/h | 9000m3/h | 9000m3/h | 11181m3/h |
Installation power (kw) | 3.5kw | 4.8kw | 5.4kw | 6.9kw |
LOW TEMPERATURE ARGUMENTS - A01T
Model | TLA065C2 | TLA085C2 | TLA105C2 | TLA135C2 |
Compressor (HP) | 6.5HP | 1.5HP | 1.8HP | 2.5HP |
Power supply | 380V/3P/50Hz | 380V/3P/50Hz | 380V/3P/50Hz | 380V/3P/50Hz |
Condenser Air flow rate (m3/h) | 3600m3/h | 5400m3/h | 5400m3/h | 7200m3/h |
Evaporator air flow rate (m3/h) | 6000m3/h | 9000m3/h | 9000m3/h | 11181m3/h |
Installation power (kw) | 6.4kw | 7.6kw | 9.3kw | 12.1kw |



○ The installation of the A01W and A01T series mono block is installed on the wall.
○ The evaporator part is designed to be placed on the wall or through the wall.
○ The condensing part lays outside the cold room.
○ The unit must be positioned in an environment with good air circulation, away from high heat sources and away from obstacles that could limit the possibility of good suction and equally good discharge of the treated air.
APPLICATION



FAQ:
1: How long is the delivery time?