Solis-(215-255)K-EHV-5G
Customized Services Are Available
5 Years
Three
215-250kw
CE, CCC, TUV, IEC
Solis
DC/AC Inverters
Solar Power, Utility Grid
Sine Wave Inverter
215-255kw
30A
113 Kg
215-255kw
1500V
3/N/PE, 220 V / 380 V, 230 V / 400 V 50 Hz / 60 Hz
480-1500V
IP66
RS485, Optional: Wi-Fi, GPRS
LCD
G99, VDE-Ar-N 4105 / VDE V 0124, En 50549-1, VDE 0
Solis
1PCS/Carton
1125*770*384 mm
China
850440
Product Description
Solis Three Phase Inverters
Solis-GC(100-125)K
S5-GC(100-125)K three-phase series string inverter adopt 10 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Anti-resonance, supporting over 6MW paralleled in one transformer, Strings intelligent monitoring, Smart I-V Curve Diagnosis supported
100-125kW Three Phase Inverter Leading Features:
Applications:
Villa, Hotel, Residential electricity, Hospital, Museum, Church, Farm

DATASHEET | Solis-(215-255)K-EHV-5G | |||||||||
Models | 215K-PLUS | 250K | 250K-PLUS | 255K | 255K-PLUS | |||||
Input DC | ||||||||||
Max. input voltage | 1500 V | |||||||||
Rated voltage | 1080 V | |||||||||
Start-up voltage | 500 V | |||||||||
MPPT voltage range | 480-1500 V | |||||||||
Max. input current | 9*30 A | 14*26 A | 12*30 A | 14*26 A | 12*30 A | |||||
Max. short circuit current | 9*50 A | 14*40 A | 12*50 A | 14*40 A | 12*50 A | |||||
MPPT number/Max. input strings number | 9/18 | 14/28 | 12/24 | 14/28 | 12/24 | |||||
Output AC | ||||||||||
Output power | 215 kVA@30°C / 205 kVA@ 40°C / 195 kVA@50°C | 250 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C | 255 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C | |||||||
Rated grid voltage | 3/PE, 800 V | |||||||||
Grid voltage range | 640-920 V | |||||||||
Rated grid frequency | 50 Hz / 60 Hz | |||||||||
Max. output current | 155.2 A | 180.4 A | 184.0 A | |||||||
Power factor | >0.99 (0.8 leading - 0.8 lagging) | |||||||||
THDi | <3% | |||||||||
Efficiency | ||||||||||
Max. efficiency | 99.0% | |||||||||
EU efficiency | 98.8% | 98.7% | 98.8% | 98.7% | 98.8% | |||||
Protection | ||||||||||
DC reverse-polarity protection | Yes | |||||||||
Short circuit protection | Yes | |||||||||
Output over current protection | Yes | |||||||||
Surge protection | DC Type II / AC Type II | |||||||||
Grid monitoring | Yes | |||||||||
Anti-islanding protection | Yes | |||||||||
Temperature protection | Yes | |||||||||
Strings monitoring | Yes | |||||||||
I/V Curve scanning | Yes | |||||||||
Night time SVG function | Yes | |||||||||
Integrated PID recovery | Yes | |||||||||
Integrated DC switch | Yes | |||||||||
General Data | ||||||||||
Dimensions (W*H*D) | 1125*770*384 mm | |||||||||
Weight | 109 kg | 113 kg | ||||||||
Topology | Transformerless | |||||||||
Self-consumption (night) | <2 W | |||||||||
Operating ambient temperature range | -30 ~ +60°C | |||||||||
Relative humidity | 0-100% | |||||||||
Ingress protection | IP66 | |||||||||
Cooling concept | Intelligent redundant fan-cooling | |||||||||
Max. operation altitude | 4000 m | |||||||||
Grid connection standard | EN50549, G99, AS4777.2, VDE0126, IEC61727, VDE4110, CEA 2019 | |||||||||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 | |||||||||
Features | ||||||||||
DC connection | MC4 connector | |||||||||
AC connection | OT terminal (max. 300 mm²) | |||||||||
Display | LCD | |||||||||
Communication | RS485, Optional: PLC |

On Grid Residential Inverter
0.7-10KW
1-3 MPPTs
Single Phase 220-240V 50/6Hz
Single Phase 220-240V 50/6Hz
On Grid Residential Inverter
3-20KW
2 MPPTs
Three Phase 380-415V 50/6Hz
Three Phase 380-415V 50/6Hz


On Grid Commercial Inverter
25-70KW
5/6 MPPTs
Three Phase 380-415V 50/6Hz
Three Phase 380-415V 50/6Hz
On Grid Commercial Inverter
50-125KW
10 MPPTs
Three Phase 380-415V 50/6Hz
Three Phase 380-415V 50/6Hz


On Grid Utility Scale Inverter
215-255KW
9-14 MPPTs
Three Phase 800V 50/6Hz
Three Phase 800V 50/6Hz