DEFINITION:
Set of moving device that fitted into a closed conduit driven directly by water flow. Its turbine rotor rotates about the axis which is perpendicular to water flow.
WORKING PRINCIPLES:
Water flow drives vane rotate. Rotating times which is proportional to water flow speed are gathered, hence total volume passed through water meter is recorded.
CHARACTERS:
Types: Wet, dry, vertical, liquid sealed.
Wide measuring range, high accuracy.
Stable measuring capacity
Long working life
Low pressure loss
All technical figures are conformed with GB/T778. 1~3-1996 which is equivalent to ISO4064 Standard Class B.
WORKING CONDITION:
Water temperature≤45ºC(Hot water meter≤90ºC)
Water pressure≤1Mpa
MAXIMUM PERMISSIBLE ERROR:
From the minimum flow-rate (qmin) inclusive to the lower zone of the transitionalflow-rate (qt) exclusive: ±5%.
From the transitional flow-rate (qt) inclusive to the higher zone of the maximum flow-rate (qmax) exclusive: ±2%(hot water meter±3%. )
Overall dimensions and weight
Set of moving device that fitted into a closed conduit driven directly by water flow. Its turbine rotor rotates about the axis which is perpendicular to water flow.
WORKING PRINCIPLES:
Water flow drives vane rotate. Rotating times which is proportional to water flow speed are gathered, hence total volume passed through water meter is recorded.
CHARACTERS:
Types: Wet, dry, vertical, liquid sealed.
Wide measuring range, high accuracy.
Stable measuring capacity
Long working life
Low pressure loss
All technical figures are conformed with GB/T778. 1~3-1996 which is equivalent to ISO4064 Standard Class B.
WORKING CONDITION:
Water temperature≤45ºC(Hot water meter≤90ºC)
Water pressure≤1Mpa
MAXIMUM PERMISSIBLE ERROR:
From the minimum flow-rate (qmin) inclusive to the lower zone of the transitionalflow-rate (qt) exclusive: ±5%.
From the transitional flow-rate (qt) inclusive to the higher zone of the maximum flow-rate (qmax) exclusive: ±2%(hot water meter±3%. )
DN/Q | Q4=1.25Q3 | Q3 | R=Q3/Q1 | Q2=1.6Q1 | Q1 | R=Q3/Q1 | Q2=1.6Q1 | Q1 |
l/h | l/h | l/h | ||||||
15 | 3125 | 2500 | 80 | 50 | 31.25 | 100 | 40 | 25 |
20 | 5000 | 4000 | 80 | 80 | 50 | 100 | 64 | 40 |
Nominal size DN (mm) | Class of measurement | Overload flow-rate q s (m 3 /h) | Permanent flow-rate q p (m 3 /h) | Transitional flow-rate q t (l/h) | Minimum flow-rate q min (l/h) |
15 | B | 3 | 1.5 | 120 | 30 |
20 | B | 3 | 1.5 | 200 | 50 |
Overall dimensions and weight
Type | Size (mm) | Length (mm) L | Width (mm) W | Height (mm) H | Connecting Thread D | Weight(kg) |
LXSG(R)-13D4 | 15 | 110/115 | 77 | 80 | G 3/4"B | 0.78 |
LXSG(R)-20D4 | 20 | 110/115/130 | 80 | 80 | G 1"B | 0.98 |