RSD6000
Biological Diagnostics
Patient Monitor
CE, MSDS, ISO13485
Adult,Neo,PED
NIBP,SpO2,Temp,ECG,Hr
Ronseda
Carton Box
8inch
China
Product Description
RSD6000 Hospital Diagnostic Machine Patient Monitor ECG SPO2 NIBP TEMP PR RESP 6Parameters Features: Standard configuration:SPO2,ECG,NIBP,TEMP,RESP 8inch high brightness, high resolution color TFT LED display Waterproof , fanless design, low energy consumption Built-in rechargeable Li-battery working up-to 5 hours for field monitoring, ambulance and short term transportation Clear bright and Large character display , NIBP measurement review, one-click operation, unique Vector display 7 channel ECG waveform display;ST-segment analysis Application:Adult,pediatric,neonate; working mode: diagnosis,monitor and surgery 13 kinds of arrhythmia analysis and 15 kinds of drug dose calculation High-frequency electric surgical knives(300W),defibrillation and ESU protection New SpO2 technology to ensure the accuracy and low perfusion upto 0.2% measurement Intelligent audio and visual alarm function Optional parts:HDMI ;EtCO2;touch screen ![]() Specifications: ECG ECG Cable: Standard 3/ 5 leads 3 Leads:RA,LA,LL,Leads section:I,II,III 5 Leads:RA,LA,LL,RL,V, Leads section:I,II,III/aVR,aVL,aVF/V Gain selection:´0.25,´0.5,´1,´2 Heart Rate Range: Adult:15 ~ 300bpm Children/Infant/Neonate:15 ~ 350 bpm Accuracy:±1% or ±1bpm Resolution:1 bpm Sensitivity >200 uV(Peak to peak) Input Resistance >5(MΩ) Bandwidth: Diagnosis :0.05~130Hz Monitor:0.5~40Hz Surgery :1~20Hz ST segment deviation analysis: Range:-0.8 mV~+0.8mV Accuracy:±2.0mV NIBP: Work mode: Manual, Automatic, Continuous Unit: mmHg, Kpa Measurement Range: Adult: SYS: 40~270mmHg DIA: 10~215mmHg MEAN:20~240mmHg Pediatric: SYS:40~200mmHg DIA: 10~150mmHg MEAN:20~165mmHg Neonatal:SYS:40~135mmHg DIA:10~100mmHg MEAN:20~110mmHg Resolution:1mmHg Measurement Type :SYS,DIA,MEAN Overpressure protection Adult: 300mmHg Pediatric :240mmHg Infant/Neonate :150mmHg SpO2 Measurement range:0~100% Resolution:1% Accuracy:±2(70~100%) Pulse rate Measurment range:20~300bpm Resolution:1bpm Accuracy:±3bpm Respiration: Measurement Range: Adult: 2~120BrPM Child/Infant/Neonate:2~150 BrPM Resolution:1 BrPM Accuracy:±2 BrPM Asphyxiation alarm: 10~40 seconds Resolution:1BrPM Accuracy:±2% TEMP: Channel Number: 2 Measurement Range: 0~50°C Resolution : 0.1°C Accuracy:±0.1°C Response time: ≤ 3min Power requirement Voltage:90~245V AC 50/60Hz Power Consumption:15W Battery:14.8V 2200mAH Li- Battery Battery life: 5 hours DC: 12~20V/2A Working Environment: Operating Temperature:0 ~ 40 (°C) Transport and Storage Temperature:-20~60 (°C) Working Humidity ≤ 85 % Transport and Storage Humidity: ≤ 93 % ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
