Smart Automatic Re-Closing Circuit Breaker MCCB 4p 125A Smart Grid Distribution Terminals

Price $49.42 Compare
Min Order 500 Pieces
Shipping From Zhejiang, China
Popularity 283 people viewed
Quantity
+-
 

Yueqing Long Road Electric Co., Ltd.

VIP   Audited Supplier 17 years
Profile Certified by SGS/BV
SRME1
Low Voltage Circuit Breakers
Auto Reclosing
High-Speed Circuit Breaker
Air
Fixed
MCCB
4p
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
ISO9001-2000, CE, CB, CCC
Srme1
4p
32~800A
AC415V/690V
Longroad/OEM
Exporting Package
IEC/EN 60947-2
China
Product Description
1.Application
The rated insulation voltage of series residual current operated circuit breaker is 1000V,which is suitable for three-phase four-wire neutral point direct grounding (TT)distribution networks with 50Hz AC,400V rated
voltage and 630A rated current.It is used to provide indirect contact protection;Prevent fire danger caused by grounding fault current due to equipment insulation damage;And it can be used to distribute electric
energy and it can also be used to distribute electric energy and protect lines and power supply equipment from overload,undervoltage,short circuit,single-phase grounding and other faults.
Products meet the following standards:Low-voltage Switchgear and Control Gear-Part 2:Circuit Breaker (IEC60947-2);
2.Main Functions and Features
1.High-performance  32-bit  ARM  microprocessor  is  used  to  carry  out  signal  processing  and  intelligent  control  in real  time;
2.LCD Chinese/English display provides friendly HMl and simple operation;
3.For residual current (leakage)protection,the residual current gear can be set online,with reclosing function;  Monitor and track the residual current of the line in realtime,and automatically adjust the gear to ensure the operation rate and reliability of the product;
4.Long delay,short delay and instantaneous three-stage protection,electronic tripping mode is applied,which s independent of supply voltage;
5.High breaking ability could ensure the reliability of short circuit protection for the line;
6.Overvoltage  protection,undervoltage  protection,phase  loss  protection;
7. Real-time display of residual current,three-phase supply voltage and load current of the line; 
8.Protection functions and parameters can be set and modified online;

9.Trip types (residual current,locking,overload,undervoltage,overvoltage,phase loss)can be identified & displayed,and can be stored,inquired &deleted;
10.Network type has communication function,which can realize remote communication,telemetry,remote control and remote adjustment.
11.Pluggable lightning protection module (optional)
12.Infrared communication function (optional)
3.Main Technical Parameters
Specification/ModelSRM1E-125CY
SRM1E-125CS
SRM1E-250CY
SRM1E-250CS
SRM1E-400CY
SRM1E-400CS
SRM1E-630CY
SRM1E-630CS
Shell grade rated current (A)125250400630
No.of poles3P+N3P+N3P+N3P+N
Rated operating voltage Ue:(V)AC   400/50HZ
Rated insulation voltage Ui (V)8001000
Rated impact withstand voltage (V)8000
Flashing distance (mm)×50≠100
Timit short circuit breaking capacit Icu  (kA)506585
Operating short circuit breaking capacity  Ics  (kA)354265
Rated residual short circuit on (off) capacity I△m (kA)12.516.2521.25
Rated short-time withstand current1.5358
Residual current operating featuresAC type
Rated residual operating
current I△n (mA)
50/100/200/300/400/500/600/800
MCU automatic tracking or manual setting
100/200/300/400/
500/600/800/1000
MCU automatic tracking ormanual setting
Residual operating time featuresDelayed/non-delayed type
Limit non-drive time of delayed type  (s)0.06:2I△n
Breaking time (s)I△n≤0.5;21△n≤0.2;51△n≤0.15
Auto re-closing time (s)20-60
Operational performance (times)Powered150010001000
Not powered850070004000
Total1000080005000
Overload and short circuit featuresThree-stage protection,electronically adjustable,see "Description of Protection features"for details
Overvoltage protection value (V)Setting value (250~300)±5%
Undervoltage protection value (V)Setting value (145~200)±5%
Link control delay time (ms)≤40ms
Communication delay time (ms)≤200ms

4.Description of Protection features
4.1Overload  long  delay protection
Sheet1:Overload Long Delay Parameters Setting operating value setting range
ParametersShell currentSet valueFactory setting value



operating setting
value Ir1
12550A,63A,80A,
100A,125A
125A
250100A,125A,140A,160A,
180A,200A,225A,250A
250A
400160A,180A,200A,225A,250A, 315A,350A,400A400A
630250A,315A,350A,400A,
500A,630A
630A
Delay time setting value tL3s,4s,6s,8s,10s
12s,16s,18s,OFF
12s
operating features                                                                      sheet2:Protection operating features
 
Ambient temperatureCurrent nameSetting current multipleAgreed time
+40ºCAgreed non-release current1.05Ir1≥2h
Agreed release current1.3Ir1<2h
 Delay features
Overload protection is carried out according to inverse time features:
T=(611)2tL Delay accuracy:10%,where T is the operating time value,Irl is the long delay protection setting value,listhe fault current,and tL is the long delay time setting value.
4.2 Short-circuit short-time delay protection
Short-circuit short-delay protection prevents impedance short-circuit of distribution system.The purpose of trip delay is to realize selective protection.
Setting of related parameters of short-circuit short-delay protection

                                                                    Sheet 3:Short Circuit Short-Delay Parameter Setting
 
Parameters settingSet valueFactory setting value
Setting value of short-de- lay operating current Ir22Ir1,2.5Ir1,3Ir1,4Ir1,5Ir1
6Ir1,7Ir1,8Ir1,10Ir1,12Ir1
6Ir1
Setting value of
short-delay time ts
0.1s,0.2s,0.3s,0.4s,0.6s,
0.8s,1.0s,OFF
0.4s
operating features of short-circuit short-delay protection
Sheet 4:Short-circuit Short-Delay operating features
 
featuresFault current multipleRelease featuresDelay error
Non-operating features≤0.85 Ir2Non-operating/
Activate features>1.15 Ir2Delay operating±40ms
 
4.3 Instantaneous  protection
Setting of related parameters of instantaneous protection
                                                                   Sheet 5:Instantaneous Parameters Setting
 
Parameters settingSet valueFactory setting value
Instantaneous operating  current setting value Ir34 Ir1,6 Ir1,7 Ir1,8 Ir1,9 Ir1,10 Ir1,
11 Ir1,12 Ir1,13 Ir1,14 Ir1,OFF
10 Ir1
operating features of short-circuit instantaneous protection
Sheet 6:Instantaneous operating Features
 
featuresCurrent multiple(l/lr3)Release featuresRelease time
Non-operating features≤0.85Non-operating≥200ms
Activate features>1.15operating<200ms
4.4Residual current protection features
Gear   setting   range
 
ParametersSetting value (125,250,400Setting value (630,800)Factory setting value
Residual operating
current I△n
50,100,200,300,400,500, 600,800 automatic100,200,300,400,500,60 0,800,1000 automatic500
 operating features
                                                                                                                                            Sheet 7:Protection operating features

 
ParametersParameters
Rated non-operating current Rated active current0.5I△n
≥0.75 l△n
Delay features21△n limit undriven time(△t)Segment time
l△n21△n5l△n
Non-delay ≤0.3s≤0.15s≤0.04s
0.06≥0.06s≤0.5s≤0.2s≤0.15s
Automatic gear mode
Each gear value and floating value in automatic gear mode:
 
