CWM-303
Anaesthesia Machine
Medical Equipment
CE, ISO13485
Adult, Pediatric and Infants
With LCD Display
15 Inch
Electronic Control, Pneumatic Driven
CE and ISO
1
CW
Standard Export Packing
ISO, CE
China
90189070
Product Description
Anaesthesia Machine (CWM-303):

Main specification:
Power: AC 220V ± 10%, 50Hz ± 2%, built-in battery for backup
Tital Volume range: 10-1500ml
I:E range: 4:1-1:8
Gas: O2 , N2O, air
Pipeline input range: 280-600kPa
Run-time: >=180min
Oxygen flush: 25 to 75L/minute
Vaporizers: 2 selectetac, maximum 2 mounts(Isoflurane/ Enflurane/ Sevoflurane/ Halothane)
Parameters monitoring: Tidal volume, minute volume, frequency, airway pressure, O² Concentration, lung compliance (optional)
Display graphics: Waveforms of P-T, F-T, V-T, loops of P-V, V-F, F-P (Zoom in/out, comparison, freeze)
Types: VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform, FiO2
Alarm: No tital volume, MV, Paw, FiO2 limitation O2 , Air faliture, AC power faliture, Battery low.
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.



Model | CWM-303 |
Applied for | adult and children |
Power: | 220V AC ± 10%, 50Hz ± 2%, built-in battery for backup |
Gas: | O2 , N2O, air |
Oxygen flush: | 25 to 75L/minute |
Ventilation modes: | VCV, PCV, PSV, SIMV-V, SIMV-P, PA-VC. |

15 inch touch screen.
Applied for adult, pediatric and infants.
Compact anesthesia ventilation system.
Apply quick automatic compensation function for VT.
Easy to operate, user friendly for inhalation anesthesia.
Real-time detection for loops, Paw, BPM, VT and compliance.
Ventilation modes: VCV, PCV, PSV, SIMV-V, SIMV-P, PA-VC.
Breathing loops with zoom in/ out, freeze and comparison. 72 hrs trends records with 3000 logs.
Applied for adult, pediatric and infants.
Compact anesthesia ventilation system.
Apply quick automatic compensation function for VT.
Easy to operate, user friendly for inhalation anesthesia.
Real-time detection for loops, Paw, BPM, VT and compliance.
Ventilation modes: VCV, PCV, PSV, SIMV-V, SIMV-P, PA-VC.
Breathing loops with zoom in/ out, freeze and comparison. 72 hrs trends records with 3000 logs.
Main specification:
Power: AC 220V ± 10%, 50Hz ± 2%, built-in battery for backup
Tital Volume range: 10-1500ml
I:E range: 4:1-1:8
Gas: O2 , N2O, air
Pipeline input range: 280-600kPa
Run-time: >=180min
Oxygen flush: 25 to 75L/minute
Vaporizers: 2 selectetac, maximum 2 mounts(Isoflurane/ Enflurane/ Sevoflurane/ Halothane)
Parameters monitoring: Tidal volume, minute volume, frequency, airway pressure, O² Concentration, lung compliance (optional)
Display graphics: Waveforms of P-T, F-T, V-T, loops of P-V, V-F, F-P (Zoom in/out, comparison, freeze)
Types: VT, MV, BPM, Paw, Lung compliance, Inspiratory Platform, FiO2
Alarm: No tital volume, MV, Paw, FiO2 limitation O2 , Air faliture, AC power faliture, Battery low.
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.



