S-800-65
Single
3 Years
800W
100-250VAC
Series Switching Power Supply
Separate-excited Switching Power Supply
Width Modulation Type
Terminal Power Distribution Equipment
One-way Transmission
PWM
CE, RoHS, ISO, CCC, Bis
Nvvv
Short Circuit Overload Overvolt Overtemp
12.3A
Switching DC Power
86%
100%Factory
65V
LED, CCTV and So on
47-63Hz
NVVV
Safety Packing
250*125*65mm
China
Product Description



S-800 800W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 66.5A | 33.3A | 22.2A | 16.6A | |
Rated power | 798W | 799.2W | 799.2W | 796.8 | |
Ripple and noise | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | <±1.2% | <±1% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±1% | ||||
Input | Voltage range | 90-132/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
Efficiency (typical) | >82% | >84% | >86% | >86% | |
Working current | <12A 115VAC <7.8A 230VAC | ||||
Impulse current | 110VAC: 25A 220VAC: 50A | ||||
Start, rise, hold time | 200ms,50ms,20ms :230VAC | ||||
Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Overvoltage protection | Close output when ≥ 115% - 145% | ||||
Short circuit protection | Close output | ||||
Over temperature protection | Rth3: ≥ 70 ºC fast rotation of fan, ≥ 90 ºC close output | ||||
Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
Storage temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output < 6mA at 1.5kVac | ||||
Leakage current | Input output at 220VAC < 1mA | ||||
Isolation resistance | Input output, input shell, output shell: 500VDC / 100M Ω | ||||
Other | size | 241*125*65mm | |||
Net weight / gross weight | 1268/1358g | ||||
Remarks | Ripple and noise measurement method: use a 12 "twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ºC. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% - 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ºC / 1000m |






Q1:How many Voltage you can supply? A: 12v,24v,48v,50v,60v,110v(Depend on items).
Q2Can I have a sample order? A: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable. At the same time, we have overseas warehouses so that you can get the products faster.
Q3Do you have any MOQ limited for the order? A: Low MOQ, 1pc for sample checking is available.
Q4How do you ship the goods and how long does it take to arrive? A: We usually ship by DHL, UPS, FedEx, or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping is also optional.
Q5Do you offer a guarantee for the products? A: Yes, we offer a warranty on our products.
Q6: How to deal with the faulty? A: Firstly, our products are produced in a strict quality control system and the defective rate will be less. Secondly, during the guarantee period, we will send new products with new orders for small quantities.
For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to the real situation.