Gear value (mA)Floating value (mA)
5025
10050
200100
300150
400200
500250
600300
800400
1000 
When the residual current is greater than the floating value of the gear but does not reach its operating value and stably maintains for 60s,the gear goes up a gear,and so on,until reaching the maximum gear;When the  residual current is less than the floating value of the next gear in this gear and stably maintains for 120s,the   gear goes down a gear,and so on,until reaching the minimum gear.Take "Gear 2"and the initial residual current of 100mA of the line as an example.The circuit breaker is powered on,and the gear is automatically set to 300mA.When the residual current increases to more than 150mA and stabilizes for 60s,the gear changes to gear 500mA;When the residual current decreases below 150mA and stabilizes for 120s,the gear changes to gear 200mA.
4.5 Automatic  reclosing
When the residual current exceeds the operating current value,the gear can automatically reclose after 20~   60s,but the manual closing is not limited by time.If the fault current is eliminated within 5s after closing,the closing is successful and the circuit breaker runs normally;If the fault current is not eliminated,the circuit breaker trips again and is locked,so it cannot be reclosed automatically,but must be closed manually.
4.6 Overvoltage protection function
When the line phase voltage is higher than the set value of overvoltage protection,the circuit breaker protection trips.When the line voltage returns to normal,the circuit breaker can be automatically closed for operation.The setting value range of overvoltage protection is 231V~330V,and the factory setting is 275V.    Users can set or close the protection.
4.7 Undervoltage  protection  function
When the line phase voltage is lower than the set value of undervoltage protection,the circuit breaker protection trips.When the line voltage returns to normal,the circuit breaker can be automatically closed for operation.
The setting value range of undervoltage protection is 88V~209V,and the factory setting is 145V.Users can set or close the protection.
4.8 Phase loss protection function
When the power supply terminal of the line is of phase loss,the circuit breaker protection trips. 
When the line voltage returns to normal,the circuit breaker can be automatically closed for operation.




compangy profile

       Longroad Electric Co.ltd founded in 2010,is located in the largest manufacturing base of low-voltage electric equipment of Liushi China.which is called"the Electric Device Metropolis of China"Longroad Electric specialized in the industrial electrical appliance,high-low voltage electrical equipment integrated with R&D,Manufacturing.International trade and service
       Longroad Electric Co,ltd regards quality of products as lifeLongroad Electric Coltd has been granted ISO9001 management system certifications.The comprehensive product line has more than 1000 models which have been approved by TUVCE,CQC. SGS.ROHS.SASO.the products sells well to UKSpain.PortuaalSingaporeTurkevRussiaKorea.South Africa.. more than 70 countries and regions
       Longroad Electric Co.ltd is always striving hard to provide the best services and competitve pricing to all customers.

Corporate Culture
 
      Enterprise policy:market oriented;technology driven; quality for survival;brand for developmentBusiness philosophy: provide value for customers: seek development for emplovees:take responsibilitv for societyTalent view the sea embraces all rivers and makes Jiaolong soar; the thousand boats compete to make the best of the worldQuality policy:people-oriented, pragmatic and
innovative: pursuina auality and servina the marketEnterprise spint:harmonymodesty.praamatism and developmentCustome
service: think for customers;be responsible for customers;make customers satisfiedEnterprise goal: to build an electrical manufacturing enterprise

service ldea

     "Intearity first.quality first"is the basic tenet of our companyOur quality policy is:installation specifications.timely maintenance. Abide by the contract.serve sincerelv and meet the needs of customers.We know that product auality is the basic and key factor of enterprise competitiveness, and service is the extension of product quality and one of the important factors of enterprise competition We are determined to treat our customers with"integrity":
1.All aspects of sincere service.That is.from the customer's electricity use report.enaineerina desian. euipment procurement installation and construction.eauipment commissionina and acceptancecompletion and power receivina to the test and detection during the future operation.We all provide all-round,whole process sincere service,try our best to meet the needs of customers.2,High quality returns.We strictly follow the provisions and requirements of the contract terms and engineering design on the equipment, and provide qualified products that meet the requirements,so as to complete the engineering construction and installation tasks within the specified time limit with the installation technology level
3,Active and stable aftercare service.We provide 24-hour emergency service after the project is powered on, that is, in case of abnormal operation of eauipment or accident power failure.as long as the customer calls us.we will rush to the site immediatelv remove the fault and resume power transmission