Single Phase 66-330kv Oil Immersed Dead Tank Current Transformer with Transient Protection

Price $9999.00 Compare
Min Order 1 Piece
Shipping From Henan, China
Popularity 457 people viewed
Quantity
+-
 

Henan Energy Electric Equipment Co.,Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
LBT
Electronic, Instrument, Position Sensor, Audio, Lighting
Current Transformer
Single
Outdoor
Protection, Measurement
Single Layer & Tightly Wound Type
Insulating Paper
Strut Type
Cascade Type
Electromagnetic Type
66kv-330kv
Acceptable
Chinese, English, Russian
Negotiable
Fob, CIF, EXW, DAP,CIP
It Depends
HEZC
Cartons or Others
As required
China
Product Description
Company Profile

Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.

Product Description
It is outdoor,single phase and oil immersed dead tank type current transformer, which is used for metering and relay protection of 66-330kV,50 or 60Hz system.

Standards:
IEC 61869-1;IEC 61869-2
GB 20840.1; GB 20840.2


 
Product Features

1.It is oil paper insulation structure.The main insulation is wound from high voltage cable paper, and is placed several capacitor screen of voltage division in the primary insulation, which can improve electric field distributing and decrease the consumption of insulation material. It will be immersed with transformer oil after desiccating under vacuum. It has advantages of stable and reliable performance of insulation, rich operated experience, long service life.
2. Perfect fluidity performance of transformer oil is good for heat dissipation,it also has self recover ability for the failure of partial discharge  caused by air bubble and dust.
3. The current ratio can be changed easily by switching the connection method of Primary winding to series or parallel.
4. Hermetically sealed stainless steel metallic bellows is installed on the top,which protect the transformer oil from moisture and extend the life time, also there is a oil level gauge on the bellows for observing the change of oil volume.
5. There is a multi function oil drainvalve onthe base,which make it more convenient for sampling,draining.
6. All adopted insulation parts are environmental protection materials.
7. Secondary terminal board is made of epoxy casting,the sealing performance is more reliable.
8. The base uses spray painting or hot galvanizing,which gives a high degree of corrosion resistance.
9. Fasteners and name plate are stainless steel.

Product Parameters
 
Rated voltage,kV66 or 69110 or 115132 or 13850220 or 230330
IIighest voltage for equipment,kV72.5123 or 126145170245 or 252363
Rated frequency,Hz50 or 60
Rated power frequency withstand voltage,kV140/160230275325460510
Rated lightning impulse voltage,kV325/35055065075010501175
Flashover distance,mm70011001300150021002350
Cree.distance,mmW1:1450 
W2:1820 
W3:2250
W1:2520 
W2:3150 
W3:3910
W1:2900 
W2:3630 
W3:4500
W1:3400 
W2:4250 
W3:5270
W1:5040 
W2:6300 
W3:7820
W1:7260 
W2:9075 
W3:11253
Mechanical load,N300030004000400040004000
Rated primary current,A2500-4000
Rated secondary current,A1; 2; 5
Accuracy class0.1; 0.2; 0.5; 0.2S; 0.5S; 5P; 10P; PX:
Ratedoutput(recommended value),VA1A10-15VA 
2A: 10~15VA 
5A: 15~50VA
Instrument security factor FS5;10
Accuracy limit factors ALF10;15; 20; 25; 30; 40
Short-time thermal current(Mas   n),kA50kA/3s
Technical data of transient protection winding
Accuracy classTPY
Rated ratio, A2500-4000/1
Rated resistive burden(Rb), VA7.5;10;15; 20
Rated symmetrical short-circuit current times (Kssc)10;15; 20
Rated primary time constant (Tp)40; 60; 80;100
Duty cycle:C-0.1s-O 
C-0.1(0.04)s-O
C-0.1(0.04)s-0.5s-0.1(0.04)s-O
Structure Diagram
                                                                                                                                                                    
Service Environment

1. Ambient  temperature:-50ºC- +45ºC
2. Altitude:≤2000m(If above 2000m,the product will be customized according to user's request)
3. Pollution level: II, III, IV.

Packaging & Shipping
Certifications












 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA