RH-M0050-S1-PH60-A01B-S0-CN
Magnetostrictive Displacement Sensor
Analog Type
Linear Displacement
SemiConductor Integrated
Metal
16-Bit D/a or 0.0015% of Full Scale (Min 1um)
IP67
CE
Customized
25~5500 mm
Analog Current or Voltage
1 ~ 100 μm, Adjustable
<±0.01% of Full Scale
<±0.001% of Full Scale
<10μm
<15ppm/ºC
Arbitrary
IP67rh Stainless Steel Rod
-40ºC ~ +85ºC
35MPa (Continuous)/70MPa (Peak)
+24VDC±20%
<80mA (Varying with Range)
Max.-30VDC
Max.36VDC
TEC Sensors
Paper Tube
China
90318090
Product Description
Output: | Analog Output |
Measuring length: | 25~5500 mm,customized according to customer needs |
Repeat accuracy: | <±0.001% of full scale, min ±1um |
Non-linearity: | <±0.01% of full scale, min±50um |
Operating voltage Ub: | +24Vdc ± 20% |
Ambient temperature: | -40ºC ~ +85ºC(up to105ºC) |
Mechanical configuration: | Fastening M20 threads, Fastening M18 threads, Fastening 3/4" threads |
Housing material: | Aluminum alloy |
IP rating: | IP65 |
Approval/Conformity: | CE |
Analog output magnetostrictive displacement sensor, suitable for real-time and precise measurement of moving parts stroke, it can measure the absolute displacement or stroke of vernier magnet, expressed in the form of standard analog quantity, including: 0~20mA (or reverse), 4~20mA
(or reverse) DC current or 0~5V (or reverse),-5~+5V (or reverse), 0~10V (or reverse),-10~+10V (or reverse) DC voltage, etc. Sensors have built-in and external two different installation methods, built-in type is suitable for the built-in installation of hydraulic cylinders, compact structure; the external type adopts aluminum profile, which is installed outside the moving parts and convenient to use.




RH series pressure-resistant rodshell, built-in installation design for hydraulic system, pressure-resistant 35MPa continuous, flexible and simple
installation mode.Mounting thread form M18×1.5 or M20×1.5 or 3/4"-16UNF-3A.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default values of the first and last measurement Non-usable areas of this product are 50.8mm and 63.5mm respectively. The value of the measurement Non-usable area can be appropriately modified according to the needs of customers, please pointed out when ordering.