Tiankang electromagnetic flowmeter
±0.2-0.5%
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Industrial Production
Electromagnetic Flow Meter
Liquid
Electrical Principles
Closed Pipeline
CE, ISO
Highpeak
Wooden
China
9026100000
Product Description
Pioneering the future of flow measurement, this cutting-edge device leverages the international leading excitation technology, setting a new standard in precision and reliability.
With a simplified, stable, and highly reliable excitation circuit, this product embodies engineering excellence and state-of-the-art innovation.
Infused with the power of artificial intelligence, it offers unparalleled performance and adaptability, redefining flow measurement.
Engineered with no movable parts and no flow-resisting components, this design epitomizes efficiency and durability.
The pipeline remains free from any additional pressure loss, enhancing operational efficiency.
Exhibiting consistent measurement results, this device operates independently of flow velocity distribution, fluid pressure,
temperature, density, viscosity, and other physical parameters, ensuring the highest accuracy and reliability.
Its dynamic online range modification feature caters to the bespoke needs of users, offering customizable precision.
Versatile in application, it adeptly measures the flow of conductive fluids such as tap water, sewage, mud, and various beverages.
From chemical materials to viscous liquids and suspended solids, its low conductivity measurement capability broadens its adaptability.
Designed with explosion-proof safety, it complies with stringent national standards, having successfully passed all identification and
acceptance tests. This ensures its suitability for diverse explosion-proof environments.
The high resistance design ensures rapid response, adeptly capturing weak signals without distortion, and swiftly reflecting flow changes.
With a remarkable range ratio of 100:1, it provides unmatched flexibility and precision.
Utilizing capacitive technology for empty and full pipe detection, it prevents false alarms, ensuring operational integrity.
Consistency across converter swaps means no re-input of parameters is necessary, saving time and increasing efficiency.
Offering a wide range of power options (DC: 18V~36V, AC: 85V~265V), it ensures compatibility with various power conditions.
With a simplified, stable, and highly reliable excitation circuit, this product embodies engineering excellence and state-of-the-art innovation.
Infused with the power of artificial intelligence, it offers unparalleled performance and adaptability, redefining flow measurement.
Engineered with no movable parts and no flow-resisting components, this design epitomizes efficiency and durability.
The pipeline remains free from any additional pressure loss, enhancing operational efficiency.
Exhibiting consistent measurement results, this device operates independently of flow velocity distribution, fluid pressure,
temperature, density, viscosity, and other physical parameters, ensuring the highest accuracy and reliability.
Its dynamic online range modification feature caters to the bespoke needs of users, offering customizable precision.
Versatile in application, it adeptly measures the flow of conductive fluids such as tap water, sewage, mud, and various beverages.
From chemical materials to viscous liquids and suspended solids, its low conductivity measurement capability broadens its adaptability.
Designed with explosion-proof safety, it complies with stringent national standards, having successfully passed all identification and
acceptance tests. This ensures its suitability for diverse explosion-proof environments.
The high resistance design ensures rapid response, adeptly capturing weak signals without distortion, and swiftly reflecting flow changes.
With a remarkable range ratio of 100:1, it provides unmatched flexibility and precision.
Utilizing capacitive technology for empty and full pipe detection, it prevents false alarms, ensuring operational integrity.
Consistency across converter swaps means no re-input of parameters is necessary, saving time and increasing efficiency.
Offering a wide range of power options (DC: 18V~36V, AC: 85V~265V), it ensures compatibility with various power conditions.

The factory function safeguards settings, guaranteeing that the instrument parameters remain secure and foolproof.
Seamless operation is facilitated by infrared remote control and key operation, enhancing user convenience and ease of use.
Featuring sensor zero correction and automatic zero calibration, it maintains optimal accuracy at all times.
With a bilingual Chinese (English) interface, it caters to diverse user requirements, ensuring global applicability.
Equipped with converter self-calibration and self-check functions, it promises sustained operational efficacy.
An anti-lightning protected circuit with anti-interference capability makes it ideal for harsh environmental conditions.
Boasting digital communication signal output options like RS485, RS232, Hart, Modbus, and Profibus, it integrates seamlessly with existing systems.
With diverse protection levels and installation methods, converters and sensors cater to unique application needs, with IP68 level enabling submerged installation.
The inserted electromagnetic flowmeter excels in large pipe flow measurements, offering advantages in simplicity, installation without interruption, and cost-effectiveness.
Its measurement precision is linked solely to the depth of insertion, making it highly interchangeable and adaptable for various pipeline measurements.
This type can be applied broadly across different specifications of pipeline fluid measurement, reflecting its versatile prowess.
The inserted technology ensures that the process is seamless, offering both installation convenience and cost benefits.
The versatility of this flowmeter makes it indispensable, seamlessly adapting to an array of applications and specifications.
Its capability to measure across diverse pipeline specifications showcases its comprehensive application range and high interchangeability.
of specifications of the pipeline fluid measurement.
Seamless operation is facilitated by infrared remote control and key operation, enhancing user convenience and ease of use.
Featuring sensor zero correction and automatic zero calibration, it maintains optimal accuracy at all times.
With a bilingual Chinese (English) interface, it caters to diverse user requirements, ensuring global applicability.
Equipped with converter self-calibration and self-check functions, it promises sustained operational efficacy.
An anti-lightning protected circuit with anti-interference capability makes it ideal for harsh environmental conditions.
Boasting digital communication signal output options like RS485, RS232, Hart, Modbus, and Profibus, it integrates seamlessly with existing systems.
With diverse protection levels and installation methods, converters and sensors cater to unique application needs, with IP68 level enabling submerged installation.
The inserted electromagnetic flowmeter excels in large pipe flow measurements, offering advantages in simplicity, installation without interruption, and cost-effectiveness.
Its measurement precision is linked solely to the depth of insertion, making it highly interchangeable and adaptable for various pipeline measurements.
This type can be applied broadly across different specifications of pipeline fluid measurement, reflecting its versatile prowess.
The inserted technology ensures that the process is seamless, offering both installation convenience and cost benefits.
The versatility of this flowmeter makes it indispensable, seamlessly adapting to an array of applications and specifications.
Its capability to measure across diverse pipeline specifications showcases its comprehensive application range and high interchangeability.
of specifications of the pipeline fluid measurement.




Model | TK1100 standard series | TK1200 high accuracy series |
Caliberl | DN3-DN2200 | DN10-DN300 |
Accuracy | 0.5% | 0.2%,0.3% |
Installation method | Hold,flange | Hold,flange |
Repeatability | 0.1% | 0.06%,0.1% |
Measuring range | 0-12m/s(flow unit can be changed) | 0-12m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | GB/T9119-2000 or any other choice |
Pressure | 4.0MPa~0.25 Mpa (classify by caliber) | 4.0MPa~0.25 Mpa (classify by caliber) |
Lining material | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard,(scraper,it can be replaced by DN>350) | Standard,(scraper,it can be replaced by DN>350) |
Protection level of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >5μS/cm(water>20μS/cm) | >2μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) | Integrated type≤90ºC,split type≤160ºC(rubber) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | Integrated,split | Integrated,split |
Output signal | 4-20mA current signal,frequency /pulse output | 4-20mA current signal,frequency/pulse output |
Power supply | AC:85V~265V,DC:18V~36V | AC:85V~265V,DC:18V~36V |
Self diagnosis | yes | yes |
Zero setting of empty pipe | yes | yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,HART,PROFIBUS |
Explosion-proof | No explosion proof/explosion proof | No explosion proof/explosion proof |
Language | Chinese,English | Chinese,English |
Product standards | JB/T 9248-1999 | JB/T 9248-1999 |


Model | TK1300 hygienic series | TK1500 battery powered series |
Caliberl | DN3-DN150 | DN10-DN1200 |
Accuracy | 0.2%,0.5% | 0.5% |
Installation method | Thread,clamp | Hold,flange |
Repeatability | 0.06%,0.1% | 0.15% |
Measuring range | 0-12m/s(flow unit can be changed) | 0-10m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | |
Pressure | The highest 4.0MPa | 4.0MPa~0.6 Mpa (classify by caliber) |
Lining material | PFA(negative pressure resistance) | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard | Standard,(scraper,it can be replaced by DN>350) |
Protection leve of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >2μS/cm(water>20μS/cm) | >5μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤160ºC | Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | ntegrated,split | Lntegrated,split |
Output signal | 4-20mA current signal,frequency/pulse output | Frequency 0-5kHz |
Power supply | AC:85V~265V,DC:18V~36V | 3.6V |
Self diagnosis | Yes | Yes |
Zero setting of empty pipe | Yes | Yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,GPRS |
Explosion-proof | No explosion proof/explosion proof | |
Language | Chinese,English | Chinese,English |
Product standards | JB/T 9248-1999 |



