GF312V2
24 Hours Online
Three Years
Mechanical Instrument, Electromagnetic Instrument
Electricity
With LCD Display
Customized
Three Phase Energy Meter Field Calibrator
0.05%,0.1%
12mm or 18mm
0.01%/Minute
25000
GFUVE
Standard Export Carton
CE
Beijing, China
Product Description
Three Phase Energy Meter Test Field Calibrator


GF312V2 portable three phase multifunction energy meter calibrator is with human oriented design, small configuration and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
Features
High accuracy 0.05%
Screen copy function
Input two pulse signal for master and slave meter synchronously calibration
Large size display screen, direct viewing and convenient
Internal communication port for PC control
Multi power supply ways for different testing occasion
Large capacity storage device for mass memory







GF312V2 portable three phase multifunction energy meter calibrator is with human oriented design, small configuration and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
Features
High accuracy 0.05%
Screen copy function
Input two pulse signal for master and slave meter synchronously calibration
Large size display screen, direct viewing and convenient
Internal communication port for PC control
Multi power supply ways for different testing occasion
Large capacity storage device for mass memory
Test Voltage | |
Range | 30-560V |
Error | ± 0.05% |
Harmonic | 2 nd -- 51 st |
Test Current | |
Range (direct connection) | 0.01-10A |
Range (clamp CT) | 100A 5A, 500A, 1000A, 2000A (option) |
Error (direct connection) | ± 0.05% |
Error (clamp CT) | ± 0.2% (5A, 100A ) ± 0.5% (other) |
Harmonic | 2 nd -- 51 st |
Power measure error | |
Active power (direct connection) | ± 0.05% |
Active power (clamp CT) | ± 0.2% (5A, 100A) ± 0.5% (other) |
Reactive power (direct connection) | ± 0.1% |
Reactive power (clamp CT) | ± 0.2% (5A, 100A) ± 0.5% (other) |
Energy measure error | |
Active energy (direct connection) | ± 0.05% |
Active energy (clamp CT) | ± 0.2% (5A, 100A) ± 0.5% (other) |
Reactive energy (direct connection) | ± 0.1% |
Reactive energy (clamp CT) | ± 0.2% (5A, 100A) ± 0.5% (other) |
Phase angle | |
Range | 0º - 360º |
Error | ± 0.05º |
Frequency | |
Range | 45Hz - 65Hz |
Pulse output | |
Energy constant | 1~25000imp/kWh |
Pulse ratio | 1: 1 |
Output level | 5V |
Pulse input | |
Input channel | 2 |
Input level | 5 -- 10V |
Input frequency | Max. 100Hz |
Display | |
Resolution | 7" TFT color (480× 234) |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
CT ratio test | Yes |
Local parameter input | Yes |
Wiring emulation | Yes |
Self-calibration | Yes |
Recorder check | Yes |
Data storage | Yes |
Data storage qty | 5000 |
External extend memory | Yes |
Screen printing | Yes |
Communication port | USB/RS232 |
Communication with PC | Yes |
Upload data | Yes |
External mini printer | Yes |
External keyboard | Yes |
Other | |
Voltage Supply way | External power test lead power |
Voltage Supply | 45-450V, 50/60Hz |
Ambient temperature | -25-- +45degrees |
Relative humidity | 30% -- 95% |
Dimensions (W × H × D) (mm) | 245× 168× 70 |
Weight (kg) | 1.8kg |