Swimming Pool Water Heater Heat Pump

Price $8000.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 440 people viewed
Quantity
+-
 

Shenzhen Eurostars Technology Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
ESSA-12.5HP(2*6HP)
ISO9001, CE
R410A
Air Source Heat Pump
Copeland/Panasonic
Titanium Tube-in-Shell Heat Exchanger
Blue Aluminum Fin Copper Tube
Optional
-7deg C~43deg C
2 Years, 18 Months, 1 Year
Available
Electric Expansion Valve
50Hz, 60Hz(Optional)
Available
Electric
Galvanized Steel
Monoblock Type
Pool Water Cooling and Heating
R410A
ESACIR
Standard Export Package
CE
Guangdong, China
8418692090
Product Description
1.Application of Air Source Swimming Pool Heat Pump
Eurosatrs House Spa and Commercial Swimming Pool Heat pump are specially developed for commercial pool or spa water temperature control. With intelligent control system are let the units high efficiency and stable working performance. The COP of this type heat pump can reach 5~ 5.4 at some working condition, which saves you at least 80% energy;Suitable for large pools in hotel, public parks, schools, sport center, gyms, house spa, etc.


2.Eurostars Air Source Swimming Pool Heat Pump Features:
Eurosatrs Swimming Pool Air Source Heat Pumps are designed for commercial pool water heating. They have the following important features:
--Constant pool water temperature;
--Absorb heat from the air with high COP;
--Working air temperature range: -7ºC to 43ºC;
--Automatic control of pool water temperature;
--Max outlet water temperature: 40ºC;
--Guaranteed safety: water and electricity are isolated;
--Anti-corrosion with Titanium tube-in-shell heat exchanger;
--Save 65%-80% of the operating costs without pollution to the environment.
--Automatic and forced defrosting function; 
--Multiple protections


3. Air Source Swimming Pool Heat Pump Technical Data
Air Source Heat Pump Unit(Swimming Pool Heat Pump)
ModelESSA-05HPESSA-05HPESSA-05HPESSA-05HP
2.5ES3.5ES4.5ES3.5ES
Heating Air DB/WB: 24ºC/16ºC
Water tempt: 28ºC
KW10.215.118.515.1
x 1000 Kcal/h8.813.015.913.0
RT2.94.35.34.3
Input power (KW)1.942.953.602.94
COP5.265.125.145.14
Cooling Air DB/WB: 35ºC/24ºC
Water tempt: 28ºC
KW6.69.812.09.8
x 1000 Kcal/h5.78.410.38.4
RT1.92.83.42.8
Input power (KW)2.113.213.923.20
EER3.143.063.073.07
Compressor TypeHermetic Scroll
Throttle TypeExpansion Valve
Refrigerant R410A
Power Supply220~240V/50Hz380~420V/50Hz
       
ModelESSA-05HPESSA-10HPESSA-10HPESSA-12.5HP
4.5ES6ES2*4.5ES2*6ES
Heating Air DB/WB: 24ºC/16ºC
Water tempt: 28ºC
KW20.226.140.452.2
x 1000 Kcal/h17.422.434.744.9
RT5.77.411.514.8
Input power (KW)3.965.117.9210.22
COP5.105.115.105.11
Cooling Air DB/WB: 35ºC/24ºC
Water tempt: 28ºC
KW13.117.026.333.9
x 1000 Kcal/h11.314.622.629.2
RT3.74.87.59.7
Input power (KW)4.315.568.6211.12
EER3.053.053.053.05
Compressor TypeHermetic Scroll
Throttle TypeExpansion Valve
Refrigerant R410A
Power Supply380~420V/50Hz
       
ModelESSA-15HPESSA-20HPESSA-25HP 
2*7ES4*4.5ES4*6ES 
Heating Air DB/WB: 24ºC/16ºC
Water tempt: 28ºC
KW60.580.8104.4 
x 1000 Kcal/h52.069.589.8 
RT17.223.029.7 
Input power (KW)11.9415.8420.44 
COP5.075.105.11 
Cooling Air DB/WB: 35ºC/24ºC
Water tempt: 28ºC
KW39.352.567.9 
x 1000 Kcal/h33.845.258.4 
RT11.214.919.3 
Input power (KW)12.9917.2322.24 
EER3.033.053.05 
Compressor TypeHermetic Scroll
Throttle TypeExpansion Valve
Refrigerant R410A
Power Supply380~420V/50Hz
4.Air Source Swimming Pool Heat Pump Main Components Introduction
1) Base frame and external panels are made of galvanized sheet.
2) High efficiency compressor with R410A Refrigerant.

3) Touch design LCD control panel, and the control signals are easier to be transferred to the control system;
4) Openable cabinet door design for faster and simpler checking and maintenance
5) Well heat insulation inside the unit to increase the COP.
6) Exterior rotor fan ensures lower noise and vibration
7) Lovely outlook and sharp edges reduction cabinet design
8) High quality copper tube coils constructed of thread technology
9) Automatic defrosting function included.
10) Clock & Timing on/off function.
11) General testing and operational test carried out for every unit before package in the factory.
12) With full protection functions including water flow, high/low pressure, phase order, over-current etc.
13) Big evaporator to extract more heat from the air.

14) Metal Galvanized powder coated frame
15) For low temperature area: -25ºC(optional);


5. EUROSTARS Air Source Scroll Heat Pump Range:
(1) Water source heat pump
(2) Geothermal source heat pump
(3) Air source heat pump, including swimming pool heat pump
(4) EVI air source heat pump
(5) Split heat pump
(6) DC Inverter heat pump

6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services;
One Stop Solution For Your Project:
-- Project Consultation
--Professional Customized Design & Planning
--Supply Full Set Optimum Equipment & Accessary Accordingly
--Whole Project Installation & Commissioning
--Project Running Management, Engineer and Operator Training, Turnkey
--Long Life Quality Assurance & Maintenance



7.FAQ
Q:How does the Swimming Pool Heat Pump Work?
Heat pumps use a small amount of driven electricity to absorb heat and transport it from one place to another. Indeed, they couldn't generate heat. 

As swimming pool's water circulated by the pool pump, the water get from the pool passes through a filter and pool heater. The pool heater has a fan that brings in the outside air and guides it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside and then evaporate gas. The evaporated gas in the coil then flows through the compressor. The compressor pump to increase the heat, generate a very hot gas that then flows through the condenser. The condenser moves the heat from the hot gas to heat the cooler pool water circulating through the heater. The heated water then flow into the pool. The hot gas, as cross flows through the condenser coil, back to liquid form and return the evaporator, where the whole process begins again. 

Higher efficiency heat pump pool heaters usually use scroll compressors versus the rotary compressors of standard composition. 

Heat pump pool heaters work efficiently as long as the outside temperature remains above the 7ºC-10ºC range. The cooler the outside air they bring in, the more energy they exhaust. However, since most people adopt outdoor swimming pools during summer or mild weather, this usually isn't an issue.


8.Customer visit us

9.Air source heat pump delivery or container loading


10.Installation instruction or installation photo, project photos


A,Place selection of installation Heat pump

 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.



 
Message Type