Standard Laboratoey Equipment Analysis Machine Atomic Absorption Spectrophotometer

Price $24558.00 Compare
Min Order 1 Set
Shipping From Shanghai, China
Popularity 411 people viewed
Quantity
+-
 

Macylab Instruments Inc.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
AA-1800EL
Online Technical Support
Laboratory Apparatus
1 Year
Spectrograph
High Sensitive
Classic Spectrometer
Infrared Spectrometer
Grating Spectrometer
Monochromator
RoHS, ISO9001, CE
Customized
8lamps Automatic Turret
Pulsed Power Supply
Full Closed Optical System
<0.1nm
Macylab
Carton
1250*590*584mm
Jiangsu
9027300000
Product Description
AA-1800EL Atomic Absorption Spectrometer 
   
    
AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

    AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

 

Product Description

High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be respectively preheating

Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system 6 lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak


Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

Graphite furnace temperature control
Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade.

High technology index
AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h

Background correction system
Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A,
background correction ability > 60 times


Intelligent analysis
Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function

Automatic sampler
Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function.

 
Product Parameters

 

Light Source

≤8 lamps automatic turret, automatic alignment

Power Supply

110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current

pulsed power supply

Optical System

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

185nm-900nm Automatically peak find,a key opticaloptimization function

Wavelength Accuracy

±0.15nm

Wavelength Repeatability

<0.1nm

Spectral Bandwidth

0.1,0.2,0.4,0.7,1.0,1.4,2.0nm (7 steps with automatic changeover)

Baseline Stability

≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

Absorbance Range

0-4A


Flame Analytical System
 

Detector

imported photomultiplier tube

Burner Head

full titanium combustion head, 50mm or 100mm generalcombustion head

Atomization Chamber

polymer explosion-proof spray chamber

Nebulizer

atomizer efficient glass atomizer, can also be customized

Ignition Type

microcomputer control, automatic ignition

Gas Control

automatic gas control system

Detection Limits(Cu)

0.002μg/mL

Precision

RSD≤0.5%


Graphite Furnace Analytical System
 

Heating Mode

vertical heating

Temperature Control Method

vertical optical temperature monitoring graphite tube wall temperature

Temperature Range

room temperature to 3000ºC

The Program

automatic temperature control up to 20 order

Temperature Control

the furnace enriched up to 20 times

Characteristics Volume

0.4 × 10-12g (Cd)

Detection Limit

0.4 × 10-12g (Cd)

Precision

RSD≤2%

The Cooling Water

can choose cooling water circulation system

Safety

the graphite tube damage, water flow air pressure and other alarmtemperature overheating protection

One-stop Shopping

Application Field
Certifications

 

Company Profile
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

Macylab Instruments Inc. operates spectroscopic instruments, such as spectrophotometers, UV-visible spectrophotometers, atomic absorption spectrometers, ultra-micro spectrophotometers, atomic fluorescence spectrophotometers, ICP inductively coupled plasma emission spectrometers. Currently, our products have been Widely used in organic chemistry, inorganic chemistry, biochemistry, medicine, environmental protection, metallurgy, petroleum, agriculture and other fields. At the same time, the company has accumulated a wealth of experience in product mechanical structure, optical design, electrical applications and software development, combined with the latest practical needs of the market, will soon launch a number of new analytical instruments.

 

Macy's headquarter and production base is located in Shanghai, the marketing center in Beijing, and three R & D bases in Jiangsu, Shanghai, and Shandong. To take full advantage of the country's intellectual resources, MACY and the domestic and foreign research unit also conducted deep scientific research cooperation, will continue to put the research achievements into productivity .To better serve our customers, Macy has 12 domestic offices, tailored to meet the needs of your application solutions to improve the value of the products. At the same time continue to serve domestic users, Macy also with distribution in over 20 countries to establish a deep strategic partnership cooperation.
  Along with Macy accelerate the pace and rank among the global brand instruments, Macy increasing demands of our own, and we also hope to get the care and support of the community, Let us work and outlook together.Technology, will change because you and us.
 
Exhibition

 

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.


Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA