Roof Mounted Monoblock Refrigeration Unit/Uniblock Cold Room Refrigeration Unit/ Mini Condensing Unit and Evaporator in One.

Price $1500.00 Compare
Min Order 1 Piece
Shipping From Fujian, China
Popularity 290 people viewed
Quantity
+-
 

FUZHOU THERMOJINN REFTECH CO., LTD.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
1 Year
Air Cooled & Water Cooled
24hr Services
Axial&Centrifugal
Copper
Aluminium Alloy
Monoblock
Combined
Single-Speed Fan
Low
ISO, CCC
New
City Water
Cold Room, Freezer
Thermojinn
Wooden Frame
450x940x975
China
Product Description
 
 

 

A01R series Monoblock
 

A01R series Monoblock applies to cold storages with space available on the top.Cases of the Monoblock are with Epoxy sprayed steel plates. And conjunction partof evaporator and condenser unit is using insulated heat-rejected boxes. Hermeticpiston compressors are applied, with R404A as the refrigerant.


STANDARD CONFIGURATION
○  Low noise Hermetic compressor
○  One time formulation casing for evaporator
○  Auto defrosting system
○  Condenser over-dirt alarm system
○  Condensate water evaporation tray
○  Expansion through capillary tube
○  Filter on the liquid line
○  Cold room light and bulb
○  Cable for door micro switch
○  Cable for door switch heater on low temperature units
○  High- and low-pressure switches
○  Remote electronic control panel

OPTIONAL ACCESSARIES AND CONFIGURATION.

Power supply:
230/1~/50
400/3N~/50
208-230/1~/60
230/3~/50
208-230/3~/60
440-460/3N~/60
440-460/3~/60
108-115/1~/60

Electrical accessories:
Prearrangement for supervision system

Accessories kit:
Audible and visual alarm
Remote control panel for 2-3-4 units

Condensation type:
Air + Axial Fan
Air + Centrifugal fan
City water with pressure valve

Winter Kit, low ambient temperature accessories:
Crankcase heater + Condenser fan pressure switch +
Double solenoid valve for defrosting
Crankcase heater + Pressure controlled condenser fan
speed regulator + Double solenoid valve for defrosting

Product Parameters


PRODUCT PARAMETERS

MEDIUM TEMPERATURE UNITS - AIR COOLED TYPE
Model

RMA012C2

RMA015C2

RMA018C2

RMA025C2

RMA027C2

RMA030C2

RMA035C2
Compressor (HP)1.2HP1.5HP1.8HP2.5HP2.7HP2.7HP3.5HP

Power supply

220v/1p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz
Condenser Air flow rate (m3/h)1690m3/h1690m3/h2300m3/h2300m3/h3700m3/h3700m3/h3700m3/h
Evaporator air flow rate (m3/h)1490m3/h1490m3/h3700m3/h3700m3/h3700m3/h5500m3/h5500m3/h
Installation power (kw)1.22kw1.395kw1.849kw2.329kw2.58kw2.7kw3.49kw

MEDIUM TEMPERATURE UNITS - WATER COOLED TYPE

Model

RMW012C2

RMW015C2

RMW018C2

RMW025C2

RMW027C2

RMW030C2

RMW035C2
Compressor (HP)1.2HP1.5HP1.8HP2.5HP2.7HP2.7HP3.5HP

Power supply

220v/1p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz
Condenser Air flow rate (m3/h)1690m3/h1690m3/h2300m3/h2300m3/h3700m3/h3700m3/h3700m3/h
Evaporator air flow rate (m3/h)1490m3/h1490m3/h3700m3/h3700m3/h3700m3/h5500m3/h5500m3/h
Installation power (kw)1.135kw1.31kw1.72kw2.2kw2.4kw2.52kw3.3149kw

LOW TEMPERATURE UNITS - AIR COOLED TYPE

Model

RLA020C2

RLA027C2

RLA040C2

RLA050C2

RLA060C2
Compressor (HP)2HP2.7HP4HP5HP6HP

Power supply

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz

380v/3p/50hz
Condenser Air flow rate (m3/h)1690m3/h2300m3/h3700m3/h3700m3/h3700m3/h
Evaporator air flow rate (m3/h)1490m3/h3700m3/h3700m3/h5550m3/h5550m3/h
Installation power (kw)1.581kw2.095kw2.579kw3.101kw4.078kw

LOW TEMPERATURE UNITS - WATER COOLED TYPE

Model

RLW020C2

RLW027C2

RLW040C2

RLW050C2

RLW060C2
Compressor (HP)1.2HP1.5HP1.8HP2.5HP2.7HP

Power supply

400v/3p/50hz

400v/3p/50hz

400v/3p/50hz

400v/3p/50hz

400v/3p/50hz
Condenser Air flow rate (m3/h)1690m3/h2300m3/h3700m3/h3700m3/h3700m3/h
Evaporator air flow rate (m3/h)1490m3/h3700m3/h3700m3/h5550m3/h5550m3/h
Installation power (kw)1.469kw1.966kw2.399kw2.921kw3.898kw
The installation of the A01Rseries mono block is on the roof of the cold room. The body ofthe evaporator part is designed to be placed in the hole created in the roof of the cold room.The condensing part lays on the top ofthe cold room.
The unit must be positioned in an environment with good air circulation, away from highheat sources and away from obstacles that could limit the possibility of good suction andequally good discharge ofthe treated air.

APPLICATION


COMPANY EXHIBITION

PACKING & TRANSPORT

FAQ:

1: How long is the delivery time? 
It takes within 1 month from receipt of the deposit to preparation of the goods.

2: How long is the quality guarantee period?
The warranty period is 1 year, and the after-sales service is available 24 hours.

3: What is your price?
Our FOB price is based on quantity, material and size you required.The more machines you order, the lower price we will give! Also CIF CNF price is the same.
4: What can you do for us?
All material/ size are available, also we can customize products as your requirements. Any questions, pls don't hesitate to contact us.


Message Type
* Message Content
* Name  
* Phone
* Email