HMD2004RTN
Resistance Strain Gauge Pressure Sensors
Mechanical Structure Type
Strain Gauge Pressure Transmitter
Analog Type
Integration
Stainless Steel
G
Four-Wire
Steel
IP67
ISO
Customized
Schenck Load Cell Rtn 200t C3
HMD
Wooden Box
different size
China
Product Description
Description:
HMD2004RTN RING TORSION LOAD CELLS: PRECISE WEIGHING UP TO 470 TONS
Different HMD2004RTN ring torsion load cell versions are available for a wide range of maximum capacities (up to 470 tons) and feature very low height. They are well-suited for any type of container weighing task as well as for large platform scales. Typical applications include the construction of truck scales. Unlike other load cells of this type, HMD2004RTN load cells - due to the use of unique ring-shaped strain gauges - significantly minimize the effects of transverse and lateral loads.
Key Features:
Maximum capacity: 1 t to 470 t
High precision and high signal-to-noise ratio, due to the 2.85 mV/V output signal
Wide temperature range from -30 °C to +80 °C (optionally up to +110 °C)
Resistance to chemicals
Large cable cross-section for low temperature influence
Very low height
Different cable lengths and cable types available
Also available as a complete weighing module, for easy mechanical integratio
Drawing:

HMD2004RTN RING TORSION LOAD CELLS: PRECISE WEIGHING UP TO 470 TONS
Different HMD2004RTN ring torsion load cell versions are available for a wide range of maximum capacities (up to 470 tons) and feature very low height. They are well-suited for any type of container weighing task as well as for large platform scales. Typical applications include the construction of truck scales. Unlike other load cells of this type, HMD2004RTN load cells - due to the use of unique ring-shaped strain gauges - significantly minimize the effects of transverse and lateral loads.
Key Features:
Maximum capacity: 1 t to 470 t
High precision and high signal-to-noise ratio, due to the 2.85 mV/V output signal
Wide temperature range from -30 °C to +80 °C (optionally up to +110 °C)
Resistance to chemicals
Large cable cross-section for low temperature influence
Very low height
Different cable lengths and cable types available
Also available as a complete weighing module, for easy mechanical integratio
Drawing:

Capacity(kg) | 1 | 2.2 | 4.7 | 10 | 15 | 22 | 33 | 47 | 68 | 100 | 150 | 220 | 330 | 470 |
D | ∅60 | ∅60 | ∅60 | ∅75 | ∅75 | ∅75 | ∅95 | ∅130 | ∅130 | ∅150 | ∅150 | ∅225 | ∅225 | ∅270 |
D1 | ∅54 | ∅54 | ∅54 | ∅75 | ∅75 | ∅75 | ∅95 | ∅130 | ∅130 | ∅150 | ∅150 | ∅225 | ∅225 | ∅270 |
D2 | ∅20 | ∅20 | ∅20 | ∅30 | ∅30 | ∅30 | ∅40 | ∅60 | ∅60 | ∅70 | ∅70 | ∅100 | ∅100 | ∅120 |
D3 | ∅53 | ∅53 | ∅53 | |||||||||||
H1 | 7.5 | 7.5 | 7.5 | 6.5 | 6.5 | 6.5 | 10 | 14 | 14 | 16 | 16 | 24 | 24 | 28 |
H2 | 43 | 43 | 43 | 50 | 50 | 50 | 65 | 75 | 85 | 90 | 100 | 130 | 145 | 170 |
H3 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 10 | 10 | 10 |
MODEL | HMD2004RTN | |||||||
COMPREHENSIVE ERROR | 0.02 0.03 0.05 | |||||||
OUTPUT SENSITIVITY mV/V | 2.85±0.25% | |||||||
NONLINEARITY %F.S | ± 0.02 ± 0.03 ± 0.05 | |||||||
REPEATABILITY %F.S | 0.02 0.02 0.03 | |||||||
HYSTERESIS %F.S | ± 0.02 ± 0.03 ± 0.05 | |||||||
CREEP (30min)%F.S | ± 0.02 ± 0.03 ± 0.05 | |||||||
TEMP.EFFECT ON ZERO %F.S/10ºC | ≤0.002 ≤0.003 ≤0.005 | |||||||
TEMP.EFFECT ON OUTPUT %F.S/10ºC | ≤0.002 ≤0.003 ≤0.005 | |||||||
ZERO OUTPUT %F.S. | ±1 ±1 ±2 | |||||||
INPUT RESISTANCE Ω | 4480±50 | |||||||
OUTPUT RESISTANCE Ω | 4010±10 | |||||||
INSULATION RESISTANCE MΩ | ≥5000 ≥2000 | |||||||
EXCITATION VOLTAGE V(DC/AC) | 5~12V | |||||||
OPERATION TEMP.RANGE ºC | -10~+80 | |||||||
OVERLOAD CAPACITY %F.S. | 150 | |||||||
CAPACITY | 1~470t | |||||||
DEGREE OF PROTECTION | IP67 |