SP116 SP118
>200L
Separate Type
Pressurized
Stainless Steel
Glass Vacuum Tube
Tank Insulation
CE, ISO9001, CCC
58*1800
25
Imposol
8 Years
Export
Imposol
standard exporting package
ISO, CE, SGS certificate
China
8419191000
Product Description
Solar system/solar water heater/separated solar water heater
Single pipeline working station solar system water heater SP116 SP118
Technical data
SP 116
1. Externality size: 450mm*310mm*150mm
2. Max. Self consumption: ≤ 3W
4. Range of temperature measuring: 0~150
5. Power of controlled pumps (temperature difference circulation pump, water-using end circulation pump): 600W
6. Electronic booster power: ≤ 3000W
7. System working pressure 8 bar and safety valve response pressure 6 bar.
8. Input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank)
9. Output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pump)
SP 118
1. Externality size: 450mm*310mm*150mm
2. Max. Self consumption: ≤ 3W
4. Range of temperature measuring: 0~150
5. Power of controlled pumps(temperature difference circulation pump, water-using end circulation pump) or electromagnetic valve: 600W
6. Electronical booster power: ≤ 3000W
7. Input signal: 6 temperature sensors (PT1000 for heat collector, NTC 10k B=3950 for water tank)
8. Output signal: 5 (electronic booster, 4 pumps or 3 pumps and 1 three way electromagnetic valve)
9. System working pressure 8 bar and safety valve response pressure 6 bar.
Installation
Vertically installed, installed at return trip between collector and water tank. As above picture.
Advantage
A. Designed for self-sustaining solar operation
B. Easy installation, save cost, beautiful appearance
C. Easy to check the flux of pipeline, temperature display.






Single pipeline working station solar system water heater SP116 SP118
Technical data
SP 116
1. Externality size: 450mm*310mm*150mm
2. Max. Self consumption: ≤ 3W
4. Range of temperature measuring: 0~150
5. Power of controlled pumps (temperature difference circulation pump, water-using end circulation pump): 600W
6. Electronic booster power: ≤ 3000W
7. System working pressure 8 bar and safety valve response pressure 6 bar.
8. Input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank)
9. Output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pump)
SP 118
1. Externality size: 450mm*310mm*150mm
2. Max. Self consumption: ≤ 3W
4. Range of temperature measuring: 0~150
5. Power of controlled pumps(temperature difference circulation pump, water-using end circulation pump) or electromagnetic valve: 600W
6. Electronical booster power: ≤ 3000W
7. Input signal: 6 temperature sensors (PT1000 for heat collector, NTC 10k B=3950 for water tank)
8. Output signal: 5 (electronic booster, 4 pumps or 3 pumps and 1 three way electromagnetic valve)
9. System working pressure 8 bar and safety valve response pressure 6 bar.
Installation
Vertically installed, installed at return trip between collector and water tank. As above picture.
Advantage
A. Designed for self-sustaining solar operation
B. Easy installation, save cost, beautiful appearance
C. Easy to check the flux of pipeline, temperature display.


Model | Capacity | Heat Pipe vacuum tube solar collector | Pump station | Expansion tank | Connection fittings | Loading quantity | ||
Model | Quantity | 20GP | 40HQ | |||||
IPSV100-NC/SC | 101L | IPRB A 581810 | 1 | SR881/882 SR961/962 SR971/972 SR981/982 | 5L | Copper tee air vent 22mm couple P/T valve Check valve | 46 | 11 |
IPSV150-NC/SC | 150L | IPRB A 581815 | 1 | 8L | 33 | 79 | ||
IPSV200-NC/SC/DC | 200L | IPRB A 581820 | 1 | 12L | 26 | 64 | ||
IPSV250-NC/SC/DC | 250L | IPRB A 581825 | 1 | 12L | 22 | 54 | ||
IPSV300-NC/SC/DC | 300L | IPRB A 581830 | 1 | 18L | 18 | 44 | ||
IPSV400-NC/SC/DC | 400L | IPRB A 581820 | 2 | 18L | 14 | 35 | ||
IPSV500-NC/SC/DC | 500L | IPRB A 581825 | 2 | 24L | 12 | 29 |