PTC-8125M (ANSI 1S-4S)
Yes
12 Month
2400mm
<900kg
Universal Testing Machine
100A(200A Max) Adjustment Range: 0 ~ 120%
0.05 / 0.1
Electronic Load
Static Load
Digital
Computer Control and Manual Control
100-500Kg
120V(240V) Adjustment Range: 0 ~ 120%
Under
0.05 / 0.1
Hc3101A 0.05 /0.1,Hc3101h 0.02
45Hz~65Hz
24 (12/24/48/60) on Requested
Hanpu
Standard Wooden Case
Accuracy class: 0.05 / 0.1
Zhejiang Jiaxing
9030849000
Product Description

1.1 With specialized ANSI meter, the worker needn't insert and extract,and the bench is suitable for FORM-1S,2S,3S,4S meter.
1.2 The energy meter hanging rack is made by Aluminum compound. The test bench can be installed scanning head. It is also can be accepted the signal for digital LED energy meter.
1.3 The bench uses PC to operate, The bench can automatically do starting test, no-load test(creep test), error test(accuracy test), deviation test, 24h variation test and so on. Test items and condition are flexible, and we can define the test scheme or use the standard test scheme. The test result can store in the data library. The bench can connect to the guest's net and upload the data.
1.2 The energy meter hanging rack is made by Aluminum compound. The test bench can be installed scanning head. It is also can be accepted the signal for digital LED energy meter.
1.3 The bench uses PC to operate, The bench can automatically do starting test, no-load test(creep test), error test(accuracy test), deviation test, 24h variation test and so on. Test items and condition are flexible, and we can define the test scheme or use the standard test scheme. The test result can store in the data library. The bench can connect to the guest's net and upload the data.
ITEMS | PTC-8125M | PTC-8125E | PTC-8125H | PTC-8320D | PTC-8320E | PTC-8320H | PTC-7100 | |
Basic functions | Basic error | ○ | ○ | ○ | ○ | ○ | ○ | × |
Creeping test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Starting test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Standard deviation | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Constant test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Meter constant | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Influence test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
No load test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Max demand test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Repeat test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
Multi-functions test | Day time error | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × |
L/N switching | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
Communication test | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
Power consumption test | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
High voltage | × | × | × | × | × | × | ○ |