PCT-621A
18mths
18mths
ISO 9001:2008
Electric
Vacuum
Natural Gas, Crude Oil
Plug-In
Alloy
Truck Mounted
Plunger Pump
50days
Wooden Box
SERVA
Export Standard
standard
China
841343100
Product Description
1. Overview
PCT-621A double pump cementing truck adopts TPB600 pump with the features of compact structure and light weight, with standard configuration of VOLVO FM440 6X6 chassis.
SERVA TPB600 pump has prominent features of smaller volume and lighter weight. With two pump back to back installation, the overall width will only be 2580mm which can extremely decrease the overall dimension (weight) of unit, especially applicable to truck-mounted units or offshore equipments.
2.General specification
Max. working pressure:
Max. pressure: 69 MPa(w/ 3 1/2" fluid end)
Max. pressure 97.5 MPa (w/ 3" fluid end)
Max. flow: 3.0 m3/min(w/one 3" and one 4 1/2" Fluid End)
3.4 m3/min(w/two 3 1/2" and one 4 1/2"Fluid Ends)
Density range: 1.3-2.5g/cm3
Auto control precision: ±0.02 g/cm3
Mixing capacity: 0.3-2.3m3/min
Working ambient temperature: -20°C - 50°C
Overall dimension (mm): 11450(L) x 2600(W) x 4200 (H)
Net weight: 30000kg

3. Features 


PCT-621A double pump cementing truck adopts TPB600 pump with the features of compact structure and light weight, with standard configuration of VOLVO FM440 6X6 chassis.
SERVA TPB600 pump has prominent features of smaller volume and lighter weight. With two pump back to back installation, the overall width will only be 2580mm which can extremely decrease the overall dimension (weight) of unit, especially applicable to truck-mounted units or offshore equipments.
2.General specification
Max. working pressure:
Max. pressure: 69 MPa(w/ 3 1/2" fluid end)
Max. pressure 97.5 MPa (w/ 3" fluid end)
Max. flow: 3.0 m3/min(w/one 3" and one 4 1/2" Fluid End)
3.4 m3/min(w/two 3 1/2" and one 4 1/2"Fluid Ends)
Density range: 1.3-2.5g/cm3
Auto control precision: ±0.02 g/cm3
Mixing capacity: 0.3-2.3m3/min
Working ambient temperature: -20°C - 50°C
Overall dimension (mm): 11450(L) x 2600(W) x 4200 (H)
Net weight: 30000kg
Technical Specification | ||||
Chassis | Volvo FM440 6x6 | |||
Engine | C13 475HP @ 2100 RPM (2 sets) | |||
C15 540HP @ 2100 RPM (optional) | ||||
Detroit S60 475HP @ 2100 RPM (optional) | ||||
Transmission | Allision 4700OFS (5 forward gears + netural gear) (2 sets) | |||
Hydraulic system | Driven by chassis and deck transmission PTO, closed loop for C-pumps, open loop for agitators | |||
Triplex pump (2 sets) | ||||
Model/type | SERVA TPB600 reciprocal, horizontal single plunger pump | |||
Stroke | 6" (152.4mm) | |||
Max. B.H.P. | 600 BHP (447Kw) | |||
Gear ratio | 4.6:1 | |||
Fluid end | 3" | 3 1/2" | 4" | 4 1/2" |
Rated pressure | 14,140PSI (97.5Mpa) | 10,000PSI(69Mpa) | 7,958PSI (56.1Mpa) | 6,290PSI (43.4Mpa) |
Max. Discharge rate | 0.95M3/min | 1.27m3/min | 1.67M3/min | 2.13M3/min |
ACM-III. 1 Mixing system | ||||
Mixer | High energy recirculating jet mixer | |||
Dry cement valve | Off-center bulk cement metering valve | |||
Mixing water pump | SERVA 4x3 (1.5m3/min @0.78Mpa) | |||
Slurry reciculating/booster pump | SERVA RA56 (3.7m3/min @0.45Mpa) (two sets) | |||
Densitometer | Micro motion 3" F300 non-radioactive densitometer | |||
Computer system | AB PLC | |||
Others | ||||
Mixing tank | 8 BBL (1.4m3) | fuel tank | 400+300 L | |
Average tank | 20 BBL (2x1.5m3) | hydraulic oil tank | 170L | |
Measuring tank | 2x10 BBL (2x1.5m3) | air tank | 80L |

3. Features
- 1m3 surge tank avalible, utilized to make bulk cement delivery more stable so as to improve the accuracy of auto control system and slurry quality.
- The mixing power is partially supplied by chassis which increases the actual operation power of main engine.
- High energy recirculating jet mixing system.
- Off-center dry cement valve avoids bulk cement from choking.
- Emergency kill system of air inlet shutoff.
- SPS non-leakage packing system.
- Plunger pump overpressure protection system.
- F300 Non-radioactive densitometer is easy to wash, safe and reliable.
- Simplify operation, adapts to working habits in oilfield.
- 10" operation screen, convenient to monitor the working data.
- Portable wireless/ wired data acquisition system.
- Diesel fired coolant pre-heat system available. The heater allows the engine to be preheated before starting without the use of external power.