Surge Arrester Distribution 11kv

Price $11.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 203 people viewed
Quantity
+-
 

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
YH10W-33
Distribution
Zinc Oxide Arrester
Pole Line
AC/DC System
Meidum
High Voltage
Round
ZnO
Xihari
Oeipower Jingguan
Under 10PC
OEIpower
Cartons Pallets Wooden Case
IEC IEEE
China Nanyang
85354000
Product Description
Metal oxide surge arrester (MOA) is recognized as the upto-date overvoltage protector which ,due to the inherent superior nonlinear V-A characteristics and steep-wave response of metal oxide varistors ,can suppress overvoltages to a relative low level ,thus providing a reliable protection for insulation of electrical apparatus.
The basic technical parameters are complied with the technical specification of IEEE and IEC60099-4
arrester are heavy duty distribution class surge arrester. These are gapless design
incorporating highly non-linear metal oxide varistor, with a discharge rated current of 10 kA. The housing can be polimeric arresters are tested in accordance with the lastest standard ANSI/IEEE C62.11  for metal oxide
arresters, and also with IEC 60099-4.
They consistently withstand the following
minimum type test:
* High Current-Short duration: 2
current surges of 100 kA-crest magnitude
20 shoots of 100 kA amplitude.
* Low Current-Long duration: 20
shoots (or impulses) of 250 A amplitude
and 2.000 μs duration.
* Duty Cycle: 20 discharges with a
current surge of 10 kA magnitude and
8/20 μs wave shape followed by 2 discharges
with a current surge of 100 kA
magnitude.
 
ItemDescriptionUnits33kV



RequiredGuaranteed
Value
1Type
Metal Oxide, GaplessMetal Oxide, Gapless
2Material
PolymericPolymeric
3Nominal System Volt ratingkV3333
4Maximum System ratingkV3636
5Power FrequencyHz5050
6Peak Voltage rating: UrkV3030
7Maximum Voltage rating: UckV21kV21kV
6One minute power frequency withstand voltagekV7070
7Basic Insulation levelkVp170170
8Specific creepage distancemm/kV2525
9Nominal Discharge Current with 8/20 microsecond wavekA1010
10Fittings and Accessories
-Fasteners for stacking units along with clamp & terminal connectors.
 

 
Yes
Yes
Voltage
Rating (Ur)
(kVrms)
MCOV
(UC)1
(kVrms)
Max.
Equiv.
FOW2
(kV Crest)
Max. Switch
Surge3
(kV Crest)
Max .Discharge voltage (kV Crest)
Using 8/20 μs Current Impulse
1.5
kA
2.5 kA3.0
kA
5.0 kA10
kA
20
 kA
40
kA
32.5510.07.98.58.88.99.410.211.313.3
65.1019.915.816.917.517.718.820.422.526.6
97.6529.923.725.426.226.628.230.533.839.9
108.4032.926.328.129.229.631.333.937.443.9
1210.2039.831.633.834.935.437.640.745.053.1
1512.7049.839.542.243.644.347.050.956.366.4
1815.3059.747.450.752.353.156.461.067.579.7
2117.0069.755.359.161.062.065.771.278.792.9
2419.5079.663.267.669.770.875.181.390.0106.2
2722.0089.671.176.078.479.784.591.5101.2119.5
3024.4099.578.884.287.488.793.9101.7112.0131.7
3326.80109.586.792.696.297.6103.3111.9123.2114.9
3630.00119.494.6101.0104.9106.4112.7122.0134.4158.0
Voltage
Rating (Ur)
(kVrms)
MCOV
(UC)1
(kVrms)
Max.
Equiv.
FOW4
(kV Crest)
Max. Switch
Surge3
(kV Crest)
Max .Discharge voltage (kV Crest)
Using 8/20μs Current Impulse
1.5
kA
2.5 kA3.0
kA
5.0 kA10
kA
20
 kA
40
kA
32.5510.47.88.58.88.99.39.910.912.4
65.1020.715.516.917.517.718.619.821.824.7
97.6531.023.325.426.226.627.929.732.737.0
108.4034.525.928.229.129.531.033.036.341.1
1210.2041.331.033.834.935.437.239.643.549.3
1512.7051.738.842.243.644.246.549.554.461.6
1815.3062.046.550.752.353.155.859.465.373.9
2117.0072.354.359.161.061.965.1469.376.286.2
2419.5082.662.167.669.770.974.479.287.098.5
2722.0092.969.876.078.479.683.789.197.9110.8
3024.40103.377.684.487.188.493.099.0108.8123.1
3326.80113.785.492.895.897.3102.3108.9119.7135.4
3630.00123.993.1101.3104.5106.0111.6118.8130.6147.7
 