Model | TK1400 inserted type series | TK1600 electromagneticheat meter series |
Caliberl | DN200-DN3000 | DN15-DN1200 |
Accuracy | 1.5%;2.5% | 1.0%,2.0%,2.5% |
Installation method | Flange,thread,on-line | Hold,flange,thread |
Repeatability | 0.5% | 0.3%;0.5% |
Measuring range | 0-10m/s(flow unit can be changed) | 0-12m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | GB/T9119-2000 or any other choice |
Pressure | 1.6MPa | 4.0MPa~0.6Mpa (classify by caliber) |
Lining material | POM,PTFE,PFA | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard | Standard |
Protection level of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >5μS/cm(water>20μS/cm) | >5μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) | Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | Integrated,split | Integrated,split |
Output signal | 4-20mA current signal,frequency/pulse output | 4-20mA current signal,frequency /pulse output |
Power supply | AC:85V~265V,DC:18V~36V | AC:85V~265V,DC:18V~36V |
Self diagnosis | Yes | yes |
Zero setting of empty pipe | Yes | yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,HART,PROFIBUS |
Explosion-proof | No explosion proof/explosion proof | No explosion proof/explosion proof |
Language | Chinese,English | Chinese,English |
Product standards | Refer to 9248-1999 JB/T |

Cold Valley Intelligent Technology (Shanghai) Co., Ltd. emerges as a shining beacon of innovation and excellence, proudly under the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. group. Renowned for its commitment to cutting-edge advancements, Cold Valley stands as a leader in the industry.
Established in the bustling metropolis of Shanghai in 2013, Cold Valley serves as an esteemed affiliate of Hanshan Intelligent Technology Co., Ltd., celebrated for its pioneering role and outstanding leadership in the industry.
Our team comprises elite founding experts from prominent global automation companies, collectively bringing over two decades of rich experience in automation and engineering. With a robust expertise spanning a decade in consulting and digital strategies, we pledge to offer unmatched automation and digitization products and services, orchestrated from our thriving Shanghai headquarters.
With an impressive legacy exceeding 20 years in the industry, we have carved a niche in the petrochemical sector. Our profound understanding of the automation and digitalization needs of enterprises at every phase empowers us to deliver tailored products and solutions. We provide full-cycle services across diverse industries, including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, all enhanced with state-of-the-art automation and digitalization.
Established in the bustling metropolis of Shanghai in 2013, Cold Valley serves as an esteemed affiliate of Hanshan Intelligent Technology Co., Ltd., celebrated for its pioneering role and outstanding leadership in the industry.
Our team comprises elite founding experts from prominent global automation companies, collectively bringing over two decades of rich experience in automation and engineering. With a robust expertise spanning a decade in consulting and digital strategies, we pledge to offer unmatched automation and digitization products and services, orchestrated from our thriving Shanghai headquarters.
With an impressive legacy exceeding 20 years in the industry, we have carved a niche in the petrochemical sector. Our profound understanding of the automation and digitalization needs of enterprises at every phase empowers us to deliver tailored products and solutions. We provide full-cycle services across diverse industries, including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, all enhanced with state-of-the-art automation and digitalization.




Frequently Asked Questions
How to Choose the Right Product?
A: Upon receiving your inquiry, we swiftly furnish you with a comprehensive technical document. This allows you to meticulously assess essential process parameters and technical specifications. Based on your distinct requirements, we offer a personalized recommendation for the model that is finely tuned to meet your needs.
Desire a Confirmed Model?
A: Certainly. Once we receive your model specification, we will meticulously verify its suitability and, if necessary, propose further cost-effective optimization options. Upon agreement, we will advance with a comprehensive formal quotation to initiate the process.