Syringe Pump Am-602 ICU Medical Equipment Manufacturer Portable Micro Volume Pump Syringe Driver with Ce, ISO

Price $500.00 Compare
Min Order 1 Set
Shipping From Jiangsu, China
Popularity 228 people viewed
Quantity
+-
 

Nanjing AMIS Medical Technology Co., Ltd.

VIP   Audited Supplier 16 years
Profile Certified by SGS/BV
AM-602
Infusion Pump
Plastic
Optional
Medical
Reusable
CE, ISO13485
All
Without Needle
Pumping Water
Single
AMISMED
Carton
China
9018390000
Product Description



 

 

Characteristics





1. Applicable syringe: 12 brands for user-defined
2. Occlusion sensitivity: adjustable
3. Can be stacked up and integrated into multi-channel
4. Syringe size: 10, 20, 30, 50 ml
5. Accuracy: ±2%
6. Flow rate: 0.1-1300 ml/h
7. KVO rate: 0.1-1 ml/h in 0.1 ml/h increments, adjustable



 
Specification:
Model
AM-602 syringe pump
Syringe Size
10, 20, 30, 50 ml
Applicable Syringe
2 brands built-in (BD, B. Braun), 10 brands for user-defined
Volume
0.1- 9999 ml
<1000 ml in 0.1 ml increments
≥1000 mL in 1 ml increments
Flow Rate
Syringe 10 ml: 0.1- 400 ml/h
Syringe 20 ml: 0.1- 600 ml/h
Syringe 30 ml: 0.1- 900 ml/h
Syringe 50 ml: 0.1-1300 ml/h
<100 ml/h in 0.1 ml/h increments or decrements
≥100 ml/h in 1 ml/h increments or decrements
Bolus Rate
Syringe 10 ml: 400 ml/h
Syringe 20 ml: 600 ml/h
Syringe 30 ml: 900 ml/h
Syringe 50 ml: 1300 ml/h
Accuracy
±2%
Infusion Mode
Flow rate: ml/min, ml/h
Time-based
Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h
KVO Rate
0.1 -1ml/h in 0.1 ml/h increments or decrements, adjustable
Alarms
Occlusion, syringe drop off, near empty, end program, low pressure, end battery, AC power off, motor malfunction, unattended pump,
syringe moved accidently, pressure sensor error
Additional Features
Syringe identification, bolus, real-time shift totals, occlusion pressure release, mute, automatic power switching, residue
reminder, system memory
Occlusion Sensitivity
High: 0.02-0.06 Mpa
Medium: 0.06-0.09 Mpa
Low: 0.09-0.12 MPa
Power Supply, AC
110/230 V (optional), 50/60 Hz, 20 VA
Battery
9.6 ±1.6 V, rechargeable
Battery Life
5 hours at 5 ml/h
Working Temperature
5- 40°C
Relative Humidity
20-90%
Atmospheric Pressure
860-1060 hpa
Size
314*167*140 mm
Weight
2.5 kgs
Safety Classification
Class II, type CF








  • Hospital Infant Radiant Warmer Neonate Bilirubin Phototherapy Equipment Transport Baby Warmers
    Hospital Infant Radiant Warmer Neonate Bilirubin Phototherapy Equipment Transport Baby Warmers
Message Type
* Message Content
* Name  
* Phone
* Email