1.   GENERAL
Metal oxide surge arrester (MOA) is recognized as the upto-date overvoltage protector which ,due to the inherent superior nonlinear V-A characteristics and steep-wave response of metal oxide varistors ,can suppress overvoltages to a relative low level ,thus providing a reliable protection for insulation of electrical apparatus.
 
The basic technical parameters are complied with the technical specification of Chinese Standard GB11032-2000 which is exactly equivalent to IEC60099-4
2.   THCHNICAL DATA
ZINC OXIDE PROTECTIVE CHARACTERISTICS (5kA NORMAL DUTY POLYMER)
Voltage
Rating (Ur)
(kVrms)
MCOV
(UC)1
(kVrms)
Max.
Equiv.
FOW2
(kV Crest)
Max. Switch
Surge3
(kV Crest)
Max .Discharge voltage (kV Crest)
Using 8/20 μs Current Impulse
1.5
kA
2.5 kA3.0
kA
5.0 kA10
kA
20
 kA
40
kA
32.5510.07.98.58.88.99.410.211.313.3
65.1019.915.816.917.517.718.820.422.526.6
97.6529.923.725.426.226.628.230.533.839.9
108.4032.926.328.129.229.631.333.937.443.9
1210.2039.831.633.834.935.437.640.745.053.1
1512.7049.839.542.243.644.347.050.956.366.4
1815.3059.747.450.752.353.156.461.067.579.7
2117.0069.755.359.161.062.065.771.278.792.9
2419.5079.663.267.669.770.875.181.390.0106.2
2722.0089.671.176.078.479.784.591.5101.2119.5
3024.4099.578.884.287.488.793.9101.7112.0131.7
3326.80109.586.792.696.297.6103.3111.9123.2114.9
3630.00119.494.6101.0104.9106.4112.7122.0134.4158.0
 
High-Current Short Duration: 2 current surges of 65kA magnitude and  4/10μs wave shape.
Low-Current Long Duration : 20 current surges of 75 A magnitude and 2000μs duration .
1 MCOV=Maximum Continuous Operating Voltage that may be applied continuously between the terminals of the arrester.
2 The equivalent Front-of -Wave is the maximum discharge voltage for a 5kA impulse current wave which produces a voltage wave cresting in 0.35μs. 
3 Based on a switching surge current impulse of 45×90μs, 500 amperes.
4 The equivalent Front-of-Wave is the maximum discharge voltage for a 10kA impulse current wave which produces a voltage wave cresting in 0.5μs.
ZINC OXIDE PROTECTIVE CHARACTERISTICS (10kA NORMAL DUTY POLYMER)
 
