LFP-WLV5000
Li-ion Battery
LFP
Yes
Medium
Stacked
660*390*515mm
130kg
Can, RS485
Hybrid Grid
Home Solar Energy Storage System
6000 Times
Un38.3/MSDS/IEC/CE
10years
Over-Current/Over-Voltage/Short Circuit/ Under-V/O
IP65
Ground Installation
SolarEast or OEM
Wooden Box
0kwh 15kwh 20kwh 25kwh 30kwh 35kwh
China
8507600090
Product Description




Advantages
Safety:
LFP Battery, Intelligent BMS andprotective hardware providing completeprotection
Accuracy:
Accuracy:
Dynamic SOC calibration
Compatibility:
Compatibility:
Suitable for most mainstream inverters
Flexiblity:
Flexiblity:
Could be connected in parallel or series
Durability:
Durability:
6,000 cycles at 90% DOD, 15+years design life
Certificates:
Certificates:
UL,CE,IEC62619, UN38.3, MSDS


Compatible with most inverter brands on the market
Model | PowerCool-LFP-HV2-10 | PowerCool-LFP-HV2-15 | PowerCool-LFP-HV2-20 | PowerCool-LFP-HV2-25 | PowerCool-LFP-HV2-30 | PowerCool-LFP-HV2-35 |
Battery type | LFP | |||||
Number of connection | 2pcs | 3pcs | 4pcs | 5pcs | 6pcs | 7pcs |
Total energy | 10.24kWh | 15.36kWh | 20.48kWh | 25.6kWh | 30.72kWh | 35.84kWh |
Usable energy | 9.72kWh | 14.59kWh | 19.45kWh | 24.32kWh | 29.18kWh | 30.04kWh |
Max.parallel strings | 8P | |||||
Voltage | 102.4V | 153.6V | 204.8V | 256V | 307.2V | 358.4V |
Nominal charging voltage | 115.2V | 172.8V | 230.4V | 288V | 345.6V | 403.2V |
Max.charging current | 50A | |||||
Nominal discharging voltage | 50A | |||||
Discharge cut-off voltage | 89.6V | 134.4V | 179.2V | 224V | 268.8V | 313.6V |
Battery efficiency | 95% | |||||
Battery Protection | Over-current/Over-voltage/Short-circuit/Under-voltage/Over temperature | |||||
Maximum recommended DOD | 95% | |||||
Communication | RS485/CAN | |||||
IP rating | IP65 | |||||
Operating temperature | -10~50ºC | |||||
Altitude | ≤5,000m | |||||
Humidity | 5%~95% | |||||
Warranty | 5 Year Product Warranty,10 Year Performance Warranty | |||||
Dimension | 660*390*515mm | 660*390*665mm | 660*390*815mm | 660*390*965mm | 660*390*1115mm | 660*390*1265mm |
Net weight | 130kg | 180kg | 230kg | 280kg | 330kg | 380kg |
Certificates | CE-EMC,IEC62619,IEC61000,IEC62040,UN38.3,MSDS | |||||
Installation | Ground Installation | |||||
*Total Energy/Usable Energy measured under specific conditions from PowerCool-LFP 0.2C CC-CV | ||||||
Testing conditions based on temperature 25ºC at the beginning of life. |







Description
A:CHARGE
When the ON/OFF is connected (make sure the system lock is relieved via the Master software), press this button and hold for at least 10s to enter the force charging mode. At this time, the system main circuit is connected by force. Force charging mode can only be exited by disconnecting the ON/OFF,The button indicator will be ON under the force charging mode, and will be OFF when exiting the force charging mode.
When the ON/OFF is connected (make sure the system lock is relieved via the Master software), press this button and hold for at least 10s to enter the force charging mode. At this time, the system main circuit is connected by force. Force charging mode can only be exited by disconnecting the ON/OFF,The button indicator will be ON under the force charging mode, and will be OFF when exiting the force charging mode.