CEMI-075
One Year
New
CEMI
Carton
China
8502310000
Product Description
Product Introduction
MPPT Hybrid Wind Solar Charge Controller



Product Parameters
Technical Parameters | ||||||
Model | JW1230 | JW1240 | JW1250 | JW2450 | JW2460 | |
Rated voltage | 12v/24v auto | 12v/24v auto | 12v/24v auto | 24V | 24V | |
Solar panel power | 100W | 100W | 100W | 300W | 400W | |
Wind turbine power | 300W | 400W | 500W | 500W | 600W | |
Charging | Charging current | 33.33A | 41.66A | 50A | 33.33A | 41.66A |
Equalization charge | 14.4V±1% | 28.8V±1% | ||||
Floating Charge | 13.8V±1% | 27.6V±1% | ||||
Equalization charge recovery | 13.2V±1% | 26.4V±1% | ||||
Temperature Compensation | -24mV/ºC | -48mV/ºC | ||||
Over Discharge | Disconnect (DC) | 10.8V±1% | 21.8V±1% | |||
Recovery (DC) | 12.3V±1% | 24.6V±1% | ||||
Over Voltage | Shut off (DC) | 16V±1% | 32V±1% | |||
Recovery (DC) | 15V±1% | 30V±1% | ||||
No-load | ≤0.1A | ≤0.1A | ||||
Voltage drop (DC) | ≤0.5V | |||||
Control mode | Wind generator MPPT charge function, PWM uninstall function, PWM over-current limiting | |||||
Boost charge | Flexible independent step-up circuit (optional) | |||||
Display | LCD | |||||
Show parameters | Voltage,charge current,battery voltage | |||||
Protected type | Lightning protection, solar cell anti-reverse protection, open battery protection, reverse battery protection, over-wind speed and over-voltage soft automatic braking protection | |||||
Heat emanation way | Radiator | |||||
Working Temperature | -25ºC~+55ºC | |||||
Height | ≤5500m(2000m above the need to reduce power use) | |||||
Environment humidity | 0~90%,No condensation |


12/24V auto and 48V independent system
Fit all kind of batteries, Lead acid, Gel, LIFEPO4, LiNiCoMn
Advanced MPPT maximum power point tracking
technology,tracing efficiency > 99.5%, maximum
conversion efficiency > 98%; full-load efficiency
can reach 97%
Fit all kind of batteries, Lead acid, Gel, LIFEPO4, LiNiCoMn
Advanced MPPT maximum power point tracking
technology,tracing efficiency > 99.5%, maximum
conversion efficiency > 98%; full-load efficiency
can reach 97%
Dump load resistance is default part, no need pay
additional for it
Comprehensive protection functions : overcharge,
over discharge and overload etc
In the high wind speed or fan's power is beyond scope of
battery and load absorption, controller immediately launched
step-less unloading resistance protection system
additional for it
Comprehensive protection functions : overcharge,
over discharge and overload etc
In the high wind speed or fan's power is beyond scope of
battery and load absorption, controller immediately launched
step-less unloading resistance protection system


It has various load control modes, DC load has two route outputs, output power and time can be set
Time Control: street light & household
Street light mode: time can be set by UP & DOWN keys,
default Value "15H", you can set other hours as you want,
this time set is street light work time at night.
Household mode: time is "24H", it means DC load
need work at 24H
Time Control: street light & household
Street light mode: time can be set by UP & DOWN keys,
default Value "15H", you can set other hours as you want,
this time set is street light work time at night.
Household mode: time is "24H", it means DC load
need work at 24H