Voltage
Rating (Ur)
(kVrms)
MCOV
(UC)1
(kVrms)
Max.
Equiv.
FOW4
(kV Crest)
Max. Switch
Surge3
(kV Crest)
Max .Discharge voltage (kV Crest)
Using 8/20μs Current Impulse
1.5
kA
2.5 kA3.0
kA
5.0 kA10
kA
20
 kA
40
kA
32.5510.47.88.58.88.99.39.910.912.4
65.1020.715.516.917.517.718.619.821.824.7
97.6531.023.325.426.226.627.929.732.737.0
108.4034.525.928.229.129.531.033.036.341.1
1210.2041.331.033.834.935.437.239.643.549.3
1512.7051.738.842.243.644.246.549.554.461.6
1815.3062.046.550.752.353.155.859.465.373.9
2117.0072.354.359.161.061.965.1469.376.286.2
2419.5082.662.167.669.770.974.479.287.098.5
2722.0092.969.876.078.479.683.789.197.9110.8
3024.40103.377.684.487.188.493.099.0108.8123.1
3326.80113.785.492.895.897.3102.3108.9119.7135.4
3630.00123.993.1101.3104.5106.0111.6118.8130.6147.7
 
 
High-Current Short Duration: 2 current surges of 65kA magnitude and  4/10μs wave shape.
Low-Current Long Duration : 20 current surges of 75 A magnitude and 2000μs duration .
1 MCOV=Maximum Continuous Operating Voltage that may be applied continuously between the terminals of the arrester.
2 The equivalent Front-of -Wave is the maximum discharge voltage for a 5kA impulse current wave which produces a voltage wave cresting in 0.5μs. 
3 Based on a switching surge current impulse of 45×90μs, 500 amperes.
4 The equivalent Front-of-Wave is the maximum discharge voltage for a 10kA impulse current wave which produces a voltage wave cresting in 0.5μs.
 
 
 
 
 
3.APPLICATION CONDITION
3.1 Normal Service condition
Surge arresters which conform to this standard shall be suitable for normal operation under the following normal service conditions:
  Ambient air temperature within the range of -40ºC to +40ºC.
  Solar radiation :
  The effects of maximum solar radiation (1.1kW/m2)have been taken into account by preheating the test specimen in the type tests. If there are other heat sources near the arrester, the application of the arrester shall be subject to an agreement between the manufacturer and the purchaser.
  Altitude is not exceeding 1000m.
  Frequency of the A.C power supply is not less than 48Hz but not more than 62HZ.
  Power frequency voltage applied continuously between the terminals of the arrester is not exceeding its continuous operating voltage.
  Mechanical conditions ;no strong vibration.
  Pollution conditions: no requirement at this time.
 
3.2 Abnormal Service Conditions
Surge arresters subject to other than normal application or service conditions may require special consideration in design, manufacture or application. The use of this standard in case of abnormal service conditions is subject to agreement between the manufacturer and the purchaser.
 
4 OVERALLDIMENSIONS  

5kA NORMAL DUTY POLYMER
Rated
Voltage
36910121518212427303336
A98mm
B                             68mm
C200246246246246302350350350420420480480
D                             138mm
Creepage
Distance
1803903903903655006606607008908909701100
 
 
10kA NORMAL DUTY POLYMER
Rated
Voltage
36910121518212427303336
A                             106mm
B                             78mm
C200246246246246302350350350420420480480
D                            138mm
Creepage
Distance
1803903903903655006606607008908909701100
 
5. INSTALLATION AND PRECAUTION
5.1 The surge arrester is fixed to the supporting structure by fitting-bracket, and connecting its top terminal to H V wire of electrical apparatus ,which is protected ,with 8-16 mm2 copper wire, connecting its chassis cover to the terminal of operation counter, connecting the other terminal of operation counter to the ground wire, or connecting its chassis cover to the ground directly.
5.2 The surge arrester should be lain close to the electrical apparatus, which is protected ,for protective effects. When the transformer is protected ,the distance between the arrester and on the low voltage side of a distribution transformer in case any damage to the insulation caused by forward-backward over voltage
5.3 After bring the surge arrester into operating ,should be do preventive test every two years, measuring the leakage current of arrester at DA 1mA.
5.4 Please don't break open the surge arresters.
5.5 This product is warranted against defects in workmanship and materials .If any failure ,resulting from a defect in either workmanship or material, is occurred under the normal using within one years form the date of purchase ,we shall replace it in free of charge.              
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA