Product Description
Removable element woltman cold (hot) water meter
Application:
--Measuring the total volume of cold(hot) water passing through the pipeline.
-NOTE:This type of water meter can be used for a reading transmission system as equipped with pluse.
Feature:
-- Dry-dial, Magnetic drive
----Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
--Removable element unit and strong universality, easy installation and maintenance,
--Measuing high flow rate with low head loss.
-- Remote transmission device can be added upon request,such as Reed Switch or Hall, Pulse Output:100000L/P,10000L/P.
--Technical data conform to international standard ISO 4064.
Working condition
Water temperature: T30 T50 T90
Water pressure class: MAP16 MAP10
Pressure-loss Class: △p63
Accuracy:
(1) From minimum flow-rate(Q1) inclusive to transitional flow-rate(Q2) exclusive±5%.
(2) From transitional flow-rate(Q2) to overload flow-rate(Q4):±2%;
(Hot water meter ±3%)
NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.








Application:
--Measuring the total volume of cold(hot) water passing through the pipeline.
-NOTE:This type of water meter can be used for a reading transmission system as equipped with pluse.
Feature:
-- Dry-dial, Magnetic drive
----Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
--Removable element unit and strong universality, easy installation and maintenance,
--Measuing high flow rate with low head loss.
-- Remote transmission device can be added upon request,such as Reed Switch or Hall, Pulse Output:100000L/P,10000L/P.
--Technical data conform to international standard ISO 4064.
Working condition
Water temperature: T30 T50 T90
Water pressure class: MAP16 MAP10
Pressure-loss Class: △p63
Accuracy:
(1) From minimum flow-rate(Q1) inclusive to transitional flow-rate(Q2) exclusive±5%.
(2) From transitional flow-rate(Q2) to overload flow-rate(Q4):±2%;
(Hot water meter ±3%)
MAIN TECHNICAL SPECIFICATIONS
Type | Size | Class | Q4 Overload Flow | Q3 Permanent Flow | Q2 Transitional Flow | Q1 Min.Flow | Min. Reading | Max. Reading | ||
m3/h | m3 | |||||||||
LXLC-350 | 14 | R50 | 1750 | 1400 | 44.8 | 28 | 0.02 | 999,999,999 | ||
LXLC-400 | 16 | 2000 | 1600 | 51.2 | 32 | 0.02 | 999,999,999 | |||
LXLC-450 | 18 | 2000 | 1600 | 51.2 | 32 | 0.02 | 999,999,999 | |||
LXLC-500 | 20 | 3125 | 2500 | 80 | 50 | 0.02 | 999,999,999 | |||
LXLC-600 | 24 | 5000 | 4000 | 128 | 80 | 0.02 | 999,999,999 |
DIMENSIONS
Type | Size | Length | Height | Connecting flange | |||||
φD1 Outside diameter | φD2 Bolt circle diameter | Connecting Bolts(n-M) | Working pressure (MPa) | ||||||
mm | |||||||||
LXLC-350 | 14 | 500 | 590 | 505 | 460 | 16-M20 | 1.0 | ||
520 | 470 | 16-M24 | 1.6 | ||||||
LXLC-400 | 16 | 600 | 660 | 565 | 515 | 16-M24 | 1.0 | ||
580 | 525 | 16-M27 | 1.6 | ||||||
LXLC-450 | 18 | 600 | 700 | 615 | 565 | 20-M24 | 1.0 | ||
640 | 585 | 20-M27 | 1.6 | ||||||
LXLC-500 | 20 | 800 | 760 | 670 | 620 | 20-M24 | 1.0 | ||
715 | 650 | 20-M30 | 1.6 | ||||||
LXLC-600 | 24 | 800 | 880 | 780 | 725 | 20-M27 | 1.0 | ||
840 | 770 | 20-M33 | 1.6 |