Solid-Phase Microextraction Probe Specification 75μ M Pdms/DVB/Car Suitable for Mass-M01 PRO Spme

Price $227.54 Compare
Min Order 1 Bag
Shipping From Fujian, China
Popularity 472 people viewed
Quantity
+-
 

Raykol Group (XiaMen) Corp., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
MASS-M02
36 Months
1 Years
Non-Disposable
Solid
Metallic Material
Gc
Three Piece
DVB/Car/Pdms
OEM, ODM
RayCure
Back
small equipment
China
9031809090
Product Description
Product Description
Part NumberPart Description
MASS-M30Manual Solid Phase Microextraction (SPME) Device-Metal bath version includes:
Equipment(including mounting bracket and temperature probe)*1
Metal bath heating module, for 6 positions*1
magnetic stir bar*5
SPME Holder*1
SPME fiber(75μm  Divinylbenzene/Carboxen/Polydimethylsiloxane,DVB/CAR/PDMS coating),3/PK*1
60mL brown bottle*5
Inlet guide*1
Bottle mouth adapter*1
MASS-M03SPME Holder
MASS-M02SPME fiber(75μm  Divinylbenzene/Carboxen/Polydimethylsiloxane,DVB/CAR/PDMS coating,black),3/PK
SPME-C-01SPME fiber(75μm  Polydimethylsiloxane,PDMS coating,white),3/PK
SPME-C-02SPME fiber(75μm  Divinylbenzene/Polydimethylsiloxane,DVB/PDMS coating,khaki),3/PK
SPME-C-05SPME fiber,Empty syringe without stainless steel wire carrier, beige,3/PK
MASS-M1260mL brown bottle,100/PK
MASS-M1360mL brown bottle,cap and liner,100/PK
MASS-M17Magnetic stir bar,Length 15mm, inner diameter 1.5mm,100/PK
MASS-M18Magnetic stir bar,Length 15mm, inner diameter 7mm,100/PK
MASS-M2112mL Brown storage bottle with solid cap,100/PK
MASS-M2222mL Brown storage bottle with solid cap,100/PK
MASS-M2340mL Brown storage bottle with solid cap,100/PK


Manual Solid-Phase Microextraction (SPME) is a technique used for sample preparation and analysis, and several considerations should be taken into account during operation:
1. **Fiber Selection**: Choose an appropriate extraction fiber coating based on the nature and concentration of the target analytes. Different coatings have varying affinities for different compounds.
2. **Fiber Pretreatment**: Before use, pretreat the fiber according to the manufacturer's guidelines to ensure extraction efficiency.
3. **Sample Preparation**: Ensure that the sample is uniform before extraction. If necessary, stir or heat the sample to help volatile analytes evaporate.
4. **Operating Temperature**: Depending on the volatility of the target analytes and the characteristics of the sample, extraction may need to be performed at a specific temperature to optimize results.
5. **Extraction Time**: Determine the appropriate extraction time based on the concentration of the analytes and the type of fiber. Too short a time may result in incomplete extraction, while too long may lead to the adsorption of excessive interfering substances.
6. **Stirring**: Stirring the sample during extraction can help the analytes be adsorbed by the fiber more quickly, thereby improving extraction efficiency.

 

Company Profile



Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol's automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.

With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories.We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.

Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.

Raykol Patents
Company Culture

 
Mission

Innovation creates values, Knowledge optimized laboratory

 
Vision

World-leading manufacturer and supplier for laboratory automation systems and services

 
Value

Dedication, innovation, motivation, cooperation


Company Certificate

RayKol Group has been certified as SGS Excellent Supplier in China mainland since July 2023.




Q1. Are you factory or trading company?

We are a factory.

Q2. What's the MOQ?
(1). Normally, MOQ is 1 piece. But if the items are in stock,there is no MOQ. The quantity is according to the clients requires.
(2). If there is no stock,the general MOQ are in big difference due to the different products. But the quantity still can be negotiated.

Q3. What is your principle for the samples?
We do not provide free sample.

Q4. Which payment can be acceptable ?
We could accept the payment by T/T, etc.

Q5. How about your delivery time?
Generally, it will take 7 to 15 working days after receiving your advance payment. Depend on the quantity.

Q6. Certificate & Quality.
CE and ISO certified for most products. Good quality firstly to avoid any defective products, Protective packaging to avoid destroy during delivery.

Q7. Language.
Pure English operation panel, display , manuals ; installation & operation videos will be provided to you as a guidance.

Q8. Service
We could provide Online instruction; Real-time support by video-call or voice-chat, During warranty time, we can send product accessories when you need for free; Technical guidance is free and ready forever.

Q9. Training
Your technicians can come to our factory for training,
Products can be customized according to your requirements; OEM service is available with customers' brand.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA