Profile Certified by SGS/BV
Sonoscape E2
Non-Customized
CE, ISO13485
Large
Echo Machine Echocardiography
B /2b/4b/M/ Steer M (Optional)/Color/Dpi/Pw/ Cw (O
15-Inch High Definition LCD Monitor
2D, Freehand 3D(Optional) and 4D Imaging (Optional
Convex, Linear, Transvaginal, Transrectal, Micro-C
Spatial Compound Imaging, Panoramic Imaging, Anato
Freehand 320g Hard Drive
1 Hour Support
2
Dicom 3.0, LAN Port, VGA Port, Support Flash Disk
Sonoscape
Sonoscape
Standard Package for Export
CE, ISO
Guangzhou
Product Description


Sonoscape E2 Portable 4D Color Doppler Ultrasound Scanner

Model: Sonoscape E2
 

E2 is a color Doppler ultrasound system that reaches beyond your expectations due to its compact and fashionable appearance.
It fulfills GI, OB/GYN, Cardiac and POC applications to fit your routine scanning needs while its color mode will help you for more accurate and efficient diagnosis of lesions.

 

 

E2 provides wide range of applications to assist users for routine scanning.


Auto Image Optimization

With the press of a button the image is automatically adjusted and optimized, saving you time with parameter adjustments. Additionally, with Auto Focus on, the focus area follows the depth of the ROI box as it is moved in the scanning field, providing users an excellent image quality in the desired area of interested.


Automated Calculation
E2 provides automatic calculations to enhance your diagnostic confidence and save you time for patient communication.
1. Auto IMT is used when determining the level of vascular sclerosis present in the patient
    by automatically tracing the thickness of the carotid vessels.
2. Auto trace provides users sensitive and accurate wave tracing, avoiding error of manual
    trace and giving out calculation result in no time




Specification:
ItemSpecified
General Requirement
Released with in 1 yearsreleased at least at 2017
Operation SystemLinux Platform(stable and will not infect by virus)
Sizemaximum: L×W×H(mm):  352mm×378 mm×114mm 
WeightLess than 6.5kg
Multiple Beam Processingrequired
Applicationshave a wide range of applications includes: abdominal, OB/Gyn, cardiology, urology, small parts, vascular, orthopedic, anesthesia and MSK.
Application icomAll the applcation shows in unique icom
Monitorno less than 15.6 inch,LCD monitor, widescreen,anti-flickering, can be vertically and horizontally swiveled
KeyboardPC back light Keyboard on the control panel
Monitor and Key botard Bright Auto AdjustmenMonitor and Keyboard Bright Auto Adjustmen
WIFI connectionrequired
Solid State Diver(SSD)can be choosed in optional
Fast Boot upWith in 30s
Stand byrequired
Operation ModeB Mode
Dual B
Quad B
Color Doppler
Directional PDI
TDI
Power Doppler Imaging
SR Flow Imaging
Dual-Live
Pluse inversion Harmonic Imaging ( PHI )
Trapezoid Imaging (Linear And Convex)
Real-time Panoramic Imaging(B mode )
M Mode
Anatomic M Mode
Color M Mode
PW ,CW
Duplex: B/M, B/PW, can be defined in new preset
Screen Zoom
Compound Imaging (1,2,3,4)
u-scan(Speckle Reduction)
Needle enhancement ( Vis-needle )
Transducer Socket2 active transdcuer connectors, which can support all transducers. 
Transducerscan supply with more than 10 transducer choices, covering linear, convex, endocavity, phased array, micro-covex and intra-operation probe.                           
Scanning MethodsElectronic Convex Secter
Electronic Linear Secter
Electronic Phased Array Sector
ECGsupport ECG function
Clipboard FunctionCapture and reviewthe archived images, support output the images and viedo to USB and DVD in scanning interface
Image Optimization Images can be optimized by one button in B mode and PW mode
TGCrequired
LGC required
ZoomThe zoom value can be shown.The minimum zoom ratio can low to 0.8. The max zoom ratio can up to 10. 
Full Screen Zoomrequired
Auto foucsrequired
Biposysupport 2 needle guide line and 1 gun guide line
Warrantyspare parts should be provided with system for 18 months
Scanning Parameters 
B Mode
Dynamic Rangeat least 20-280dB(Probe dependent) can be adjusted by 20dB/step.
Gain1~255, adjustable
Depth40cm Maximum
ChromaMaximum 12 selectable
Frequency5 bands
PersistenceLow, Med, High, Max 4 levels
Grayscale curve16 types
Line Densitycan choose the lower line density for higher frame rate, and line density can be adjusted by 3 levels: low/med/high
u-scanSpeckle Reduction Imaging,adjustable
Compound Imagingrequired,adjustable
Live Panoramic imagingrequired
Trapezoidal imagingImage area extend for linear
Convex extensionImage area extend for convex 
Biopsy guide functionrequired,and the biopsy line adjustable.
Imaging width and positionadjustable
Tissue Specific Imaging provide different choices for tissue scanning when scanning in different orgens
Image Optimization by one buttonrequired
B-steerrequired,at least the Linear probe
Color Doppler Mode
Frame Rateup to 209 f/s
Auto foucsrequired
Pulse Repetition Frequency0.5~10KHz
Steer Angleup to 16 degrees
Wall filter5 levels, Min, Low, Med, High, Max adjustable(Probe dependent)
Baseline±4 steps, adjustable
Persistence:4 levels, Off/Low/Med/High/Max adjustable (Probe dependent)
Image orientationleft/right, up/down
Flow Invertrequired
Color /Direction energyat least 7 kinds,selectable
SR FlowHighly sensitive blood flow detection technology
Line densitycan be adjusted by 4 levels:min/low/medium/high
B and Color Flow Simultaneous Realtime Displayrequired
M Mode
Sweep Speedadjustable, at least 5 levels
Video Inversion Functionrequired
Chromaat least 12 types
Display Formatat least 5 types
Steer M up to 3 lines 
Spectral Doppler
PRFPW : 1~16KHz
CW: 1-50KHz
Maximum Velocity RangePW: 0.0576 - 6.14m/s
CW: 0.0761 - 10.35m/s
Baseline9 steps
Frequency3 bands
Angle Correction0~88 degree, 2 degree per step or less
Auto Angle CorrectionAuto 60 degree of Angle correction by one botton
Sample Volume in PW Doppler0.5~24 mm, adjustable
Sweep Speedadjustable, at least 5 levels
Chroma12 types
Video Inversion Functionrequired
Spectrum Inversionrequired
Real Time Auto-Tracerequired
Wall Filter5 levels, Min, Low, Med, High, Max, adjustable 
One-key Auto OptimizationAt least can adjust the baseline, PRF
Steer angle4 levels: 0°, ± 8°,± 12°, ± 16°, adjustable
Auto foucsrequired
Display Format5
Transducer
Transducer Warrantytransducers are manufactured by supplier, and the warranty should last 18 months
Transducer Frequencybroadband (1.0~16MHz) with multiple 5 frequencies range in B Mode/Color Mode/PIH Mode/PW mode/CW/Mode
Transducer Elementsat least 128
Linear Transducerfrequency range: 4~16MHz 
Convex Transducerfrequency range: 1~15MHz
Endocavity transducerfrequency range: 3~15MHz
scanning angle: 135°, can extend to 193°
Phased Arrayfrequency range: 1~9MHz
Biopsy GuideRequired
Image Storage
Cine Loopavailable for all mode
Retrospective Storage27s retrospective saved in real time
Prospective Storage480s prospective saved in real time
Freeze Storagerequired
Image FormatJPG, BMP, TIF
Clipboard functionis avilibale in frozen B mode
Clip FormatWMV, AVI
One Key Saverequired
Doppler cine playbackspeed is adjustable, sound can be played back
Print&Store RegionFull Screen, Image&Result Area, US Image
Image Share Servicerequired
Store To UsbDiskrequired
Storage CapabilityHard Disk can up to 500G/1T; SSD can up to 128GB
Report TablesAbdominal, OB/Gyn, Cardiology, Urology, Small Parts, Vascular,IMT 
Report FormatTXT, PDF
Report Templetat least 6 images can be displayed in report
Measurements
Measurement PackagesAbdominal, OB/Gyn, Cardiology, Urology, Small Parts, Vascular, Orthopedic, and measurement packages can be chosen for Icon Driven or All Packages
Measurement in B Moderequired
Measurement in M Moderequired
Measurement in PW Moderequired
Short cut key for obstetrics measurementrequired
Quick MeasurementsMeasurement can be select by one button
IMT Measurementsupport IMT measurement, and the result can be displayed in report
Obstetrics Packages 
Measurement itemsIncluding GS, CRL, BPM, HC, AC and AFI.
Formulausers can define the formula by themselves
Fetal Growth Chartrequired
Cardiac Packages 
B Moderequired
M Moderequired
PW ModeReal Time Automatic Measurement
Annotations
Commentsusers also can define it by themselves
ArrowOrientation adjustable
Body MarkClassified by specific exams
Input and Output
DVD-R/WRequired
FootswitchRequired
S-video outputRequired
USB Port3 ports
VGA/HDMI outputRequired
Printer interfaceVideo printer
Ethernet port for DICOMRequired
Preset Function
Preset FunctionRequired, can be customized
User Define KeyRequired, can be customized
The sequency of presetsUsers can arrange the presets
import or export presetsRequired
Laguages support
System Laguages supportEnglish, Simplified Chinese, Spanish, Russian, French, Italian, Germany, Norwegian,Portuguese
Qualification documents
CE certificationRequired
ISO 13485Required