ZJR2-31320
We Focus on After Sales Service
Balance The Current When The Motor Starts .Only Wo
Automatic
New
CCC, ISO, CE
16 Months
Manual
Manual
Electric
>1,000,000 Shots
Gray
5.5kw~600kw
Three Phase 380V-15% ~ 415+10%
50/60Hz
Squirrel-Cage Three-Phase Asynchronous Motor
It Is Recommended Not to Exceed 20 Times Per Hour.
21kg
25kg
Paper Box
Yes
IP20
CHZIRI, OEM Service
Stardard Export Package
CE CCC ISO9001
Wenzhou, China
8537101990
Product Description
Various Soft Starter,Inverters for Fruit cleaning assembly

Our customers use soft starter for livestock farms to run pumps.Very popular!!!
Of course ZJR2 Series Soft Starter motor also applies to centrifuges,blower,compressor,transport planes,mixer,rolling ball mill broken machines and mechanical equipment motor starter.
ZJR2 series meet our customers' requirements:
Suit----------------------- The soft starte is balance the current when the motor starts,only work when the motor is starting.
Economical---------------------- We are the manufacturer specialized in soft starter and inverter since 1998.Manufacturers mean better prices and faster shipping.Good after service.We support each of our customers and offer them competitive prices.Consideration for our customers is always our tenet.
It is easy to operate-------------------- All the software and hardware are researched and developed by CHZIRI engineers.We have instructions in English on how to use our soft starter.
ZJR2 Series from 5.5kw to 55kw the dimensition is same,please check below:


CHZIRI Soft start installation scene diagram.

DIMENSION:(UNIT:MM)
Technical Indications
CHZIRI Soft starter Wiring Diagram:

Customers we've worked with

CE CERTIFICATE OF CHZIRI PRODUCT

CUSTOMER SUPPORT
RETURNS
Please note that all returns must be pre-approved by us.Unauthorized returns will not be accepted.If you need to return,please check twice to confirm the item not work and contact our customer service representative,let us know the detailed problem and send us some pictures for confirmation.

Our customers use soft starter for livestock farms to run pumps.Very popular!!!
Of course ZJR2 Series Soft Starter motor also applies to centrifuges,blower,compressor,transport planes,mixer,rolling ball mill broken machines and mechanical equipment motor starter.
ZJR2 series meet our customers' requirements:
Suit----------------------- The soft starte is balance the current when the motor starts,only work when the motor is starting.
Economical---------------------- We are the manufacturer specialized in soft starter and inverter since 1998.Manufacturers mean better prices and faster shipping.Good after service.We support each of our customers and offer them competitive prices.Consideration for our customers is always our tenet.
It is easy to operate-------------------- All the software and hardware are researched and developed by CHZIRI engineers.We have instructions in English on how to use our soft starter.
ZJR2 Series from 5.5kw to 55kw the dimensition is same,please check below:


CHZIRI Soft start installation scene diagram.

DIMENSION:(UNIT:MM)
Soft starter Model | Rated Power(KW) | Rated Current (A) | Outline Size | Install Size | Net Weight | ||||
ZJR2-31600 | 160kW | 320A | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
Technical Indications
Item | Item Description | ||
Input Power Supply | Input Voltage | Three Phase 380V-15% ~ 415+10% | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. | ||
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | 1) Soft stop; 2) Free stop. | ||
Protective Function | Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 3000M. It have to rise the rate power when the altitude is more than 3000M. | ||
Ambient Temperature | -30~+55ºC | ||
Ambient Humidity | ≤90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
CHZIRI Soft starter Wiring Diagram:

Customers we've worked with

CE CERTIFICATE OF CHZIRI PRODUCT

CUSTOMER SUPPORT
- Email Customer Support:
- 8:30am-:16:45pm Sunday-Friday
- All emails will be responded to within 12-24hours
RETURNS
Please note that all returns must be pre-approved by us.Unauthorized returns will not be accepted.If you need to return,please check twice to confirm the item not work and contact our customer service representative,let us know the detailed problem and send us some pictures for confirmation.